Upgrade of RIKEN 18 GHz electron cyclotron resonance ion source using an electrode at floating potential

被引:6
|
作者
Nakagawa, T
Biri, S
Kidera, M
Miyazawa, Y
Hemmi, M
Chiba, T
Inabe, N
Kase, M
Kageyama, T
Kamigaito, O
Goto, A
Yano, Y
机构
[1] RIKEN, Inst Phys & Chem Res, Wako, Saitama 35101, Japan
[2] ATOMKI, Nucl Res Inst, H-4026 Debrecen, Hungary
来源
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS | 1998年 / 37卷 / 5A期
关键词
electron cyclotron resonance ion source; biased electrode; microwave power; extraction voltage;
D O I
10.1143/JJAP.37.2699
中图分类号
O59 [应用物理学];
学科分类号
摘要
We have observed the enhancement of the Ar11+ beam intensity from the RIKEN 18 GHz electron cyclotron resonance ion source (ECRIS) when using the electrode at the floating potential. We have successfully obtained the beam intensity of 280 e mu A for Ar11+ at an extraction voltage of 15 kV.
引用
收藏
页码:2699 / 2700
页数:2
相关论文
共 50 条
  • [31] Construction and development of the JAERI 18 GHz electron cyclotron resonance ion source
    Yokota, W
    Saitoh, Y
    Ishii, Y
    Nara, T
    Arakawa, K
    Wu, Y
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (03): : 977 - 979
  • [32] Development of an 18 GHz superconducting electron cyclotron resonance ion source at RCNP
    Yorita, Tetsuhiko
    Hatanaka, Kichiji
    Fukuda, Mitsuhiro
    Kibayashi, Mitsuru
    Morinobu, Shunpei
    Okamura, Hiroyuki
    Tamii, Atsushi
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (02):
  • [33] Upgrade of the GTS Electron Cyclotron Resonance Ion Source at GANIL
    Toivanen, V.
    Barue, C.
    Feierstein, C.
    Jardin, P.
    Lemagnen, F.
    Maunoury, L.
    Noury, F.
    Rousseau, P.
    PROCEEDINGS OF THE 17TH INTERNATIONAL CONFERENCE ON ION SOURCES, 2018, 2011
  • [34] Control system for the new RIKEN 28-GHz superconducting electron cyclotron resonance ion source for SRILAC
    Uchiyama, A.
    Nagatomo, T.
    Higurashi, Y.
    Ohnishi, J.
    Komiyama, M.
    Kumagai, K.
    Fujimaki, M.
    Yamauchi, H.
    Tamura, M.
    Kaneko, K.
    Fukunishi, N.
    Nakagawa, T.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2020, 91 (02):
  • [35] Mechanism of the increase of highly charged ion intensity by use of an electrode in the first-stage chamber of the RIKEN 10 GHz electron cyclotron resonance ion source
    Nakagawa, Takahide
    Kageyama, Tadashi
    Kase, Masayuki
    Goto, Akira
    Yano, Yasushige
    Japanese Journal of Applied Physics, Part 2: Letters, 1992, 31 (8 A):
  • [37] Enhancement of Ar8+ ion beam intensity from RIKEN 18 GHz electron cyclotron resonance ion source by optimizing the magnetic field configuration
    Higurashi, Y
    Nakagawa, T
    Kidera, M
    Aihara, T
    Kase, M
    Yano, Y
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 2003, 42 (6A): : 3656 - 3657
  • [38] Implementation of an operator intervention system for remote control of the RIKEN 28 GHz superconducting electron cyclotron resonance ion source
    Uchiyama, A.
    Furukawa, K.
    Higurashi, Y.
    Nakagawa, T.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (02):
  • [39] Plasma potential profile in a 2.45 GHz electron cyclotron resonance multicharged ion source
    Kato, Y
    Ishii, S
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (02): : 1176 - 1178
  • [40] Effect of magnetic-field configuration on the beam intensity from electron cyclotron resonance ion source and RIKEN superconducting electron cyclotron resonance ion source
    Nakagawa, T.
    Higurashi, Y.
    Kidera, M.
    Aihara, T.
    Kase, M.
    Goto, A.
    Yano, Y.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (03):