Design and characterization of Kenics static mixer crystallizers

被引:22
|
作者
Thomas, Kiran Mathew [1 ]
Nyande, Baggie W. [1 ]
Lakerveld, Richard [1 ]
机构
[1] Hong Kong Univ Sci & Technol, Dept Chem & Biol Engn, Clear Water Bay, Hong Kong, Peoples R China
来源
关键词
Crystallization; Static mixer; Continuous crystallization; CFD; Lysozyme; 3D printing; FLOW TUBULAR CRYSTALLIZATION; RESIDENCE TIME DISTRIBUTION; NATURAL COOLING MODE; PRESSURE-DRIVEN FLOW; PARTICLE MIGRATION; PROTEIN CRYSTALLIZATION; PROCESS INTENSIFICATION; BATCH CRYSTALLIZATION; SECONDARY NUCLEATION; POLYMORPH SELECTION;
D O I
10.1016/j.cherd.2022.01.025
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Tubular crystallizers are desirable for continuous operations because they can approach plug flow conditions, achieve higher throughputs, and can be easy to control. However, the possible limitations of tubular crystallizers may include settling of crystals, fouling and higher pressure drops at longer residence times. The performance of a tubular crystallizer with gaps between the Kenics type mixing elements is characterized and compared with a standard Kenics static mixer and a hollow tubular crystallizer for the crystallization of lysozyme from solution. The gapped Kenics static mixer crystallizer provides an attractive trade-off between the standard Kenics static mixer and the hollow tubular crystallizer in terms of mixing length, shear rate, residence time distribution, pressure drop and segregation or settling of crystals. Furthermore, the gapped Kenics static mixer crystallizer and the standard Kenics static mixer crystallizer exhibit a similar crystallization performance in terms of desupersaturation profile and mean crystal size at the outlet for different initial lysozyme concentrations and seed loadings. The advantages of the gapped Kenics static mixer crystallizer in terms of pressure drop and minimization of crystal settling allow for lower flow rates and longer residence times under plug flow conditions, which has important practical benefits for continuous crystallization. (c) 2022 Published by Elsevier Ltd on behalf of Institution of Chemical Engineers.
引用
收藏
页码:549 / 563
页数:15
相关论文
共 50 条
  • [41] Mixing performance of viscoelastic fluids in a Kenics KM in-line static mixer
    Ramsay, J.
    Simmons, M. J. H.
    Ingram, A.
    Stitt, E. H.
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2016, 115 : 310 - 324
  • [42] LARGE EDDY SIMULATION OF TURBULENT FLOW AND HEAT TRANSFER IN A KENICS STATIC MIXER
    Murasiewicz, Halina
    Zakrzewska, Barbara
    CHEMICAL AND PROCESS ENGINEERING-INZYNIERIA CHEMICZNA I PROCESOWA, 2019, 40 (01): : 87 - 99
  • [43] An experimental investigation of the non-Newtonian liquid flow in a Kenics static mixer
    Adamiak, I
    Jaworski, Z
    INZYNIERIA CHEMICZNA I PROCESOWA, 2001, 22 (3B): : 175 - 180
  • [44] Large eddy simulations of the newtonian fluid flow through a kenics static mixer
    Peryt-Stawiarska, Sylwia
    Jaworski, Zdzislaw
    Chemical and Process Engineering - Inzynieria Chemiczna i Procesowa, 2007, 28 (03): : 435 - 444
  • [45] EXPERIMENTAL INVESTIGATION OF MASS-TRANSFER AND FLOW RESISTANCE IN KENICS STATIC MIXER
    MORRIS, WD
    MISSON, P
    INDUSTRIAL & ENGINEERING CHEMISTRY PROCESS DESIGN AND DEVELOPMENT, 1974, 13 (03): : 270 - 275
  • [46] Large eddy simulations of the newtonian fluid flow through a kenics static mixer
    Peryt-Stawiarska, Sylwia
    Jaworski, Zdzislaw
    INZYNIERIA CHEMICZNA I PROCESOWA, 2007, 28 (03): : 435 - 444
  • [47] Fluctuations of the non-Newtonian fluid flow in a Kenics static mixer: An experimental study
    Peryt-Stawiarska, Sylwia
    Jaworski, Zdzislaw
    POLISH JOURNAL OF CHEMICAL TECHNOLOGY, 2008, 10 (03) : 35 - 37
  • [48] Numerical investigation of turbulent flow and heat transfer characteristics in the improved Kenics static mixer
    Patil, Priyanka R.
    Dastane, Gaurav G.
    Pandit, Aniruddha B.
    HEAT TRANSFER, 2024, 53 (01) : 44 - 72
  • [49] CFD modelling of turbulent drop breakage in a kenics static mixer and comparison with experimental data
    Jaworski, Z.
    Pianko-Oprych, P.
    Marchisio, D. L.
    Nienow, A. W.
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2007, 85 (A5): : 753 - 759
  • [50] Kenics static mixer as turbulence promoter in cross-flow microfiltration of skim milk
    Krstic, DM
    Tekic, MN
    Caric, MD
    Milanovic, SD
    SEPARATION SCIENCE AND TECHNOLOGY, 2003, 38 (07) : 1549 - 1560