Quantitation of melatonin and n-acetylserotonin in human plasma by nanoflow LC-MS/MS and electrospray LC-MS/MS

被引:34
|
作者
Carter, Melissa D. [2 ]
Calcutt, M. Wade [2 ]
Malow, Beth A. [3 ]
Rose, Kristie L. [2 ]
Hachey, David L. [1 ,2 ]
机构
[1] Vanderbilt Univ, Dept Pharmacol, Nashville, TN 37232 USA
[2] Vanderbilt Univ, Dept Biochem, Nashville, TN 37235 USA
[3] Vanderbilt Univ, Dept Neurol, Nashville, TN 37232 USA
来源
JOURNAL OF MASS SPECTROMETRY | 2012年 / 47卷 / 03期
关键词
Melatonin; N-acetylserotonin; autism spectrum disorder; Nanoflow LC-MS; MS; AUTISM; DISORDERS; CHILDREN; FLUIDS;
D O I
10.1002/jms.2051
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Melatonin (MEL) and its chemical precursor N-acetylserotonin (NAS) are believed to be potential biomarkers for sleep-related disorders. Measurement of these compounds, however, has proven to be difficult due to their low circulating levels, especially that of NAS. Few methods offer the sensitivity, specificity and dynamic range needed to monitor MEL and its precursors and metabolites in small blood samples, such as those obtained from pediatric patients. In support of our ongoing study to determine the safety, tolerability and PK dosing strategies for MEL in treating insomnia in children with autism spectrum disorder, two highly sensitive LC-MS/MS assays were developed for the quantitation of MEL and precursor NAS at pg/mL levels in small volumes of human plasma. A validated electrospray ionization (ESI) method was used to quantitate high levels of MEL in PK studies, and a validated nanospray (nESI) method was developed for quantitation of MEL and NAS at endogenous levels. In both assays, plasma samples were processed by centrifugal membrane dialysis after addition of stable isotopic internal standards, and the components were separated by either conventional LC using a Waters SymmetryShield RP18 column (2.1 x 100 mm, 3.5 mu m) or on a polyimide-coated, fused-silica capillary self-packed with 17cm AquaC18 (3 mu m, 125 angstrom). Quantitation was done using the SRM transitions m/z 233-174 and m/z 219-160 for MEL and NAS, respectively. The analytical response ratio versus concentration curves were linear for MEL (nanoflow LC: 11.71165pg/mL, LC: 1165116500pg/mL) and for NAS (nanoflow LC: 11.01095pg/mL). Copyright (C) 2012 John Wiley & Sons, Ltd.
引用
收藏
页码:277 / 285
页数:9
相关论文
共 50 条
  • [1] Quantitative electrospray LC-MS and LC-MS/MS in biomedicine
    Carrascal, M
    Schneider, K
    Calaf, RE
    van Leeuwen, S
    Canosa, D
    Gelpí, E
    Abian, J
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 17 (6-7) : 1129 - 1138
  • [2] Quantitation of Cabozantinib in Human Plasma by LC-MS/MS
    Jones, Reyna
    Holleran, Julianne
    Parise, Robert A.
    Rudek, Michelle A.
    Chan, Jennifer
    Wen, Yujia
    Gobburu, Joga
    Lewis, Lionel D.
    Beumer, Jan H.
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2022, 60 (03) : 274 - 279
  • [3] LC-MS/MS quantitation of plasma progesterone in cattle
    Fernandes, R. M. T.
    Gomes, G. C.
    Porcari, A. M.
    Pimentel, J. R. V.
    Porciuncula, P. M.
    Martins-Junior, H. A.
    Miguez, P. H. P.
    da Costa, J. L.
    Amaral, P. H.
    Perecin, F.
    Meurer, E. C.
    Furtado, P. V.
    Simas, R. C.
    Eberlin, M. N.
    Ferreira, C. R.
    Madureira, E. H.
    [J]. THERIOGENOLOGY, 2011, 76 (07) : 1266 - 1274
  • [4] Quantification of nivolumab in human plasma by LC-MS/HRMS and LC-MS/MS, comparison with ELISA
    Millet, Aurelien
    Khoudour, Nihel
    Bros, Pauline
    Lebert, Dorothee
    Picard, Guillaume
    Machon, Christelle
    Goldwasser, Francois
    Blanchet, Benoit
    Guitton, Jerome
    [J]. TALANTA, 2021, 224
  • [5] Mucopolysaccharide quantitation in urine by LC-MS/MS
    Lacey, Jean M.
    Gavrilov, Dimitar K.
    Matern, Dietrich
    Oglesbee, Devin
    Raymond, Kimiyo
    Rinaldo, Piero
    Tortorelli, Silvia
    [J]. MOLECULAR GENETICS AND METABOLISM, 2019, 126 (02) : S89 - S90
  • [6] Multiresidue analysis of pesticides by electrospray LC-MS and LC-MS-MS
    Volmer, DA
    Vollmer, DL
    Wilkes, JG
    [J]. LC GC-MAGAZINE OF SEPARATION SCIENCE, 1996, 14 (03): : 216 - &
  • [7] Validation of an LC-MS/MS method for quantitation of fostemsavir in plasma
    Lolla, Siddhartha
    Gubbiyappa, Kumar Shiva
    Cheruku, Shankar
    Bhikshapathi, D. V. R. N.
    [J]. JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 2023, 120
  • [8] Quantitation of the anaesthetic xylazine in ovine plasma by LC-MS/MS
    Doran, Gregory S.
    Bradbury, Leah A.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 997 : 81 - 84
  • [9] Stable gradient nanoflow LC-MS
    Schneider, BB
    Guo, X
    Fell, LM
    Covey, TR
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2005, 16 (09) : 1545 - 1551
  • [10] LC-MS–MS Determination of Pregabalin in Human Plasma
    Vikas V. Vaidya
    Santosh M. Yetal
    Shikha M. N. Roy
    Noel A. Gomes
    Santosh S. Joshi
    [J]. Chromatographia, 2007, 66 : 925 - 928