Hemodynamic Effect of Flow Diverter and Coils in Treatment of Large and Giant Intracranial Aneurysms

被引:33
|
作者
Jing, Linkai [1 ]
Zhong, Jingru [2 ]
Liu, Jian [1 ]
Yang, Xinjian [1 ]
Paliwal, Nikhil [3 ,6 ]
Meng, Hui [3 ,4 ,5 ,6 ]
Wang, Shengzhang [7 ]
Zhang, Ying [1 ]
机构
[1] Capital Med Univ, Beijing Tiantan Hosp, Beijing Neurosurg Inst, Beijing, Peoples R China
[2] Capital Med Univ, Dept Biomed Engn, Beijing, Peoples R China
[3] Univ Buffalo, Dept Mech & Aerosp Engn, Buffalo, NY USA
[4] Univ Buffalo, Dept Neurosurg, Buffalo, NY USA
[5] Univ Buffalo, Dept Biomed Engn, Buffalo, NY USA
[6] Univ Buffalo, Toshiba Stroke & Vasc Res Ctr, Buffalo, NY USA
[7] Fudan Univ, Dept Engn Sci & Mech, Shanghai 200433, Peoples R China
基金
中国国家自然科学基金;
关键词
Aneurysm; Coil; Computational fluid dynamics; Flow diverter; Hemodynamics; PIPELINE EMBOLIZATION DEVICE; SINGLE-CENTER EXPERIENCE; ENDOVASCULAR TREATMENT; DIVERSION TREATMENT; RECONSTRUCTION; MULTICENTER; BIFURCATION; THROMBOSIS; DYNAMICS; TUBRIDGE;
D O I
10.1016/j.wneu.2016.01.079
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: This study aimed to investigate the hemodynamic changes induced by a flow diverter (FD) and coils in the treatment of internal carotid artery aneurysms, as well as to evaluate the effect of this treatment by using angiographic follow-up data. METHODS: Six large and giant aneurysms were treated by the Tubridge FD and loose packing coils between June 2013 and May 2015. Patient-specific models were constructed and analyzed using a computational fluid dynamics (CFD) method. The virtual FD deployment method was used to implant the Tubridge stent into a 3-dimensional digital subtraction angiographic image of the aneurysms, and the coils were simulated by a porous medium model. RESULTS: Tubridge FD alone can significantly reduce the intra-aneurysmal flow velocity (0.17 +/-0.05 m/s-0.11 +/- 0.06 m/s, P < 0.001) and wall shear stress (WSS, 1.39 +/- 0.29 Pa-0.77 +/- 0.34 Pa, P = 0.001) and increase the low wall shear area (LSA, 6.38% +/- 1.49% -34.60% +/- 28.90%, P = 0.047). Coils, as a supplementary measure, further reduced the velocity (0.11 +/-0.06 m/s-0.08 +/-0.05 m/s, P = 0.03) and WSS (0.77 +/- 0.34 Pa-0.47 +/-0.35 Pa, P = 0.04) and increased the LSA (34.60% +/- 28.90% -63.33% +/- 34.82%, P = 0.044). Aneurysm with sustained strong inflow after treatment (case 3, 25% reduction in velocity, 12% reduction in WSS, and 16% increment in LSA) showed partial patency, whereas others with a weaker inflow jet (mean 56% reduction in velocity, 74% reduction in WSS, and 1081% increment in LSA) showed complete occlusion at follow-up. CONCLUSIONS: On the basis of using the CFD method, adjunctive coiling with the Tubridge FD placement may significantly reduce intra-aneurysmal flow velocity and WSS, promoting thrombosis formation and occlusion of aneurysms.
引用
收藏
页码:199 / 207
页数:9
相关论文
共 50 条
  • [31] Delayed ipsilateral parenchymal hemorrhage following treatment of intracranial aneurysms with flow diverter
    Catherine Tomas
    Azzedine Benaissa
    Denis Herbreteau
    Krzysztof Kadziolka
    Laurent Pierot
    Neuroradiology, 2014, 56 : 155 - 161
  • [32] The Efficacy of Flow Diverter Stents in the Treatment of Wide-Necked Intracranial Aneurysms
    Ozdemir, Adnan
    Arslan, Serdar
    Duman, Enes
    Yildirim, Erkan
    Aytekin, Cuneyt
    Boyvat, Fatih
    IRANIAN JOURNAL OF RADIOLOGY, 2017, 14 (04)
  • [33] Flow Diverter Performance for the Treatment of Intracranial Aneurysms: An International Multicenter Comparative Study
    Vivanco-Suarez, Juan
    Basilio Flores, Juan E.
