A JFET-CMOS fast preamplifier for segmented germanium detectors

被引:15
|
作者
Pullia, A. [1 ]
Zocca, F. [1 ]
Riboldi, S. [1 ]
机构
[1] Univ Milan, Ist Nazl Fis Nucl, Dept Phys, I-20133 Milan, Italy
关键词
CMOS preamplifier; charge-sensitive preamplifier; gamma ray spectroscopy;
D O I
10.1109/TNS.2007.914022
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A JFET-CMOS fast charge-sensitive preamplifier for germanium detectors, able to operate at cryogenic temperatures, has been designed, realized, and characterized. The monolithic part of the circuit is realized in a mature 5 V 0.8 mu m Si CMOS technology, which yields better performances than scaled technologies in this case. The input transistor is an external Si JFET, which can be easily replaced if necessary. The charge-to-voltage gain and the fall-time are as well set through an external RC,network. The circuit works in the wide temperature range of -196 to 55 degrees C and is able to drive a terminated coaxial cable with an exceptionally fast and clean transition. Namely, with a detector capacitance of 16 pF and a negative power supply of -3 V it is able to provide a -2.4 V pulse onto a 100 Omega load in less than 13 ns with no ringing. The static power consumption is 8 mW excluding the JFET. The area occupancy of the integrated circuit is as little as 366 x 275 mu m(2). The noise performance with a 16 pF detector capacitance is 110 r.m.s. electrons both at room temperature and at -196 degrees C, at a quasi-Gaussian shaping time of 10 mu s. The obtained performance is adequate for gamma-ray spectroscopy and pulse-shape analysis with bulky HPGe segmented detectors.
引用
收藏
页码:591 / 594
页数:4
相关论文
共 50 条
  • [31] NOVEL P-JFET EMBEDDED IN SILICON RADIATION DETECTORS THAT AVOIDS PREAMPLIFIER FEEDBACK RESISTOR
    SAMPIETRO, M
    FASOLI, L
    REHAK, P
    STRUDER, L
    IEEE ELECTRON DEVICE LETTERS, 1995, 16 (05) : 208 - 210
  • [32] Proof-of-principle for fast neutron detection with advanced tracking arrays of highly segmented germanium detectors
    Jenkins, D. G.
    Glover, R.
    Herzberg, R. D.
    Boston, A. J.
    Gray-Jones, C.
    Nordlund, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 602 (02): : 457 - 460
  • [33] A fast low noise charge preamplifier for position sensitive detectors
    Beltrán, D
    Perlas, JA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (08): : 3075 - 3079
  • [34] Optimization of a Time-over-Threshold Preamplifier for High Purity Germanium Detectors
    Pullia, A.
    Zocca, F.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 1354 - +
  • [35] An automatic energy-calibration method for segmented germanium detectors
    Hu, Z
    Glasmacher, T
    Mueller, WF
    Wiedenhöver, I
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 482 (03): : 715 - 719
  • [36] Photon identification with segmented germanium detectors in low radiation environments
    Abt, I.
    Caldwell, A.
    Kroeninger, K.
    Liu, J.
    Liu, X.
    Majorovits, B.
    Stelzer, F.
    TOPICAL WORSHOP ON LOW RADIOACTIVITY TECHNIQUES, 2007, 897 : 9 - +
  • [37] Position sensitivity of the proposed segmented germanium detectors for the DESPEC project
    Khaplanov, A.
    Tashenov, S.
    Cederwall, B.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 604 (1-2): : 56 - 59
  • [38] Bulk and surface effects in segmented high purity germanium detectors
    Abt, I.
    Caldwell, A.
    Doenmez, B.
    Irlbeck, S.
    Majorovits, B.
    Volynets, O.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 718 : 533 - 534
  • [39] CHARGE SENSITIVE PREAMPLIFIER AND PULSE SHAPER USING CMOS PROCESS FOR GERMANIUM SPECTROSCOPY
    KROEGER, RA
    JOHNSON, WN
    KINZER, RL
    KURFESS, JD
    INDERHEES, S
    ALLEN, MD
    ALLEY, GT
    BRITTON, CL
    CLONTS, LC
    ERICSON, MN
    SIMPSON, ML
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) : 921 - 924
  • [40] Low-noise CMOS preamplifier-shaper for silicon drift detectors
    Gramegna, G
    OConnor, P
    Rehak, P
    Hart, S
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 346 - 350