Chromatographic alignment of LC-MS and LC-MS/MS datasets by genetic algorithm feature extraction

被引:36
|
作者
Palmblad, Magnus
Mills, Davinia J.
Bindschedler, Laurence V.
Cramer, Rainer
机构
[1] Univ Reading, BioCtr, Reading RG6 6AS, Berks, England
[2] Univ Reading, Dept Chem, Reading RG6 2AD, Berks, England
关键词
D O I
10.1016/j.jasms.2007.07.018
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Liquid chromatography-mass spectrometry (LC-MS) datasets can be compared or combined following chromatographic alignment. Here we describe a simple solution to the specific problem of aligning one LC-MS dataset and one LC-MS/MS dataset, acquired on separate instruments from an enzymatic digest of a protein mixture, using feature extraction and a genetic algorithm. First, the LC-MS dataset is searched within a few ppm of the calculated theoretical masses of peptides confidently identified by LC-MS/MS. A piecewise linear function is then fitted to these matched peptides using a genetic algorithm with a fitness function that is insensitive to incorrect matches but sufficiently flexible to adapt to the discrete shifts common when comparing LC datasets. We demonstrate the utility of this method by aligning ion trap LC-MS/MS data with accurate LC-MS data from an FTICR mass spectrometer and show how hybrid datasets can improve peptide and protein identification by combining the speed of the ion trap with the mass accuracy of the FTICR, similar to using a hybrid ion trap-FTICR instrument. We also show that the high resolving power of FTICR can improve precision and linear dynamic range in quantitative proteomics. The alignment software, msalign, is freely available as open source.
引用
收藏
页码:1835 / 1843
页数:9
相关论文
共 50 条
  • [31] Buffer Considerations for LC and LC-MS
    Subirats, Xavier
    Bosch, Elisabeth
    Roses, Marti
    [J]. LC GC NORTH AMERICA, 2009, 27 (11) : 1000 - 1004
  • [32] USING ION MOBILITY LC-MS AND LC-MS/MS TO RESOLVE AND IDENTIFY ISOBARIC GLUCURONIDE METABOLITES
    Kirk, Jayne
    Sanig, Rachel
    Mortishire-Smith, Russell
    Naughton, Sherri
    Alelyunas, Yun
    Wrona, Mark
    [J]. DRUG METABOLISM AND PHARMACOKINETICS, 2018, 33 (01) : S77 - S78
  • [33] In electrospray ionization source hydrogen/deuterium exchange LC-MS and LC-MS/MS for characterization of metabolites
    Lam, W
    Ramanathan, R
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2002, 13 (04) : 345 - 353
  • [34] Quantitation of melatonin and n-acetylserotonin in human plasma by nanoflow LC-MS/MS and electrospray LC-MS/MS
    Carter, Melissa D.
    Calcutt, M. Wade
    Malow, Beth A.
    Rose, Kristie L.
    Hachey, David L.
    [J]. JOURNAL OF MASS SPECTROMETRY, 2012, 47 (03): : 277 - 285
  • [35] Multiresidue analysis of pesticides by electrospray LC-MS and LC-MS-MS
    Volmer, DA
    Vollmer, DL
    Wilkes, JG
    [J]. LC GC-MAGAZINE OF SEPARATION SCIENCE, 1996, 14 (03): : 216 - &
  • [36] A Bioanalytical Method for Quantification of Thioredoxins in Bacillus anthracis by Digestion with Immobilized Pepsin and LC-MS/MS and On-line LC/LC-MS/MS
    Saleh, Aljona
    Edlund, Per-Olof
    Gustafsson, Tomas N.
    Sahlin, Margareta
    Sjoberg, Britt-Marie
    Granelli, Ingrid
    [J]. CHROMATOGRAPHIA, 2016, 79 (7-8) : 383 - 393
  • [37] Analysis of Fumagillin in Honey by LC-MS/MS
    Dmitrovic, Jasna
    Durden, David A.
    [J]. JOURNAL OF AOAC INTERNATIONAL, 2013, 96 (03) : 687 - 695
  • [38] Tacrolimus concentrations by ELISA and LC-MS/MS
    Aldea, Cornel
    Delean, Dan
    Bulata, Bogdan
    Duicu, Carmen
    Samasca, Gabriel
    Iancu, Mihaela
    Lupan, Iulia
    [J]. ROMANIAN BIOTECHNOLOGICAL LETTERS, 2019, 24 (05): : 845 - 850
  • [39] Salivary cortisol by LC-MS/MS.
    Taylor, RL
    Grebe, SK
    Singh, RJ
    [J]. CLINICAL CHEMISTRY, 2003, 49 (06) : A131 - A131
  • [40] LC-MS/MS Determination of Empagliflozin and Metformin
    Ayoub, Bassam M.
    Mowaka, Shereen
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2017, 55 (07) : 742 - 747