Stable isotope ratio profiling of testosterone preparations

被引:42
|
作者
Cawley, Adam [1 ]
Collins, Michael [1 ]
Kazlauskas, Rymantas [1 ]
Handelsman, David J. [2 ]
Heywood, Robert [1 ]
Longworth, Mitchell [1 ]
Arenas-Queralt, Andrea [1 ]
机构
[1] Natl Measurement Inst, Australian Forens Drug Lab, Sydney, NSW 2073, Australia
[2] Univ Sydney, ANZAC Res Inst, Sydney, NSW 2006, Australia
关键词
testosterone (T); stable carbon isotope ratio (delta C-13) analysis; gas chromatography-combustion-isotope ratio mass spectrometry (GC-C-IRMS); stable hydrogen isotope ratio (delta H-2) analysis; gas chromatography-thermal conversion-isotope ratio mass spectrometry (GC-TC-IRMS); ENDOGENOUS URINARY STEROIDS; DOPING CONTROL PURPOSES; MASS-SPECTROMETRY; HYDROGEN ISOTOPES; C-13/C-12; RATIOS; CARBON; FRACTIONATION; CHROMATOGRAPHY; SPORT;
D O I
10.1002/dta.175
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Gas chromatography-combustion-isotope ratio mass spectrometry (GC-C-IRMS) is the preferred method of confirming the administration of exogenous testosterone by athletes. This relies on synthetic testosterone preparations being depleted in C-13 compared to natural testosterone. There is concern, however, about the existence of synthetic testosterone products that are unexpectedly C-13-enriched and which may allow athletes to circumvent the current GC-C-IRMS test. Further to the reported studies of legitimate pharmaceutical-grade testosterone products, a detailed analysis of seized materials from border-level seizures was required to obtain intelligence concerning trends in 'black market' testosterone manufacture and distribution. The sample set collected for this study between 2006 and 2009 inclusive provided a delta C-13 range (n=266) of -22.9 parts per thousand to -32.6 parts per thousand with mean and median values of -28.4 parts per thousand and -28.6 parts per thousand, respectively. Within this distribution there were 24 samples (9%) confirmed to have delta C-13 values in the range reported for endogenous urinary steroid metabolites (>= -25.8 parts per thousand). The benefit of delta C-13 profiling for testosterone preparations was demonstrated by the ability to identify specific seized products that can be target tested for future intelligence purposes. In addition, the potential of stable hydrogen isotope ratio (H-2/H-1; delta H-2) discrimination to complement delta C-13 analysis was investigated. Methodologies for the determination of delta H-2 values by gas chromatography-thermal conversion-isotope ratio mass spectrometry (GC-TC-IRMS) were developed to provide a delta H-2 range (n=173) of -177 parts per thousand to -268 parts per thousand with mean and median values of -231 parts per thousand and -234 parts per thousand, respectively. Copyright (C) 2010 John Wiley & Sons, Ltd.
引用
收藏
页码:557 / 567
页数:11
相关论文
共 50 条
  • [21] Stable carbon isotope ratio in xylotrophic fungi and their substrates
    Mukhin, V. A.
    Voronin, P. Yu
    Velivetskaya, T. A.
    Ignat'ev, A. V.
    RUSSIAN JOURNAL OF ECOLOGY, 2014, 45 (01) : 11 - 17
  • [22] Stable carbon isotope ratio in xylotrophic fungi and their substrates
    V. A. Mukhin
    P. Yu. Voronin
    T. A. Velivetskaya
    A. V. Ignat’ev
    Russian Journal of Ecology, 2014, 45 : 11 - 17
  • [23] Referencing strategies and techniques in stable isotope ratio analysis
    Werner, RA
    Brand, WA
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (07) : 501 - 519
  • [24] The stable carbon isotope ratio of biogenic emissions of isoprene and the potential use of stable isotope ratio measurements to study photochemical processing of isoprene in the atmosphere
    Rudolph, J
    Anderson, RS
    Czapiewski, KV
    Czuba, E
    Ernst, D
    Gillespie, T
    Huang, L
    Rigby, C
    Thompson, AE
    JOURNAL OF ATMOSPHERIC CHEMISTRY, 2003, 44 (01) : 39 - 55
  • [25] The Stable Carbon Isotope Ratio of Biogenic Emissions of Isoprene and the Potential Use of Stable Isotope Ratio Measurements to Study Photochemical Processing of Isoprene in the Atmosphere
    J. Rudolph
    R. S. Anderson
    K. V. Czapiewski
    E. Czuba
    D. Ernst
    T. Gillespie
    L. Huang
    C. Rigby
    A. E. Thompson
    Journal of Atmospheric Chemistry, 2003, 44 : 39 - 55
  • [26] Application of stable carbon isotope analysis to the detection of testosterone administration to cattle
    Hebestreit, M
    Flenker, U
    Buisson, C
    Andre, F
    Le Bizec, B
    Fry, H
    Lang, M
    Weigert, AP
    Heinrich, K
    Hird, S
    Schänzer, W
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2006, 54 (08) : 2850 - 2858
  • [27] The use of stable carbon isotope analysis to detect the abuse of testosterone in cattle
    Mason, PM
    Hall, SE
    Gilmour, I
    Houghton, E
    Pillinger, C
    Seymour, MA
    ANALYST, 1998, 123 (12) : 2405 - 2408
  • [28] Profiling of urinary formestane and confirmation by isotope ratio mass spectrometry
    Polet, Michael
    Van Renterghem, Pieter
    Van Gansbeke, Wim
    Van Eenoo, Peter
    STEROIDS, 2013, 78 (11) : 1103 - 1109
  • [29] Stable carbon isotope ratio for sugar, amino acid, and caffeine by liquid chromatography/isotope ratio mass spectrometry
    Suto, Nana
    Kawashim, Hiroto
    11TH APPLIED ISOTOPE GEOCHEMISTRY CONFERENCE AIG-11, 2015, 13 : 181 - 184
  • [30] Determination of Formaldehyde Stable Carbon Isotope Ratio in Squid by Gas Chromatography/Combustion / Isotope Ratio Mass Spectrometry
    Han L.
    Yu T.
    Liu D.
    Wang H.
    Jiang F.
    Journal of Chinese Institute of Food Science and Technology, 2022, 22 (02) : 337 - 344