A clinical study of lung cancer dose calculation accuracy with Monte Carlo simulation

被引:26
|
作者
Zhao, Yanqun [1 ]
Qi, Guohai [1 ]
Yin, Gang [1 ]
Wang, Xianliang [1 ]
Wang, Pei [1 ]
Li, Jian [1 ]
Xiao, Mingyong [1 ]
Li, Jie [1 ]
Kang, Shengwei [1 ]
Liao, Xiongfei [1 ]
机构
[1] Sichuan Prov Canc Hosp, Dept Radiat Oncol, Chengdu 610041, Sichuan, Peoples R China
来源
RADIATION ONCOLOGY | 2014年 / 9卷
关键词
3-Dimensional conformal radiation therapy; Collapsed cone convolution; Pencil beam convolution; Lung cancer; Monte Carlo; Intensity-modulated radiation therapy; PENCIL-BEAM; DOSIMETRIC VERIFICATION; CALCULATION ALGORITHMS; RADIATION-THERAPY; COLLAPSED CONE; PHOTON BEAMS; IMRT; RADIOTHERAPY; ENERGY; INTERFACES;
D O I
10.1186/s13014-014-0287-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: The accuracy of dose calculation is crucial to the quality of treatment planning and, consequently, to the dose delivered to patients undergoing radiation therapy. Current general calculation algorithms such as Pencil Beam Convolution (PBC) and Collapsed Cone Convolution (CCC) have shortcomings in regard to severe inhomogeneities, particularly in those regions where charged particle equilibrium does not hold. The aim of this study was to evaluate the accuracy of the PBC and CCC algorithms in lung cancer radiotherapy using Monte Carlo (MC) technology. Methods and materials: Four treatment plans were designed using Oncentra Masterplan TPS for each patient. Two intensity-modulated radiation therapy (IMRT) plans were developed using the PBC and CCC algorithms, and two three-dimensional conformal therapy (3DCRT) plans were developed using the PBC and CCC algorithms. The DICOM-RT files of the treatment plans were exported to the Monte Carlo system to recalculate. The dose distributions of GTV, PTV and ipsilateral lung calculated by the TPS and MC were compared. Result: For 3DCRT and IMRT plans, the mean dose differences for GTV between the CCC and MC increased with decreasing of the GTV volume. For IMRT, the mean dose differences were found to be higher than that of 3DCRT. The CCC algorithm overestimated the GTV mean dose by approximately 3% for IMRT. For 3DCRT plans, when the volume of the GTV was greater than 100 cm(3), the mean doses calculated by CCC and MC almost have no difference. PBC shows large deviations from the MC algorithm. For the dose to the ipsilateral lung, the CCC algorithm overestimated the dose to the entire lung, and the PBC algorithm overestimated V-20 but underestimated V-5; the difference in V-10 was not statistically significant. Conclusions: PBC substantially overestimates the dose to the tumour, but the CCC is similar to the MC simulation. It is recommended that the treatment plans for lung cancer be developed using an advanced dose calculation algorithm other than PBC. MC can accurately calculate the dose distribution in lung cancer and can provide a notably effective tool for benchmarking the performance of other dose calculation algorithms within patients.
引用
收藏
页数:9
相关论文
共 50 条
  • [11] Commissioning a fast Monte Carlo dose calculation algorithm for lung cancer treatment planning
    Craig, Jeff
    Oliver, Mike
    Gladwish, Adam
    Mulligan, Matt
    Chen, Jeff
    Wong, Eugene
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2008, 9 (02): : 83 - 97
  • [12] Retrospective monte carlo Dose calculation of Lung treatment plans
    Terjung, B.
    Andratschke, N.
    Kneschaurek, P.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 : 71 - 72
  • [13] Monte Carlo Simulation Dose Calculation for Intensity Modulated Radiosurgery
    Chan, K.
    Schneider, M.
    Smee, R.
    Heng, S.
    Baldock, C.
    [J]. RADIOSURGERY, VOL 7, 2010, 7 : 84 - 94
  • [14] Monte Carlo Simulation Based Dose Calculation in Magnetic Field
    Qi, M.
    Zhou, L.
    Li, Y.
    Song, T.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E558 - E558
  • [15] GPU Accelerated Monte Carlo Simulation for Radiotherapy Dose Calculation
    Zhuge, Y.
    Xie, H.
    Cheng, J.
    Miller, R. W.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S702 - S702
  • [16] Monte Carlo dose calculation for high-accuracy radiation therapy
    Salvat, F.
    Brualla, L.
    Franchisseur, E.
    Kafrouni, H.
    Morrow, S.
    Barthe, J.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2007, 183 : 153 - 153
  • [17] Implementing Monte Carlo Dose Calculation in the Treatment of Non-small Cell Lung Cancer (NSCLC): Clinical Consequences
    van Zyp, N. van der Voort
    Hoogeman, M. S.
    Heijmen, B. J. M.
    Van de Water, S.
    Nuyttens, J. J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S450 - S450
  • [18] Monte Carlo Dose Calculation for Clinical IMRT Treatment Planning
    Siebers, J.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [19] Clinical study to evaluate the dose calculation accuracy for IMRT lung patients
    aljarrah, k.
    Niemierko, A.
    Jiang, S.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2425 - 2425
  • [20] Dose Calculation in Gynecological Brachytherapy using Monte Carlo simulation for intracavitary treatment of Cervical Cancer
    Garcia Contreras, O. J.
    Cristancho, F.
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 452 - 455