    Rodriguez-Calienes, Aaron
    Carlos Miranda, Juan
    Foa, Gustavo
    Altschul, David
    Aguilar-Melgar, Joel A.
    Dajles, Andres
    Galecio-Castillo, Milagros
    Zevallos, Cynthia B.
    Farooqui, Mudassir
    Puri, Ajit S.
    Pacheco-Fernandez Baca, Henry
    Ortega-Gutierrez, Santiago
    STROKE-VASCULAR AND INTERVENTIONAL NEUROLOGY, 2023, 3 (02):
  • [34] Analysis of the effect of platelet function and different doses of ticagrelor after flow diverter treatment of intracranial aneurysms
    Ge, Runze
    Lin, Jiancheng
    Feng, Xin
    Huang, Chi
    Huang, Jiwan
    Li, Can
    Wen, Zhuohua
    Xu, Anqi
    Huang, Mengshi
    Yuan, Hao
    Shi, Hongyu
    Ma, Gengwu
    Yi, Ruizhe
    Liang, Shuyin
    Bi, Yiming
    Su, Shixing
    Zhang, Xin
    Li, Xifeng
    Duan, Chuanzhi
    NEUROSURGICAL REVIEW, 2025, 48 (01)
  • [35] GIANT INTRACRANIAL ANEURYSMS - SELECTIVE ENDOVASCULAR THERAPY BY COILS
    CASASCO, A
    ARNAUD, O
    GOBIN, P
    AYMARD, A
    GEORGE, B
    COPHIGNON, J
    MERLAND, JJ
    NEUROCHIRURGIE, 1992, 38 (01) : 18 - 26
  • [36] Effect of bioactive coils on endovascular treatment outcomes for intracranial aneurysms
    Ding, Dale
    Starke, Robert M.
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2014, 343 (1-2) : 240 - 241
  • [37] Hemodynamic study on the therapeutic effects of varying diameter embolic coils in the treatment of intracranial aneurysms
    Ren, Xiaoyu
    Li, Haoran
    Xu, Kaihang
    Li, Zhongkai
    Gao, Bin
    Lu, Wangsheng
    Yang, Guangming
    Wang, Yunjie
    Yin, Yin
    Chen, Tao
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2024, 40 (03)
  • [38] Correlating Hemodynamic Changes and Occlusion Time after Flow Diverter Treatment of Bilateral Large Internal Carotid Artery Aneurysms
    A. C.-O. Tsang
    A. Y.-S. Tang
    W. C. Chung
    G. K.-K. Leung
    K. W. Chow
    Clinical Neuroradiology, 2016, 26 : 477 - 480
  • [39] Endovascular Treatment of Large and Giant Carotid Aneurysms with Flow-Diverter Stents Alone or in Combination with Coils: A Multicenter Experience and Long-Term Follow-up
    Peschillo, Simone
    Caporlingua, Alessandro
    Resta, Maria Chiara
    Peluso, Jo Peter Paul
    Burdi, Nicola
    Sourour, Nader
    Diana, Francesco
    Guidetti, Giulio
    Clarencon, Frederic
    Bloemsma, Gijs Coenraad
    Di Maria, Federico
    Donatelli, Massimo
    Resta, Maurizio
    OPERATIVE NEUROSURGERY, 2017, 13 (04) : 492 - 502
  • [40] Correlating Hemodynamic Changes and Occlusion Time after Flow Diverter Treatment of Bilateral Large Internal Carotid Artery Aneurysms
    Tsang, A. C. -O.
    Tang, A. Y. -S.
    Chung, W. C.
    Leung, G. K. -K.
    Chow, K. W.
    CLINICAL NEURORADIOLOGY, 2016, 26 (04) : 477 - 480