The Role of Intraoperative Transesophageal Echocardiography in Robotic Mitral Valve Repair

被引:10
|
作者
Wang, Yao [2 ]
Gao, Chang-qing [1 ]
Wang, Jia-li [3 ]
Yang, Ming
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Dept Cardiovasc Surg, Div Cardiovasc Surg, Beijing 100853, Peoples R China
[2] Chinese Peoples Liberat Army Gen Hosp, Div Echocardiog, Beijing 100853, Peoples R China
[3] Chinese Peoples Liberat Army Gen Hosp, Cardiovasc Surg Inst, Div Cardiopulm Bypass, Beijing 100853, Peoples R China
关键词
intraoperative transesophageal echocardiography; mitral regurgitation; mitral valve repair; minimally invasive cardiac surgery; REGURGITANT DEFECTS; AMERICAN SOCIETY; SURGERY; SEVERITY; ACCURACY; PROLAPSE; RECOMMENDATIONS; IDENTIFICATION; GUIDELINES; EXPERIENCE;
D O I
10.1111/j.1540-8175.2010.01274.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Robotic mitral valve (MV) repair is a new surgical technique that uses small incisions. Previous studies have demonstrated the importance of intraoperative transesophageal echocardiography (TEE) for conventional MV surgery with the use of a median sternotomy incision. The aim of the present study was to delineate the utility of intraoperative TEE in robotic MV repair. Methods: Intraoperative TEE was performed in 22 consecutive patients undergoing robotic MV repair for severe degenerative mitral regurgitation (MR) over a period of 2 years. Before cardiopulmonary bypass (CPB), TEE was used to define the lesions of degenerative MR and the localization of the prolapsed leaflets, and to evaluate the severity of MR. During establishment of peripheral CPB, TEE was used to guide placement of the cannulae in the inferior vena cava (IVC), superior vena cava (SVC), and ascending aorta (AAO). After weaning from CPB, TEE was used to assess immediately the competency of the surgical repair. Results: Agreement between TEE and surgical findings was excellent: 92.3% (kappa, 0.873) for the lesions of degenerative MR, and 98.5% (kappa, 0.943) for the localization of the prolapsed leaflets. Under TEE guidance, all the cannulae (100%) in the SVC, IVC, and AAO were placed correctly. TEE demonstrated all the patients (100%) had successful robotic MV repairs. Conclusions: Intraoperative TEE is a valuable adjunct in the assessment of robotic MV repair. (Echocardiography 2011;28:85-91).
引用
收藏
页码:85 / 91
页数:7
相关论文
共 50 条
  • [31] Intraoperative Evaluation of Mitral Stenosis by Transesophageal Echocardiography
    Cherry, Anne D.
    Maxwell, Cory D.
    Nicoara, Alina
    ANESTHESIA AND ANALGESIA, 2016, 123 (01): : 14 - 20
  • [32] INTRAOPERATIVE TRANSESOPHAGEAL COLOR-CODED DOPPLER ECHOCARDIOGRAPHY FOR EVALUATION OF RESIDUAL REGURGITATION AFTER MITRAL-VALVE REPAIR
    REICHERT, SLA
    VISSER, CA
    MOULIJN, AC
    SUTTORP, MJ
    VANDERBRINK, RBA
    KOOLEN, JJ
    JAARSMA, W
    VERMEULEN, F
    DUNNING, AJ
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1990, 100 (05): : 756 - 761
  • [33] Role of 3D Transesophageal Echocardiography for Transcatheter Mitral Valve Repair-A Mini Review
    Hirasawa, Kensuke
    Izumo, Masaki
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [34] Three dimensional versus two dimensinal transesophageal echocardiography in mitral valve repair
    Orta, R. Garcia
    Escobar, E. Moreno
    Alarcon, M. Vidal
    Lopez, M. F. Ruiz
    Ramirez, J. M. Oyonarte
    Torrano, J. Lara
    Herrero, T. Moreno
    Almagro, J. Azpitarte
    EUROPEAN HEART JOURNAL, 2006, 27 : 899 - 899
  • [35] Intraoperative Transesophageal Echocardiographic Imaging of Double Valve Repair for Aortic and Mitral Stenosis
    Sung, Tae-Yun
    Kim, Ju-Deok
    Muhammad, Hasmizy Bin
    Kang, Woon-Seok
    Kim, Seong-Hyop
    Yun, Tae-Gyoon
    Kim, Jun-Seok
    Kim, Tae-Yop
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2012, 29 (02): : 187 - 191
  • [36] Three-Dimensional Transesophageal Echocardiography Shows Dehiscence of Mitral Valve Repair
    Iida, Ryoji
    Shanks, Miriam
    TEXAS HEART INSTITUTE JOURNAL, 2012, 39 (05) : 772 - 773
  • [37] Transesophageal Echocardiography and Mitral Valve Repair: Chasing a "Not-So-Moving" Target
    Saraf, Rabya
    Montealegre-Gallegos, Mario
    Mahmood, Feroze
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2016, 30 (02) : 573 - 573
  • [38] Abnormal Mitral Valve Apparatus in a Case of Hypertrophic Obstructive Cardiomyopathy: Intraoperative Transesophageal Echocardiography
    Aggarwal, Neelam
    Khanuja, Jasbir Singh
    Arora, Sameer Saurabh
    Maria, Rahul
    ANNALS OF CARDIAC ANAESTHESIA, 2018, 21 (03) : 315 - 318
  • [39] Transesophageal Echocardiography-Related Complications During Mitral Valve Repair in Dogs
    Kurogochi, Kentaro
    Takahashi, Arane
    Nii, Yasuyuki
    Suzuki, Tomoya
    Mizuno, Masashi
    Uechi, Masami
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2025, 39 (02)
  • [40] Intraoperative Three-Dimensional Transesophageal Echocardiography: Reconstruction of Mitral Valve Ring Abscess
    Crain, Matthew A.
    Fazi, Alyssa
    Hayanga, Heather K.
    Cook, Chris C.
    Ellison, Matthew B.
    Sloyer, Daniel A.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2022, 36 (08) : 2563 - 2567