Design and characterization of Kenics static mixer crystallizers

被引:22
|
作者
Thomas, Kiran Mathew [1 ]
Nyande, Baggie W. [1 ]
Lakerveld, Richard [1 ]
机构
[1] Hong Kong Univ Sci & Technol, Dept Chem & Biol Engn, Clear Water Bay, Hong Kong, Peoples R China
来源
关键词
Crystallization; Static mixer; Continuous crystallization; CFD; Lysozyme; 3D printing; FLOW TUBULAR CRYSTALLIZATION; RESIDENCE TIME DISTRIBUTION; NATURAL COOLING MODE; PRESSURE-DRIVEN FLOW; PARTICLE MIGRATION; PROTEIN CRYSTALLIZATION; PROCESS INTENSIFICATION; BATCH CRYSTALLIZATION; SECONDARY NUCLEATION; POLYMORPH SELECTION;
D O I
10.1016/j.cherd.2022.01.025
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Tubular crystallizers are desirable for continuous operations because they can approach plug flow conditions, achieve higher throughputs, and can be easy to control. However, the possible limitations of tubular crystallizers may include settling of crystals, fouling and higher pressure drops at longer residence times. The performance of a tubular crystallizer with gaps between the Kenics type mixing elements is characterized and compared with a standard Kenics static mixer and a hollow tubular crystallizer for the crystallization of lysozyme from solution. The gapped Kenics static mixer crystallizer provides an attractive trade-off between the standard Kenics static mixer and the hollow tubular crystallizer in terms of mixing length, shear rate, residence time distribution, pressure drop and segregation or settling of crystals. Furthermore, the gapped Kenics static mixer crystallizer and the standard Kenics static mixer crystallizer exhibit a similar crystallization performance in terms of desupersaturation profile and mean crystal size at the outlet for different initial lysozyme concentrations and seed loadings. The advantages of the gapped Kenics static mixer crystallizer in terms of pressure drop and minimization of crystal settling allow for lower flow rates and longer residence times under plug flow conditions, which has important practical benefits for continuous crystallization. (c) 2022 Published by Elsevier Ltd on behalf of Institution of Chemical Engineers.
引用
收藏
页码:549 / 563
页数:15
相关论文
共 50 条
  • [21] Quantification of laminar mixing in the Kenics static mixer: An experimental study
    Jaffer, SA
    Wood, PE
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1998, 76 (03): : 516 - 521
  • [22] Effect of Geometry Design on Mixing Performance of Newtonian Fluids using Helical Overlapped Mixer Elements in Kenics Static Mixer
    Talhaoui, A.
    Draoui, B.
    Youcefi, A.
    JOURNAL OF APPLIED FLUID MECHANICS, 2021, 14 (06) : 1643 - 1656
  • [23] Reynolds number effects on laminar mixing in the Kenics static mixer
    Hobbs, DM
    Muzzio, FJ
    CHEMICAL ENGINEERING JOURNAL, 1998, 70 (02) : 93 - 104
  • [24] Effect of Aspect Ratio on the Mixing Performance in the Kenics Static Mixer
    Jiang, Xingren
    Yang, Ning
    Wang, Rijie
    PROCESSES, 2021, 9 (03)
  • [25] KENICS STATIC MIXER AND ITS POSSIBLE APPLICATIONS IN PROCESSING OPERATIONS
    BOR, TP
    FETTE SEIFEN ANSTRICHMITTEL VERBUNDEN MIT DER ZEITSCHRIFT DIE ERNAHRUNGSINDUSTRIE, 1972, 74 (08): : 449 - &
  • [26] The Kenics static mixer: a three-dimensional chaotic flow
    Hobbs, DM
    Muzzio, FJ
    CHEMICAL ENGINEERING JOURNAL, 1997, 67 (03): : 153 - 166
  • [27] EFFECT OF ELEMENTS CONNECTION TYPES ON MIXING PERFORMANCE OF KENICS STATIC MIXER
    Li, Zhijun
    Wang, Jiankang
    Zheng, Yiwen
    Wang, Chenyang
    MECHANIKA, 2024, 30 (05): : 466 - 471
  • [28] Analysis of the Calcium Alginate Gelation Process Using a Kenics Static Mixer
    Hozumi, Takuro
    Ohta, Seiichi
    Ito, Taichi
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2015, 54 (07) : 2099 - 2107
  • [29] Performance of Kenics static mixer over a wide range of Reynolds number
    Kumar, Vimal
    Shirke, Vaibhav
    Nigam, K. D. P.
    CHEMICAL ENGINEERING JOURNAL, 2008, 139 (02) : 284 - 295
  • [30] Optimization of a Kenics static mixer for non-creeping flow conditions
    Byrde, O
    Sawley, ML
    CHEMICAL ENGINEERING JOURNAL, 1999, 72 (02) : 163 - 169