Stable isotope ratio profiling of testosterone preparations

被引:42
|
作者
Cawley, Adam [1 ]
Collins, Michael [1 ]
Kazlauskas, Rymantas [1 ]
Handelsman, David J. [2 ]
Heywood, Robert [1 ]
Longworth, Mitchell [1 ]
Arenas-Queralt, Andrea [1 ]
机构
[1] Natl Measurement Inst, Australian Forens Drug Lab, Sydney, NSW 2073, Australia
[2] Univ Sydney, ANZAC Res Inst, Sydney, NSW 2006, Australia
关键词
testosterone (T); stable carbon isotope ratio (delta C-13) analysis; gas chromatography-combustion-isotope ratio mass spectrometry (GC-C-IRMS); stable hydrogen isotope ratio (delta H-2) analysis; gas chromatography-thermal conversion-isotope ratio mass spectrometry (GC-TC-IRMS); ENDOGENOUS URINARY STEROIDS; DOPING CONTROL PURPOSES; MASS-SPECTROMETRY; HYDROGEN ISOTOPES; C-13/C-12; RATIOS; CARBON; FRACTIONATION; CHROMATOGRAPHY; SPORT;
D O I
10.1002/dta.175
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Gas chromatography-combustion-isotope ratio mass spectrometry (GC-C-IRMS) is the preferred method of confirming the administration of exogenous testosterone by athletes. This relies on synthetic testosterone preparations being depleted in C-13 compared to natural testosterone. There is concern, however, about the existence of synthetic testosterone products that are unexpectedly C-13-enriched and which may allow athletes to circumvent the current GC-C-IRMS test. Further to the reported studies of legitimate pharmaceutical-grade testosterone products, a detailed analysis of seized materials from border-level seizures was required to obtain intelligence concerning trends in 'black market' testosterone manufacture and distribution. The sample set collected for this study between 2006 and 2009 inclusive provided a delta C-13 range (n=266) of -22.9 parts per thousand to -32.6 parts per thousand with mean and median values of -28.4 parts per thousand and -28.6 parts per thousand, respectively. Within this distribution there were 24 samples (9%) confirmed to have delta C-13 values in the range reported for endogenous urinary steroid metabolites (>= -25.8 parts per thousand). The benefit of delta C-13 profiling for testosterone preparations was demonstrated by the ability to identify specific seized products that can be target tested for future intelligence purposes. In addition, the potential of stable hydrogen isotope ratio (H-2/H-1; delta H-2) discrimination to complement delta C-13 analysis was investigated. Methodologies for the determination of delta H-2 values by gas chromatography-thermal conversion-isotope ratio mass spectrometry (GC-TC-IRMS) were developed to provide a delta H-2 range (n=173) of -177 parts per thousand to -268 parts per thousand with mean and median values of -231 parts per thousand and -234 parts per thousand, respectively. Copyright (C) 2010 John Wiley & Sons, Ltd.
引用
收藏
页码:557 / 567
页数:11
相关论文
共 50 条
  • [41] DETERMINATION OF VINEGAR AUTHENTICITY BY STABLE CARBON ISOTOPE RATIO ANALYSIS
    KANNO, K
    OYAMA, N
    FUJIMORI, M
    KAWAMURA, Y
    KATO, K
    NIPPON NOGEIKAGAKU KAISHI-JOURNAL OF THE JAPAN SOCIETY FOR BIOSCIENCE BIOTECHNOLOGY AND AGROCHEMISTRY, 1990, 64 (04): : 897 - 899
  • [42] Stable isotope ratio analysis of explosives - A new type of evidence
    Bagley, I
    Coleman, M
    Beadah, A
    Doyle, S
    Wakelin, D
    Stroud, M
    Ader, M
    Isaacs, M
    Poswa, A
    Brookes, S
    Belanger, C
    FORENSIC SCIENCE INTERNATIONAL, 2003, 136 : 140 - 140
  • [43] Stable isotope ratio analysis in sports anti-doping
    Cawley, Adam
    DRUG TESTING AND ANALYSIS, 2012, 4 (12) : 891 - 892
  • [44] USES OF STABLE ISOTOPE RATIO VARIATIONS IN BIOCHEMICAL AND BIOGEOCHEMICAL INVESTIGATIONS
    PARKER, PL
    ORGANIC MASS SPECTROMETRY, 1969, 2 (08): : 850 - &
  • [45] IMPROVED STABLE NITROGEN ISOTOPE RATIO MEASUREMENTS OF NATURAL GASES
    SOHNS, E
    GERLING, P
    FABER, E
    ANALYTICAL CHEMISTRY, 1994, 66 (17) : 2614 - 2620
  • [46] Stable carbon isotope ratio analysis of Australian orange juices
    Simpkins, WA
    Patel, G
    Harrison, M
    Goldberg, D
    FOOD CHEMISTRY, 2000, 70 (03) : 385 - 390
  • [47] Application of Stable Isotope Ratio Analysis for Origin Authentication of Pork
    Kim, Kyong Su
    Kim, Jae Sung
    Hwang, In Min
    Jeong, In Seon
    Khan, Naeem
    Lee, Sun Im
    Jeon, Dong Bok
    Song, Yang Hoon
    Kim, Kwan Suk
    KOREAN JOURNAL FOR FOOD SCIENCE OF ANIMAL RESOURCES, 2013, 33 (01) : 39 - 44
  • [48] STABLE ISOTOPE RATIO AS A TRACER OF MANGROVE CARBON IN MALAYSIAN ECOSYSTEMS
    RODELLI, MR
    GEARING, JN
    GEARING, PJ
    MARSHALL, N
    SASEKUMAR, A
    OECOLOGIA, 1984, 61 (03) : 326 - 333
  • [49] DETECTION OF ADULTERATED MAPLE PRODUCTS BY STABLE CARBON ISOTOPE RATIO
    CARRO, O
    HILLAIREMARCEL, C
    GAGNON, M
    JOURNAL OF THE ASSOCIATION OF OFFICIAL ANALYTICAL CHEMISTS, 1980, 63 (04): : 840 - 844
  • [50] Stable isotope ratio analysis for authentication of red yeast rice
    Perini, Matteo
    Carbone, Gianfranco
    Camin, Federica
    TALANTA, 2017, 174 : 228 - 233