High Accuracy Acoustic Relative Humidity Measurement in Duct Flow with Air

被引:21
|
作者
van Schaik, Wilhelm
Grooten, Mart [1 ]
Wernaart, Twan [1 ]
van der Geld, Cees [1 ]
机构
[1] Eindhoven Univ Technol, Dept Mech Engn, NL-5600 MB Eindhoven, Netherlands
来源
SENSORS | 2010年 / 10卷 / 08期
关键词
acoustics; relative humidity; humid air flow; TEMPERATURE; SENSORS;
D O I
10.3390/s100807421
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An acoustic relative humidity sensor for air-steam mixtures in duct flow is designed and tested. Theory, construction, calibration, considerations on dynamic response and results are presented. The measurement device is capable of measuring line averaged values of gas velocity, temperature and relative humidity ( R H) instantaneously, by applying two ultrasonic transducers and an array of four temperature sensors. Measurement ranges are: gas velocity of 0-12 m/s with an error of +/- 0.13 m/s, temperature 0-100 degrees C with an error of +/- 0.07 degrees C and relative humidity 0-100% with accuracy better than 2 % RH above 50 degrees C. Main advantage over conventional humidity sensors is the high sensitivity at high RH at temperatures exceeding 50 degrees C, with accuracy increasing with increasing temperature. The sensors are non-intrusive and resist highly humid environments.
引用
收藏
页码:7421 / 7433
页数:13
相关论文
共 50 条
  • [31] Energy Efficiency, Air Flow Regime and Relative Humidity in Air- Conditioned Surgical Operating Theatres
    Khalil, Essam E.
    ASHRAE TRANSACTIONS 2012, VOL 118, PT 1, 2012, 118 : 436 - 441
  • [32] Modeling of acoustic lined duct with and without grazing air flow by an analytical method
    Laly, Zacharie
    Atalla, Noureddine
    Meslioui, Sid-Ali
    El Bikri, Khalid
    NOISE CONTROL ENGINEERING JOURNAL, 2018, 66 (04) : 340 - 352
  • [33] STUDY ON SILENCER ACOUSTIC EFFICIENCY IN GAS-AIR FLOW DUCT BENDS
    Chugunkov, Dmitry
    Seyfelmlyukova, Galina
    Zhuravlev, Evgeniy
    AKUSTIKA, 2019, 32 : 141 - 143
  • [34] THE ACOUSTIC OUTPUT PRODUCED BY A STEADY AIR-FLOW THROUGH A CORRUGATED DUCT
    PETRIE, AM
    HUNTLEY, ID
    JOURNAL OF SOUND AND VIBRATION, 1980, 70 (01) : 1 - 9
  • [35] Relative Humidity Measurement of Air in Low-Temperature Ranges Using Low-Frequency Acoustic Waves and Correlation Signal Processing Techniques
    Guo, Miao
    Li, Yue
    Gao, Jingmin
    SENSORS, 2022, 22 (16)
  • [36] Influence of contamination on measurement accuracy of the calorimetric air flow sensor
    Sun, Zhongsheng
    Shen, Yongxi
    Yuan, Changrong
    Li, Xiaoning
    MEASUREMENT, 2019, 145 : 108 - 117
  • [37] Analysis of measurement accuracy of air flow sensor influenced by moisture
    Xu, Chunlin
    Zhou, Quan
    Guo, Xing
    Zhan, Shannan
    Xiong, Bo
    Jiang, Hao
    Liu, Sheng
    2015 16TH INTERNATIONAL CONFERENCE ON ELECTRONIC PACKAGING TECHNOLOGY, 2015,
  • [38] Stomatal response characteristics of Tradescantia virginiana grown at high relative air humidity
    Nejad, AR
    van Meeteren, U
    PHYSIOLOGIA PLANTARUM, 2005, 125 (03) : 324 - 332
  • [39] Mixed flow relative humidity generator
    Kishan, Hari
    Singh, Bhikham
    MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA, 2008, 23 (01): : 21 - 24
  • [40] Incorporating relative humidity improves the accuracy of precipitation phase discrimination in High Mountain Asia
    Sun, Fan
    Chen, Yaning
    Li, Yupeng
    Li, Zhi
    Duan, Weili
    Zhang, Qifei
    Chuan, Wang
    ATMOSPHERIC RESEARCH, 2022, 271