Design and performance of a plasma-source mass spectrograph

被引:62
|
作者
Burgoyne, TW
Hieftje, GM
Hites, RA
机构
[1] INDIANA UNIV,DEPT CHEM,BLOOMINGTON,IN 47405
[2] INDIANA UNIV,SCH PUBL & ENVIRONM AFFAIRS,BLOOMINGTON,IN 47405
基金
美国国家卫生研究院;
关键词
D O I
10.1016/S1044-0305(96)00290-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A plasma-source, simultaneously detecting, Mattauch-Herzog mass spectrograph for multielement analysis was developed. Simultaneous detection should improve throughput, precision, and sensitivity over those instruments that use quadrupole or sector mass spectrometers. The new instrument is compact (approximately 80 cm in length) and is designed to detect a complete atomic mass spectrum in two mass windows that straddle but avoid argon. The design and some figures of merit are presented. With a dc glow discharge source, a precision of 0.5% determined from eight consecutive 10-s images was obtained for Cu isotope ratios in Naval Brass B. With the same sample, nickel and lead were detected at limits of 8 and 1 ppm. Measured Mg isotope ratios with an inductively coupled plasma source were within 4% of the expected values. The resolution at full width at half maximum is currently limited to approximately 60, in part because of poor peak shape. The origin of this peak shape has been determined to lie within the array detector and possibly results from its interaction with the fringing magnetic fields produced by the second sector. (C) 1997 American Society for Mass Spectrometry.
引用
收藏
页码:307 / 318
页数:12
相关论文
共 50 条
  • [31] Surface analysis of polymers electrically improved by plasma-source ion-implantation
    Lee, Y
    Han, S
    Lim, H
    Kim, Y
    Kim, H
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 373 (07) : 595 - 600
  • [32] Microstructure and composition of InAsN alloys grown by plasma-source molecular beam epitaxy
    Beresford, R.
    Stevens, K.S.
    Schwartzman, A.F.
    Journal of Vacuum Science & Technology B: Microelectronics Processing and Phenomena, 1998, 16 (03):
  • [33] Design and Performance of the ICON EUV Spectrograph
    Sirk, Martin M.
    Korpela, Eric J.
    Ishikawa, Yuzo
    Edelstein, Jerry
    Wishnow, Edward H.
    Smith, Christopher
    McCauley, Jeremy
    McPhate, Jason B.
    Curtis, James
    Curtis, Travis
    Gibson, Steven R.
    Jelinsky, Sharon
    Lynn, Jeffrey A.
    Marckwordt, Mario
    Miller, Nathan
    Raffanti, Michael
    Van Shourt, William
    Stephan, Andrew W.
    Immel, Thomas J.
    SPACE SCIENCE REVIEWS, 2017, 212 (1-2) : 631 - 643
  • [34] DESIGN AND PERFORMANCE OF THE ARGONNE BIOLOGICAL SPECTROGRAPH
    EHRET, CF
    MONK, GS
    RADIATION RESEARCH, 1955, 3 (02) : 223 - 223
  • [35] Characteristics of a rf-only hexapole ion-guide interface for plasma-source time-of-flight mass spectrometry
    Guzowski, JP
    Hieftje, GM
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (08) : 781 - 792
  • [36] DESIGN AND PERFORMANCE OF THE DUAL GRATING SPECTROGRAPH
    MELTZER, RJ
    ANALYTICAL CHEMISTRY, 1955, 27 (07) : 1204 - 1204
  • [37] Hanle echelle spectrograph: design and performance
    Sriram, S.
    Kumar, Amit
    Surya, Arun
    Sivarani, T.
    Giridhar, Sunetra
    Kathiravan, S.
    Anand, M. N.
    Jones, Damien
    Grobler, Deon
    Jakobsson, Robert
    Chanumolu, Anantha
    Unni, Athira
    Dorje, Angchuk
    Dorje, Tsewang
    Gyalson, Tsewang
    GROUND-BASED AND AIRBORNE INSTRUMENTATION FOR ASTRONOMY VII, 2018, 10702
  • [38] Design and Performance of the ICON EUV Spectrograph
    Martin M. Sirk
    Eric J. Korpela
    Yuzo Ishikawa
    Jerry Edelstein
    Edward H. Wishnow
    Christopher Smith
    Jeremy McCauley
    Jason B. McPhate
    James Curtis
    Travis Curtis
    Steven R. Gibson
    Sharon Jelinsky
    Jeffrey A. Lynn
    Mario Marckwordt
    Nathan Miller
    Michael Raffanti
    William Van Shourt
    Andrew W. Stephan
    Thomas J. Immel
    Space Science Reviews, 2017, 212 : 631 - 643
  • [39] MULTI-ELEMENTAL ANALYSIS OF HUMAN-MILK BY INDUCTIVELY COUPLED PLASMA-SOURCE MASS-SPECTROMETRY - IMPLICATIONS FOR INFANT HEALTH
    DURRANT, SF
    WARD, NI
    JOURNAL OF MICRONUTRIENT ANALYSIS, 1989, 5 (02): : 111 - 126
  • [40] USE OF THE THOMSON MASS SPECTROGRAPH FOR LASER PLASMA INVESTIGATION
    VOLOVSKI, E
    VORYNA, E
    DENUS, S
    EROKHIN, AA
    ZAKHARENKOV, YA
    MROZ, V
    SKLIZKOV, GV
    FARNY, Y
    SHIKANOV, AS
    ZHURNAL TEKHNICHESKOI FIZIKI, 1982, 52 (02): : 366 - 373