Design and performance of a plasma-source mass spectrograph

被引:62
|
作者
Burgoyne, TW
Hieftje, GM
Hites, RA
机构
[1] INDIANA UNIV,DEPT CHEM,BLOOMINGTON,IN 47405
[2] INDIANA UNIV,SCH PUBL & ENVIRONM AFFAIRS,BLOOMINGTON,IN 47405
基金
美国国家卫生研究院;
关键词
D O I
10.1016/S1044-0305(96)00290-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A plasma-source, simultaneously detecting, Mattauch-Herzog mass spectrograph for multielement analysis was developed. Simultaneous detection should improve throughput, precision, and sensitivity over those instruments that use quadrupole or sector mass spectrometers. The new instrument is compact (approximately 80 cm in length) and is designed to detect a complete atomic mass spectrum in two mass windows that straddle but avoid argon. The design and some figures of merit are presented. With a dc glow discharge source, a precision of 0.5% determined from eight consecutive 10-s images was obtained for Cu isotope ratios in Naval Brass B. With the same sample, nickel and lead were detected at limits of 8 and 1 ppm. Measured Mg isotope ratios with an inductively coupled plasma source were within 4% of the expected values. The resolution at full width at half maximum is currently limited to approximately 60, in part because of poor peak shape. The origin of this peak shape has been determined to lie within the array detector and possibly results from its interaction with the fringing magnetic fields produced by the second sector. (C) 1997 American Society for Mass Spectrometry.
引用
收藏
页码:307 / 318
页数:12
相关论文
共 50 条
  • [21] Which way for Os? A comparison of plasma-source versus negative thermal ionisation mass spectrometry for Os isotope measurement
    Pearson, DG
    Ottley, CJ
    PLASMA SOURCE MASS SPECTROMETRY: THE NEW MILLENNIUM, 2001, (267): : 279 - 287
  • [22] RAPID MULTIELEMENTAL ANALYSIS OF CHINESE REFERENCE SOILS BY LASER ABLATION INDUCTIVELY COUPLED PLASMA-SOURCE MASS-SPECTROMETRY
    DURRANT, SF
    WARD, NI
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 345 (07): : 512 - 517
  • [23] Computer simulations of laser ablation sample introduction for plasma-source elemental microanalysis
    Bleiner, Davide
    Bogaerts, Annemie
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2006, 21 (11) : 1161 - 1174
  • [24] Plasma-source ion implantation compared with glow-discharge plasma nitriding of stainless steel
    Günzel, R
    Betzl, M
    Alphonsa, I
    Ganguly, B
    John, PI
    Mukherjee, S
    SURFACE & COATINGS TECHNOLOGY, 1999, 112 (1-3): : 307 - 309
  • [25] Surface analysis of polymers electrically improved by plasma-source ion-implantation
    Yeonhee Lee
    Seunghee Han
    Hyuneui Lim
    Youngwoo Kim
    Haidong Kim
    Analytical and Bioanalytical Chemistry, 2002, 373 : 595 - 600
  • [26] NUMERICAL-SIMULATION OF PLASMA SHEATH EXPANSION, WITH APPLICATIONS TO PLASMA-SOURCE ION-IMPLANTATION
    EMMERT, GA
    HENRY, MA
    JOURNAL OF APPLIED PHYSICS, 1992, 71 (01) : 113 - 117
  • [27] Plasma-Source High-Resolution XUV Spectroscopy as Complementary to Beamlines Limitations
    Barbato, F.
    Bleiner, D.
    X-RAY LASERS 2016, 2018, 202 : 29 - 35
  • [28] Microstructure and composition of InAsN alloys grown by plasma-source molecular beam epitaxy
    Beresford, R
    Stevens, KS
    Schwartzman, AF
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1998, 16 (03): : 1293 - 1296
  • [29] MULTIELEMENT ANALYSIS OF NATURAL-WATER USING INDUCTIVELY COUPLED PLASMA-SOURCE MASS-SPECTROMETRY (ICP-MS)
    WARD, NI
    WATERSHED 89 : THE FUTURE FOR WATER QUALITY IN EUROPE, VOLS 1 AND 2, 1989, : 197 - 204
  • [30] MAGNESIUM ION SOURCE FOR HIGH INTENSITY MASS SPECTROGRAPH
    PI, TH
    PHYSICAL REVIEW, 1945, 67 (1-2): : 65 - 65