High Accuracy Acoustic Relative Humidity Measurement in Duct Flow with Air

被引:21
|
作者
van Schaik, Wilhelm
Grooten, Mart [1 ]
Wernaart, Twan [1 ]
van der Geld, Cees [1 ]
机构
[1] Eindhoven Univ Technol, Dept Mech Engn, NL-5600 MB Eindhoven, Netherlands
来源
SENSORS | 2010年 / 10卷 / 08期
关键词
acoustics; relative humidity; humid air flow; TEMPERATURE; SENSORS;
D O I
10.3390/s100807421
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An acoustic relative humidity sensor for air-steam mixtures in duct flow is designed and tested. Theory, construction, calibration, considerations on dynamic response and results are presented. The measurement device is capable of measuring line averaged values of gas velocity, temperature and relative humidity ( R H) instantaneously, by applying two ultrasonic transducers and an array of four temperature sensors. Measurement ranges are: gas velocity of 0-12 m/s with an error of +/- 0.13 m/s, temperature 0-100 degrees C with an error of +/- 0.07 degrees C and relative humidity 0-100% with accuracy better than 2 % RH above 50 degrees C. Main advantage over conventional humidity sensors is the high sensitivity at high RH at temperatures exceeding 50 degrees C, with accuracy increasing with increasing temperature. The sensors are non-intrusive and resist highly humid environments.
引用
收藏
页码:7421 / 7433
页数:13
相关论文
共 50 条
  • [21] EVAPORATIVE HEAT-LOSS AT HIGH RELATIVE AIR HUMIDITY IN POULTRY
    NICHELMANN, M
    TZSCHENTKE, B
    BURMEISTER, A
    ARCHIV FUR GEFLUGELKUNDE, 1991, 55 (03): : 111 - 115
  • [22] STOMATAL BEHAVIOUR IN TRADESCANTIA VIRGINIANA GROWN AT HIGH RELATIVE AIR HUMIDITY
    Rezaei, Neiad A.
    van Meeteren, U.
    ACTA PHYSIOLOGIAE PLANTARUM, 2004, 26 (03) : 84 - 84
  • [23] Neural modeling of relative air humidity
    Bialobrzewski, I.
    COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2008, 60 (01) : 1 - 7
  • [24] Limitations of the Photoacoustic Technique for Aerosol Absorption Measurement at High Relative Humidity
    Langridge, Justin M.
    Richardson, Mathews S.
    Lack, Daniel A.
    Brock, Charles A.
    Murphy, Daniel M.
    AEROSOL SCIENCE AND TECHNOLOGY, 2013, 47 (11) : 1163 - 1173
  • [25] Microwave system for relative humidity measurement
    Carullo, A.
    Ferrero, A.
    Parvis, M.
    Conference Record - IEEE Instrumentation and Measurement Technology Conference, 1999, 1 : 124 - 129
  • [26] Experimental Measurement of the Friction Loss of Air Flow in a Flexible Duct Air Distribution System
    Gharehdaghi, Samad
    Moujaes, Samir
    2017 ASHRAE WINTER CONFERENCE PAPERS, 2017,
  • [27] A microwave system for relative humidity measurement
    Carullo, A
    Ferrero, A
    Parvis, M
    IMTC/99: PROCEEDINGS OF THE 16TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS. 1-3, 1999, : 124 - 129
  • [28] INSTRUMENT FOR RELATIVE-HUMIDITY MEASUREMENT
    IRGUM, K
    ANALYTICAL CHEMISTRY, 1983, 55 (07) : 1186 - 1187
  • [29] The optimum design of the relative humidity measurement
    Wang Shuhai
    Sha Zhanyou
    An Guochen
    7th International Conference on Measurement and Control of Granular Materials, Proceedings, 2006, : 199 - 202
  • [30] RELATIVE-HUMIDITY AND ITS MEASUREMENT
    DEYONG, J
    APPITA, 1982, 35 (06): : 483 - 490