Hemodynamic Effect of Flow Diverter and Coils in Treatment of Large and Giant Intracranial Aneurysms

被引:33
|
作者
Jing, Linkai [1 ]
Zhong, Jingru [2 ]
Liu, Jian [1 ]
Yang, Xinjian [1 ]
Paliwal, Nikhil [3 ,6 ]
Meng, Hui [3 ,4 ,5 ,6 ]
Wang, Shengzhang [7 ]
Zhang, Ying [1 ]
机构
[1] Capital Med Univ, Beijing Tiantan Hosp, Beijing Neurosurg Inst, Beijing, Peoples R China
[2] Capital Med Univ, Dept Biomed Engn, Beijing, Peoples R China
[3] Univ Buffalo, Dept Mech & Aerosp Engn, Buffalo, NY USA
[4] Univ Buffalo, Dept Neurosurg, Buffalo, NY USA
[5] Univ Buffalo, Dept Biomed Engn, Buffalo, NY USA
[6] Univ Buffalo, Toshiba Stroke & Vasc Res Ctr, Buffalo, NY USA
[7] Fudan Univ, Dept Engn Sci & Mech, Shanghai 200433, Peoples R China
基金
中国国家自然科学基金;
关键词
Aneurysm; Coil; Computational fluid dynamics; Flow diverter; Hemodynamics; PIPELINE EMBOLIZATION DEVICE; SINGLE-CENTER EXPERIENCE; ENDOVASCULAR TREATMENT; DIVERSION TREATMENT; RECONSTRUCTION; MULTICENTER; BIFURCATION; THROMBOSIS; DYNAMICS; TUBRIDGE;
D O I
10.1016/j.wneu.2016.01.079
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: This study aimed to investigate the hemodynamic changes induced by a flow diverter (FD) and coils in the treatment of internal carotid artery aneurysms, as well as to evaluate the effect of this treatment by using angiographic follow-up data. METHODS: Six large and giant aneurysms were treated by the Tubridge FD and loose packing coils between June 2013 and May 2015. Patient-specific models were constructed and analyzed using a computational fluid dynamics (CFD) method. The virtual FD deployment method was used to implant the Tubridge stent into a 3-dimensional digital subtraction angiographic image of the aneurysms, and the coils were simulated by a porous medium model. RESULTS: Tubridge FD alone can significantly reduce the intra-aneurysmal flow velocity (0.17 +/-0.05 m/s-0.11 +/- 0.06 m/s, P < 0.001) and wall shear stress (WSS, 1.39 +/- 0.29 Pa-0.77 +/- 0.34 Pa, P = 0.001) and increase the low wall shear area (LSA, 6.38% +/- 1.49% -34.60% +/- 28.90%, P = 0.047). Coils, as a supplementary measure, further reduced the velocity (0.11 +/-0.06 m/s-0.08 +/-0.05 m/s, P = 0.03) and WSS (0.77 +/- 0.34 Pa-0.47 +/-0.35 Pa, P = 0.04) and increased the LSA (34.60% +/- 28.90% -63.33% +/- 34.82%, P = 0.044). Aneurysm with sustained strong inflow after treatment (case 3, 25% reduction in velocity, 12% reduction in WSS, and 16% increment in LSA) showed partial patency, whereas others with a weaker inflow jet (mean 56% reduction in velocity, 74% reduction in WSS, and 1081% increment in LSA) showed complete occlusion at follow-up. CONCLUSIONS: On the basis of using the CFD method, adjunctive coiling with the Tubridge FD placement may significantly reduce intra-aneurysmal flow velocity and WSS, promoting thrombosis formation and occlusion of aneurysms.
引用
收藏
页码:199 / 207
页数:9
相关论文
共 50 条
  • [21] Initial Experience with Surpass Evolve Flow Diverter in the Treatment of Intracranial Aneurysms
    V. Maus
    W. Weber
    A. Berlis
    C. Maurer
    S. Fischer
    Clinical Neuroradiology, 2021, 31 : 681 - 689
  • [22] Surpass Flow Diverter in the Treatment of Intracranial Aneurysms: A Prospective Multicenter Study
    Wakhloo, A. K.
    Lylyk, P.
    de Vries, J.
    Taschner, C.
    Lundquist, J.
    Biondi, A.
    Hartmann, M.
    Szikora, I.
    Pierot, L.
    Sakai, N.
    Imamura, H.
    Sourour, N.
    Rennie, I.
    Skalej, M.
    Beuing, O.
    Bonafe, A.
    Mery, F.
    Turjman, F.
    Brouwer, P.
    Boccardi, E.
    Valvassori, L.
    Derakhshani, S.
    Litzenberg, M. W.
    Gounis, M. J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (01) : 98 - 107
  • [23] Initial Experience with Surpass Evolve Flow Diverter in the Treatment of Intracranial Aneurysms
    Maus, V.
    Weber, W.
    Berlis, A.
    Maurer, C.
    Fischer, S.
    CLINICAL NEURORADIOLOGY, 2021, 31 (03) : 681 - 689
  • [24] Hemodynamic analysis for endovascular treatment in small unruptured intracranial aneurysms: a matched comparison study of flow diverter versus LVIS
    Liu Jian
    Li Wenqiang
    Zhang Yisen
    Wang Kun
    Yang Xinjian
    Zhang Ying
    中华神经外科杂志(英文), 2022, 08 (02) : 73 - 81
  • [25] Hemodynamic analysis for endovascular treatment in small unruptured intracranial aneurysms: a matched comparison study of flow diverter versus LVIS
    Liu J.
    Li W.
    Zhang Y.
    Wang K.
    Yang X.
    Zhang Y.
    Chinese Neurosurgical Journal, 7 (1)
  • [26] LARGE AND GIANT INTRACRANIAL ANEURYSMS
    LOVRENCIC, M
    NEURORADIOLOGY, 1984, 26 (02) : 167 - 167
  • [27] Use of the Tubridge flow diverter in the treatment of intracranial aneurysms: a single center experience
    Li, Li
    Gao, Bu-Lang
    Wu, Qiao-Wei
    Shao, Qiu-Ji
    Wang, Zi-Liang
    Zhang, Kun
    Li, Tian-Xiao
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [28] Flow diversion treatment for giant intracranial serpentine aneurysms
    Tong, Xin
    He, Zijun
    Han, Mingyang
    Feng, Xin
    Duan, Chuanzhi
    Liu, Aihua
    FRONTIERS IN AGING NEUROSCIENCE, 2022, 14
  • [29] SILK flow diverter for treatment of intracranial aneurysms: initial experience and cost analysis
    Shankar, Jai Jai Shiva
    Vandorpe, Robert
    Pickett, Gwynedd
    Maloney, William
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2013, 5 : III11 - III15
  • [30] Delayed ipsilateral parenchymal hemorrhage following treatment of intracranial aneurysms with flow diverter
    Tomas, Catherine
    Benaissa, Azzedine
    Herbreteau, Denis
    Kadziolka, Krzysztof
    Pierot, Laurent
    NEURORADIOLOGY, 2014, 56 (02) : 155 - 161