We have observed the enhancement of the Ar11+ beam intensity from the RIKEN 18 GHz electron cyclotron resonance ion source (ECRIS) when using the electrode at the floating potential. We have successfully obtained the beam intensity of 280 e mu A for Ar11+ at an extraction voltage of 15 kV.
引用
收藏
页码:2699 / 2700
页数:2
相关论文
共 50 条
  • [21] ATLAS 10 GHz electron cyclotron resonance ion source upgrade project
    Moehs, DP
    Vondrasek, R
    Pardo, RC
    Xie, D
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (02): : 761 - 763
  • [22] Electron cyclotron resonance ion source developments in RIKEN (invited)
    Nakagawa, T
    Aihara, T
    Higurashi, Y
    Kidera, M
    Kase, M
    Yano, Y
    Arai, I
    Arai, H
    Imanaka, M
    Lee, SM
    Arzumanyan, G
    Shirkov, G
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (05): : 1394 - 1398
  • [23] Production of multicharged Os ion beams from organic metal compounds using a RIKEN 18GHz electron cyclotron resonance ion source
    Nakagawa, T
    Kidera, M
    Miyazawa, Y
    Hemmi, M
    Chiba, T
    Inabe, N
    Kase, M
    Kageyama, T
    Kamigaito, O
    Goto, A
    Yano, Y
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1997, 36 (12A): : 7375 - 7376
  • [24] Enhancement of Ar8+ current extracted from RIKEN 18 GHz electron cyclotron resonance ion source by moving the plasma electrode toward the resonance zone
    Higurashi, Y
    Nakagawa, T
    Kidera, M
    Aihara, T
    Kase, M
    Yano, Y
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 2001, 40 (08): : 5134 - 5135
  • [25] Determination of ion confinement time in RIKEN 18 GHz electron cyclotron resonance ion source (ECRIS) under pulsed mode operation
    Nakagawa, T
    Miyazawa, Y
    Hemmi, M
    Chiba, T
    Inabe, N
    Kase, M
    Kageyama, T
    Kamigaito, O
    Goto, A
    Yano, Y
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 1996, 35 (9A): : L1124 - L1126
  • [26] Production of intense beams of highly charged metallic ions from RIKEN 18 GHz electron cyclotron resonance ion source
    Nakagawa, T
    Arje, J
    Miyazawa, Y
    Hemmi, M
    Chiba, T
    Inabe, N
    Kase, M
    Kageyama, T
    Kamigaito, O
    Kidera, M
    Goto, A
    Yano, Y
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (02): : 637 - 639
  • [27] Effect of the plasma electrode position and shape on the beam intensity of the highly charged ions from RIKEN 18 GHz electron-cyclotron-resonance ion source
    Higurashi, Y
    Nakagawa, T
    Kidera, M
    Aihara, T
    Kobayashi, K
    Kase, M
    Goto, A
    Yano, Y
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (03):
  • [28] 18 GHz upgrading of the superconducting electron cyclotron resonance ion source SERSE
    Gammino, S
    Ciavola, G
    Celona, L
    Castro, M
    Chines, F
    Marletta, S
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (09): : 3577 - 3582
  • [29] Design for an 18 GHz Open Hexapole Electron Cyclotron Resonance Ion Source
    Vondrasek, R. C.
    McLain, J.
    Scott, R. H.
    20TH INTERNATIONAL CONFERENCE ON ION SOURCES, 2024, 2743
  • [30] 18 GHz upgrading of the superconducting electron cyclotron resonance ion source SERSE
    INFN-Laboratori Nazionali del Sud, 95123 Catania, Italy
    Rev. Sci. Instrum., 9 (3577-3582):