Ionomer and protein size analysis by analytical ultracentrifugation and electrospray scanning mobility particle sizer

被引:8
|
作者
Wawra, Simon E. [1 ]
Thoma, Martin [1 ]
Walter, Johannes [1 ,2 ]
Lubbert, Christian [1 ,2 ]
Thajudeen, Thaseem [1 ,2 ,3 ]
Damm, Cornelia [1 ]
Peukert, Wolfgang [1 ,2 ]
机构
[1] Friedrich Alexander Univ Erlangen Nurnberg FAU, Inst Particle Technol LFG, Cauerstr 4, D-91058 Erlangen, Germany
[2] Friedrich Alexander Univ Erlangen Nurnberg FAU, Interdisciplinary Ctr Funct Particle Syst FPS, Haberstr 9a, D-91058 Erlangen, Germany
[3] Indian Inst Technol Goa, Sch Mech Sci, Ponda 403401, India
关键词
Scanning mobility particle sizer; Analytical ultracentrifugation; Multiwavelength detector; Combined analysis; SEDIMENTATION-VELOCITY EXPERIMENTS; PERFLUOROSULFONATED IONOMERS; MULTIWAVELENGTH DETECTOR; PERFLUORINATED IONOMER; WATER ELECTROLYZER; MEMBRANE; NAFION; MASS; PERFORMANCE; SCATTERING;
D O I
10.1007/s00249-018-1314-2
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
By combining analytical ultracentrifugation (AUC) in liquid phase and scanning mobility particle sizer (SMPS) in the gas phase, additional information on the particle size and morphology has been obtained for rigid particles. In this paper, we transfer this concept to soft particles, allowing us to analyze the size and molar mass of the short side chain perfluorosulfonic acid ionomer Aquivion(A (R)) in a dilute aqueous suspension. The determination of the primary size and exact molar mass of this class of polymers is challenging since they are optically transparent and due to the formation of different aggregate structures depending on the concentration and solvent properties. First, validation of AUC and SMPS measurements was carried out using the well-defined biopolymers bovine serum albumin (BSA) and lysozyme (LYZ) to confirm the reliability of the results of the two unique and independent classifying methods. Then, the ionomer Aquivion(A (R)) was studied using both techniques. From the mean molar mass of 185 +/- 14 kDa obtained by AUC, a mean hydrodynamic diameter of 7.6 +/- 0.5 nm was calculated. The particle size obtained from SMPS (7.1 nm) agrees very well with the results from AUC showing that the molecule was transferred into the gas phase without significantly changing its structure. In conclusion, the Aquivion(A (R)) is molecularly dispersed in the used aqueous buffer solution without any aggregate formation in the investigated concentration range (< 2 g l(-1)).
引用
收藏
页码:777 / 787
页数:11
相关论文
共 50 条
  • [41] A fast scanning mobility particle spectrometer for monitoring transient particle size distributions
    Shah, SD
    Cocker, DR
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 2005, 39 (06) : 519 - 526
  • [42] COMPARISON AND COMBINATION OF AEROSOL-SIZE DISTRIBUTIONS MEASURED WITH A LOW-PRESSURE IMPACTOR, DIFFERENTIAL MOBILITY PARTICLE SIZER, ELECTRICAL AEROSOL ANALYZER, AND AERODYNAMIC PARTICLE SIZER
    PETERS, TM
    CHEIN, HM
    LUNDGREN, DA
    KEADY, PB
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 1993, 19 (03) : 396 - 405
  • [43] Revisiting matrix-based inversion of scanning mobility particle sizer (SMPS) and humidified tandem differential mobility analyzer (HTDMA) data
    Petters, Markus D.
    [J]. ATMOSPHERIC MEASUREMENT TECHNIQUES, 2021, 14 (12) : 7909 - 7928
  • [44] Assessment of Scanning Mobility Particle Sizer (SMPS) for online monitoring of delivered dose in an in vitro aerosol exposure system
    Shankar, Sripriya Nannu
    Mital, Kiran
    Le, Eric
    Lewis, Gregory S.
    Eiguren-Fernandez, Arantzazu
    Sabo-Attwood, Tara
    Wu, Chang-Yu
    [J]. TOXICOLOGY IN VITRO, 2023, 92
  • [45] Determining the 2D particle size distribution of plasmonic particles by means of analytical ultracentrifugation
    Wawra, S.E.
    Pflug, L.
    Thajudeen, T.
    Peukert, W.
    [J]. Chemie-Ingenieur-Technik, 2018, 90 (09) : 1214 - 1214
  • [46] Comparison of the DiSCmini Aerosol Monitor to a Handheld Condensation Particle Counter and a Scanning Mobility Particle Sizer for Submicrometer Sodium Chloride and Metal Aerosols
    Mills, Jessica B.
    Park, Jae Hong
    Peters, Thomas M.
    [J]. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2013, 10 (05) : 250 - 258
  • [47] Absolute protein quantification based on calibrated particle counting using electrospray-differential mobility analysis
    Mi, Wei
    Zhang, Xinyi
    Wang, Bin
    Sun, Ruixue
    Ma, Shangying
    Hu, Zhishang
    Dai, Xinhua
    [J]. ANALYTICA CHIMICA ACTA, 2024, 1304
  • [48] On the analysis of protein self-association by sedimentation velocity analytical ultracentrifugation
    Schuck, P
    [J]. ANALYTICAL BIOCHEMISTRY, 2003, 320 (01) : 104 - 124
  • [49] Performance Comparison of Field Portable Instruments to the Scanning Mobility Particle Sizer Using Monodispersed and Polydispersed Sodium Chloride Aerosols
    Vo, Evanly
    Horvatin, Matthew
    Zhuang, Ziqing
    [J]. ANNALS OF WORK EXPOSURES AND HEALTH, 2018, 62 (06) : 711 - 720
  • [50] Aerosol effective density measurement using scanning mobility particle sizer and quartz crystal microbalance with the estimation of involved uncertainty
    Sarangi, Bighnaraj
    Aggarwal, Shankar G.
    Sinha, Deepak
    Gupta, Prabhat K.
    [J]. ATMOSPHERIC MEASUREMENT TECHNIQUES, 2016, 9 (03) : 859 - 875