Ionomer and protein size analysis by analytical ultracentrifugation and electrospray scanning mobility particle sizer

被引:8
|
作者
Wawra, Simon E. [1 ]
Thoma, Martin [1 ]
Walter, Johannes [1 ,2 ]
Lubbert, Christian [1 ,2 ]
Thajudeen, Thaseem [1 ,2 ,3 ]
Damm, Cornelia [1 ]
Peukert, Wolfgang [1 ,2 ]
机构
[1] Friedrich Alexander Univ Erlangen Nurnberg FAU, Inst Particle Technol LFG, Cauerstr 4, D-91058 Erlangen, Germany
[2] Friedrich Alexander Univ Erlangen Nurnberg FAU, Interdisciplinary Ctr Funct Particle Syst FPS, Haberstr 9a, D-91058 Erlangen, Germany
[3] Indian Inst Technol Goa, Sch Mech Sci, Ponda 403401, India
关键词
Scanning mobility particle sizer; Analytical ultracentrifugation; Multiwavelength detector; Combined analysis; SEDIMENTATION-VELOCITY EXPERIMENTS; PERFLUOROSULFONATED IONOMERS; MULTIWAVELENGTH DETECTOR; PERFLUORINATED IONOMER; WATER ELECTROLYZER; MEMBRANE; NAFION; MASS; PERFORMANCE; SCATTERING;
D O I
10.1007/s00249-018-1314-2
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
By combining analytical ultracentrifugation (AUC) in liquid phase and scanning mobility particle sizer (SMPS) in the gas phase, additional information on the particle size and morphology has been obtained for rigid particles. In this paper, we transfer this concept to soft particles, allowing us to analyze the size and molar mass of the short side chain perfluorosulfonic acid ionomer Aquivion(A (R)) in a dilute aqueous suspension. The determination of the primary size and exact molar mass of this class of polymers is challenging since they are optically transparent and due to the formation of different aggregate structures depending on the concentration and solvent properties. First, validation of AUC and SMPS measurements was carried out using the well-defined biopolymers bovine serum albumin (BSA) and lysozyme (LYZ) to confirm the reliability of the results of the two unique and independent classifying methods. Then, the ionomer Aquivion(A (R)) was studied using both techniques. From the mean molar mass of 185 +/- 14 kDa obtained by AUC, a mean hydrodynamic diameter of 7.6 +/- 0.5 nm was calculated. The particle size obtained from SMPS (7.1 nm) agrees very well with the results from AUC showing that the molecule was transferred into the gas phase without significantly changing its structure. In conclusion, the Aquivion(A (R)) is molecularly dispersed in the used aqueous buffer solution without any aggregate formation in the investigated concentration range (< 2 g l(-1)).
引用
收藏
页码:777 / 787
页数:11
相关论文
共 50 条
  • [31] DROPLET SIZE MEASUREMENTS OF VARIOUS NEBULIZERS USING DIFFERENTIAL ELECTRICAL MOBILITY PARTICLE SIZER
    ZARRIN, F
    KAUFMAN, SL
    SOCHA, JR
    [J]. JOURNAL OF AEROSOL SCIENCE, 1991, 22 : S343 - S346
  • [32] Simple self-diagnostic method to identify the abnormal functioning of a scanning mobility particle sizer
    Joe, Yun-Haeng
    Shim, Joonmok
    Shin, Weon Gyu
    Park, Hyun-Seol
    [J]. JOURNAL OF AEROSOL SCIENCE, 2017, 114 : 130 - 138
  • [33] Comparison of laser-induced incandescence method with scanning mobility particle sizer technique:: The influence of probe sampling and laser heating on soot particle size distribution
    Krüger, V
    Wahl, C
    Hadef, R
    Geigle, KP
    Stricker, W
    Aigner, M
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2005, 16 (07) : 1477 - 1486
  • [34] Nanoparticles in cigarette smoke; real-time undiluted measurements by a scanning mobility particle sizer
    Wouter D. van Dijk
    Simone Gopal
    Paul T. J. Scheepers
    [J]. Analytical and Bioanalytical Chemistry, 2011, 399 : 3573 - 3578
  • [35] Nanoparticles in cigarette smoke; real-time undiluted measurements by a scanning mobility particle sizer
    van Dijk, Wouter D.
    Gopal, Simone
    Scheepers, Paul T. J.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 399 (10) : 3573 - 3578
  • [36] Determination of Particle Size, Core and Shell Size Distributions of Core–Shell Particles by Analytical Ultracentrifugation
    Schmidt, Thomas
    Linders, Jürgen
    Mayer, Christian
    Cölfen, Helmut
    [J]. Particle and Particle Systems Characterization, 2021, 38 (10):
  • [38] Analysis of fractal particles from diesel exhaust using a scanning-mobility particle sizer and laser-induced incandescence
    Park, Jongil
    Yoon, Jaehyuk
    Song, Soonho
    Chun, Kwang Min
    [J]. JOURNAL OF AEROSOL SCIENCE, 2010, 41 (06) : 531 - 540
  • [39] Determination of Particle Size, Core and Shell Size Distributions of Core-Shell Particles by Analytical Ultracentrifugation
    Schmidt, Thomas
    Linders, Jurgen
    Mayer, Christian
    Coelfen, Helmut
    [J]. PARTICLE & PARTICLE SYSTEMS CHARACTERIZATION, 2021, 38 (10)
  • [40] COMPARISON AND COMBINATION OF AEROSOL-SIZE DISTRIBUTIONS MEASURED WITH A LOW-PRESSURE IMPACTOR, DIFFERENTIAL MOBILITY PARTICLE SIZER, ELECTRICAL AEROSOL ANALYZER, AND AERODYNAMIC PARTICLE SIZER
    PETERS, TM
    CHEIN, HM
    LUNDGREN, DA
    KEADY, PB
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 1993, 19 (03) : 396 - 405