The Role of Intraoperative Transesophageal Echocardiography in Robotic Mitral Valve Repair

被引:10
|
作者
Wang, Yao [2 ]
Gao, Chang-qing [1 ]
Wang, Jia-li [3 ]
Yang, Ming
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Dept Cardiovasc Surg, Div Cardiovasc Surg, Beijing 100853, Peoples R China
[2] Chinese Peoples Liberat Army Gen Hosp, Div Echocardiog, Beijing 100853, Peoples R China
[3] Chinese Peoples Liberat Army Gen Hosp, Cardiovasc Surg Inst, Div Cardiopulm Bypass, Beijing 100853, Peoples R China
关键词
intraoperative transesophageal echocardiography; mitral regurgitation; mitral valve repair; minimally invasive cardiac surgery; REGURGITANT DEFECTS; AMERICAN SOCIETY; SURGERY; SEVERITY; ACCURACY; PROLAPSE; RECOMMENDATIONS; IDENTIFICATION; GUIDELINES; EXPERIENCE;
D O I
10.1111/j.1540-8175.2010.01274.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Robotic mitral valve (MV) repair is a new surgical technique that uses small incisions. Previous studies have demonstrated the importance of intraoperative transesophageal echocardiography (TEE) for conventional MV surgery with the use of a median sternotomy incision. The aim of the present study was to delineate the utility of intraoperative TEE in robotic MV repair. Methods: Intraoperative TEE was performed in 22 consecutive patients undergoing robotic MV repair for severe degenerative mitral regurgitation (MR) over a period of 2 years. Before cardiopulmonary bypass (CPB), TEE was used to define the lesions of degenerative MR and the localization of the prolapsed leaflets, and to evaluate the severity of MR. During establishment of peripheral CPB, TEE was used to guide placement of the cannulae in the inferior vena cava (IVC), superior vena cava (SVC), and ascending aorta (AAO). After weaning from CPB, TEE was used to assess immediately the competency of the surgical repair. Results: Agreement between TEE and surgical findings was excellent: 92.3% (kappa, 0.873) for the lesions of degenerative MR, and 98.5% (kappa, 0.943) for the localization of the prolapsed leaflets. Under TEE guidance, all the cannulae (100%) in the SVC, IVC, and AAO were placed correctly. TEE demonstrated all the patients (100%) had successful robotic MV repairs. Conclusions: Intraoperative TEE is a valuable adjunct in the assessment of robotic MV repair. (Echocardiography 2011;28:85-91).
引用
收藏
页码:85 / 91
页数:7
相关论文
共 50 条
  • [21] THE ROLE OF INTRAOPERATIVE TRANSESOPHAGEAL ECHOCARDIOGRAPHY IN THE DIAGNOSIS AND CORRECTION OF A MALFUNCTIONING ST JUDES MITRAL-VALVE
    CARR, G
    NEUSTEIN, SM
    GALLA, J
    SCHOR, J
    REICH, DL
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1995, 9 (03) : 312 - 316
  • [22] INTRAOPERATIVE TRANSESOPHAGEAL ECHOCARDIOGRAPHY AFTER MITRAL REPAIR - SPECIFIC CONDITIONS AND PITFALLS
    MIHAILEANU, S
    ELASMAR, B
    ACAR, C
    LAMBERTI, A
    DIEBOLD, B
    PERIER, P
    DREYFUS, G
    BENSASSON, D
    DANG, Y
    ILIESU, D
    CARPENTIER, A
    EUROPEAN HEART JOURNAL, 1991, 12 : 26 - 29
  • [23] Quantitative Modeling of the Mitral Valve by Three-Dimensional Transesophageal Echocardiography in Patients Undergoing Mitral Valve Repair: Correlation with Intraoperative Surgical Technique
    Calleja, Anna
    Poulin, Frederic
    Woo, Anna
    Meineri, Massimiliano
    Jedrzkiewicz, Sean
    Vannan, Mani A.
    Rakowski, Harry
    David, Tirone
    Tsang, Wendy
    Thavendiranathan, Paaladinesh
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2015, 28 (09) : 1083 - 1092
  • [24] INTRAOPERATIVE TRANSESOPHAGEAL ECHOCARDIOGRAPHY FOR THE EVALUATION OF MITRAL, AORTIC AND TRICUSPID-VALVE REPAIR - A TOOL TO OPTIMIZE SURGICAL OUTCOME
    DESIMONE, R
    LANGE, R
    SAGGAU, W
    GAMS, E
    TANZEEM, A
    HAGL, S
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1992, 6 (12) : 665 - 673
  • [25] INTRAOPERATIVE EVALUATION OF MITRAL-VALVE REGURGITATION AND REPAIR BY TRANSESOPHAGEAL ECHOCARDIOGRAPHY - INCIDENCE AND SIGNIFICANCE OF SYSTOLIC ANTERIOR MOTION
    FREEMAN, WK
    SCHAFF, HV
    KHANDHERIA, BK
    OH, JK
    ORSZULAK, TA
    ABEL, MD
    SEWARD, JB
    TAJIK, AJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (03) : 599 - 609
  • [26] Transesophageal echocardiography of the edge-to-edge technique of mitral valve repair
    Bader, Stephen O.
    Lattouf, Omar M.
    Sniecinski, Roman M.
    ANESTHESIA AND ANALGESIA, 2007, 105 (05): : 1231 - 1232
  • [27] Three-dimensional transesophageal echocardiography in mitral valve repair and replacement
    Dzhanketova, V. S.
    Golukhova, E. Z.
    Mashina, T. V.
    Shamsiev, G. A.
    Mrikaev, D. V.
    EUROPEAN HEART JOURNAL, 2017, 38 : 412 - 413
  • [28] Transesophageal echocardiography for cardiac herniation occurring during robotic-assisted mitral valve repair: a case report
    Kazuto Miyata
    Sayaka Shigematsu
    Naoki Miyayama
    JA Clinical Reports, 9
  • [29] Transesophageal echocardiography for cardiac herniation occurring during robotic-assisted mitral valve repair: a case report
    Miyata, Kazuto
    Shigematsu, Sayaka
    Miyayama, Naoki
    JA CLINICAL REPORTS, 2023, 9 (01)
  • [30] Iatrogenic Mitral Valve Injury During Aortic Valve Replacement: Importance of Intraoperative Transesophageal Echocardiography
    Steiman, Jennifer
    Chaney, Mark A.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2011, 25 (03) : 586 - 586