Postimplant dosimetry using a Monte Carlo dose calculation engine:: A new clinical standard

被引:61
|
作者
Carrier, Jean-Francois
D'Amours, Michel
Verhaegen, Frank
Reniers, Brigitte
Martin, Andre-Guy
Vigneault, Eric
Beaulieu, Luc
机构
[1] CHUM, Hop Notre Dame de Bon Secours, Dept Radiooncol, Montreal, PQ H2L 4M1, Canada
[2] CHUM, Hop Notre Dame de Bon Secours, Ctr Rech, Montreal, PQ H2L 4M1, Canada
[3] Univ Laval, Dept Radiooncol, Hotel Dieu, Laval, PQ, Canada
[4] Univ Laval, Ctr Rech & Cancerol, Hotel Dieu, Laval, PQ, Canada
[5] McGill Univ, Med Phys Unit, Montreal, PQ, Canada
关键词
prostate cancer; low-dose-rate brachytherapy; permanent seed implants; iodine-125; postimplant dosimetry; Monte Carlo;
D O I
10.1016/j.ijrobp.2007.02.036
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To use the Monte Carlo (MC) method as a dose calculation engine for postimplant dosimetry. To compare the results with clinically approved data for a sample of 28 patients. Two effects not taken into account by the clinical calculation, interseed attenuation and tissue composition, are being specifically investigated. Methods and Materials: An automated MC program was developed. The dose distributions were calculated for the target volume and organs at risk (OAR) for 28 patients. Additional MC techniques were developed to focus specifically on the interseed attenuation and tissue effects. Results: For the clinical target volume (CTV) D-90 parameter, the mean difference between the clinical technique and the complete MC method is 10.7 Gy, with cases reaching up to 17 Gy. For all cases, the clinical technique overestimates the deposited dose in the CTV. This overestimation is mainly from a combination of two effects: the interseed attenuation (average, 6.8 Gy) and tissue composition (average, 4.1 Gy). The deposited dose in the OARs is also overestimated in the clinical calculation. Conclusions: The clinical technique systematically overestimates the deposited dose in the prostate and in the OARs. To reduce this systematic inaccuracy, the MC method should be considered in establishing a new standard for clinical postimplant dosimetry and dose-outcome studies in a near future. (C) 2007 Elsevier Inc.
引用
收藏
页码:1190 / 1198
页数:9
相关论文
共 50 条
  • [41] Monte Carlo Finite-Size Pencil Beam Dose Calculation Engine for Accurate Radiotherapy
    Zheng, H.
    Wang, H.
    Cao, R.
    Song, J.
    He, T.
    Wu, Y.
    MEDICAL PHYSICS, 2017, 44 (06) : 2924 - 2924
  • [42] A GPU OpenCL based cross-platform Monte Carlo dose calculation engine (goMC)
    Tian, Zhen
    Shi, Feng
    Folkerts, Michael
    Qin, Nan
    Jiang, Steve B.
    Jia, Xun
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (19): : 7419 - 7435
  • [43] Evaluation of the first commercial Monte Carlo dose calculation engine for electron beam treatment planning
    Cygler, JE
    Daskalov, GM
    Chan, GH
    Ding, GX
    MEDICAL PHYSICS, 2004, 31 (01) : 142 - 153
  • [44] Modelling of electron contamination in clinical photon beams for Monte Carlo dose calculation
    Yang, J
    Li, JS
    Qin, L
    Xiong, W
    Ma, CM
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (12): : 2657 - 2673
  • [45] Clinical implementation of full Monte Carlo dose calculation in proton beam therapy
    Paganetti, Harald
    Jiang, Hongyu
    Parodi, Katia
    Slopsema, Roelf
    Engelsman, Martijn
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (17): : 4825 - 4853
  • [46] A 4D Monte Carlo Dose Calculation Method for Clinical Applications
    Zhong, H.
    Weiss, E.
    Rosu, M.
    Keall, P.
    Williamson, J.
    Siebers, J.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [47] A clinical study of lung cancer dose calculation accuracy with Monte Carlo simulation
    Zhao, Yanqun
    Qi, Guohai
    Yin, Gang
    Wang, Xianliang
    Wang, Pei
    Li, Jian
    Xiao, Mingyong
    Li, Jie
    Kang, Shengwei
    Liao, Xiongfei
    RADIATION ONCOLOGY, 2014, 9
  • [48] Evaluation of the Monte Carlo Dose Calculation Engine of Eclipse Treatment Planning System for Electron Beams
    Kamta, G. Lagmago
    Reniers, B.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [49] VALIDATION OF MONTE CARLO DOSE CALCULATION FOR PAEDIATRIC CT EXAMINATIONS USING TUBE CURRENT MODULATION BASED ON IN-PHANTOM DOSIMETRY
    Fujii, K.
    Nomura, K.
    Muramatsu, Y.
    Obara, S.
    Goto, T.
    Akahane, K.
    Ota, H.
    Tsukagoshi, S.
    Kusumoto, M.
    RADIATION PROTECTION DOSIMETRY, 2018, 182 (04) : 508 - 517
  • [50] A clinical study of lung cancer dose calculation accuracy with Monte Carlo simulation
    Yanqun Zhao
    Guohai Qi
    Gang Yin
    Xianliang Wang
    Pei Wang
    Jian Li
    Mingyong Xiao
    Jie Li
    Shengwei Kang
    Xiongfei Liao
    Radiation Oncology, 9