A clinical study of lung cancer dose calculation accuracy with Monte Carlo simulation

被引:26
|
作者
Zhao, Yanqun [1 ]
Qi, Guohai [1 ]
Yin, Gang [1 ]
Wang, Xianliang [1 ]
Wang, Pei [1 ]
Li, Jian [1 ]
Xiao, Mingyong [1 ]
Li, Jie [1 ]
Kang, Shengwei [1 ]
Liao, Xiongfei [1 ]
机构
[1] Sichuan Prov Canc Hosp, Dept Radiat Oncol, Chengdu 610041, Sichuan, Peoples R China
来源
RADIATION ONCOLOGY | 2014年 / 9卷
关键词
3-Dimensional conformal radiation therapy; Collapsed cone convolution; Pencil beam convolution; Lung cancer; Monte Carlo; Intensity-modulated radiation therapy; PENCIL-BEAM; DOSIMETRIC VERIFICATION; CALCULATION ALGORITHMS; RADIATION-THERAPY; COLLAPSED CONE; PHOTON BEAMS; IMRT; RADIOTHERAPY; ENERGY; INTERFACES;
D O I
10.1186/s13014-014-0287-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: The accuracy of dose calculation is crucial to the quality of treatment planning and, consequently, to the dose delivered to patients undergoing radiation therapy. Current general calculation algorithms such as Pencil Beam Convolution (PBC) and Collapsed Cone Convolution (CCC) have shortcomings in regard to severe inhomogeneities, particularly in those regions where charged particle equilibrium does not hold. The aim of this study was to evaluate the accuracy of the PBC and CCC algorithms in lung cancer radiotherapy using Monte Carlo (MC) technology. Methods and materials: Four treatment plans were designed using Oncentra Masterplan TPS for each patient. Two intensity-modulated radiation therapy (IMRT) plans were developed using the PBC and CCC algorithms, and two three-dimensional conformal therapy (3DCRT) plans were developed using the PBC and CCC algorithms. The DICOM-RT files of the treatment plans were exported to the Monte Carlo system to recalculate. The dose distributions of GTV, PTV and ipsilateral lung calculated by the TPS and MC were compared. Result: For 3DCRT and IMRT plans, the mean dose differences for GTV between the CCC and MC increased with decreasing of the GTV volume. For IMRT, the mean dose differences were found to be higher than that of 3DCRT. The CCC algorithm overestimated the GTV mean dose by approximately 3% for IMRT. For 3DCRT plans, when the volume of the GTV was greater than 100 cm(3), the mean doses calculated by CCC and MC almost have no difference. PBC shows large deviations from the MC algorithm. For the dose to the ipsilateral lung, the CCC algorithm overestimated the dose to the entire lung, and the PBC algorithm overestimated V-20 but underestimated V-5; the difference in V-10 was not statistically significant. Conclusions: PBC substantially overestimates the dose to the tumour, but the CCC is similar to the MC simulation. It is recommended that the treatment plans for lung cancer be developed using an advanced dose calculation algorithm other than PBC. MC can accurately calculate the dose distribution in lung cancer and can provide a notably effective tool for benchmarking the performance of other dose calculation algorithms within patients.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] A clinical study of lung cancer dose calculation accuracy with Monte Carlo simulation
    Yanqun Zhao
    Guohai Qi
    Gang Yin
    Xianliang Wang
    Pei Wang
    Jian Li
    Mingyong Xiao
    Jie Li
    Shengwei Kang
    Xiongfei Liao
    [J]. Radiation Oncology, 9
  • [2] Experimental and Monte Carlo Investigation of Dose Calculation Accuracy for Lung SBRT Planning
    Rosenfield, J.
    Manohar, N.
    Yang, X.
    Dong, X.
    Elder, E.
    Higgins, K.
    Dhabaan, A.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 2965 - 2965
  • [3] FRoG dose computation meets Monte Carlo accuracy for proton therapy dose calculation in lung
    Magro, Giuseppe
    Mein, Stewart
    Kopp, Benedikt
    Mastella, Edoardo
    Pella, Andrea
    Ciocca, Mario
    Mairani, Andrea
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 86 : 66 - 74
  • [4] Clinical verification of treatment planning dose calculation in lung SBRT with GATE Monte Carlo simulation code
    Boiset, Gisell Ruiz
    Batista, Delano V. S.
    Cardoso, Simone Coutinho
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 87 : 1 - 10
  • [5] Accuracy of the Monte Carlo Dose Calculation Algorithm for Cyberknife Treatment of Small Lung Lesions
    Hol, M.
    Marijnissen, J. P. A.
    van der Baan, P.
    Heijmen, B. J. M.
    [J]. MEDICAL PHYSICS, 2008, 35 (06) : 2953 - +
  • [6] Accuracy of Patient Dose Calculation in Proton Therapy of Lung Cancer: A Comparison of Monte Carlo and Pencil Beam Computations
    Mirkovic, D.
    Tit, U.
    Mohan, R.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [7] Experimental Validation of Clinical as Well as Monte Carlo Dose Calculation for Proton Therapy of Lung Cancer Patients
    Grassberger, C.
    Daartz, J.
    Dowdell, S.
    Verburg, J.
    Sharp, G.
    Paganetti, H.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [8] Dose Calculation of a Breast Cancer Brachytherapy Treatment Using Monte Carlo Simulation
    Graf, M.
    Scanderbeg, D.
    Cervino, L.
    Yashar, C.
    Jiang, S.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [9] Comparative Study of SBRT Lung Dose Calculation Using Eclipse and Monte Carlo
    Zhan, L.
    Schaly, B.
    Jiang, R.
    Osei, E. K.
    [J]. MEDICAL PHYSICS, 2012, 39 (07) : 4621 - 4621
  • [10] Clinical implementation of proton Monte Carlo dose calculation
    Paganetti, H
    Jiang, H
    Kollipara, S
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 2028 - 2028