Internal atrial defibrillation and implantable atrial defibrillators

被引:0
|
作者
Reuter, DG [1 ]
Ayers, GM [1 ]
机构
[1] InControl Inc, Redmond, WA USA
来源
HEARTWEB | 1999年 / 4卷 / 05期
关键词
atrial fibrillation; implantable atrial defibrillator;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Previous studies have shown that internal atrial defibrillation has been effective for the termination of individual episodes of atrial fibrillation (AF). However, no data exist as to whether repeated internal defibrillation from an implantable atrial defibrillator (IAD) would be safe and effective in maintaining sinus rhythm (NSR) in patients. The IAD philosophy, both in design and from a clinical use perspective is very different as compared to a ventricular ICD, namely, AF is not a life threatening arrhythmia. Therefore, issues such as patient tolerance of therapy versus patient perceived benefit of arrhythmia control become critical for acceptance and use of this therapy. Additionally, for both patient acceptance and safety, an IAD must favor safe and appropriate defibrillation therapy over a very high sensitivity for the arrhythmia. The only single chamber IAD available for clinical use and its 3-leads system (right atrial and coronary sinus defibrillation leads and a right ventricular bipolar lead) has been implanted in the pectoral region in over 180 patients with symptomatic, drug refractory AF. In general, these patients were without significant structural heart disease with an ejection fraction of greater than 40%. Initially, all patients received atrial defibrillation therapy under the observation of the physician. Since completion of the initial clinical trial, patients have had the ability to receive atrial defibrillation therapy in the ambulatory setting. Over 7500 shocks have been delivered from the IAD, more than 350 in the ambulatory setting, without ventricular proarrhythmia. Shock efficacy for spontaneous AF has exceeded 95%. The IAD has been shown to exhibit a high degree of specificity (100%) while maintaining a high sensitivity to AF. Conclusion: The IAD has been operating as intended in these patients. Early clinical results with the IAD have been promising in that the majority of the patients have had multiple AF episodes that have been terminated using the device and have thereby been able to remain in sinus rhythm. Conclusion: The IAD has been operating as intended in these patients. Early clinical results with the IAD have been promising in that the majority of the patients have had multiple AF episodes that have been terminated using the device and have thereby been able to remain in sinus rhythm.
引用
收藏
页码:E41 / E48
页数:8
相关论文
共 50 条
  • [31] SEQUENTIAL PULSE DEFIBRILLATION FOR IMPLANTABLE DEFIBRILLATORS
    BOURLAND, JD
    TACKER, WA
    WESSALE, JL
    KALLOK, MJ
    GRAF, JE
    GEDDES, LA
    MEDICAL INSTRUMENTATION, 1986, 20 (03): : 138 - 142
  • [32] Incidence and mechanism of immediate reinitiation of atrial fibrillation following internal atrial defibrillation
    Timmermans, C
    Rodriguez, LM
    Lambert, H
    Ayers, GM
    Smeets, JLRM
    Wellens, HJJ
    CIRCULATION, 1997, 96 (08) : 1150 - 1150
  • [33] Hemodynamic and cardiorespiratory function following internal atrial defibrillation for chronic atrial fibrillation
    Schimpf, R
    Omran, H
    Jung, W
    Schumacher, B
    Lewalter, T
    MacCarter, D
    Rabahieh, R
    Wolpert, C
    Lüderitz, B
    AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (12): : 1633 - 1637
  • [34] Multichannel mapping of atrial activation sequences after internal atrial defibrillation shocks
    Cooper, RAS
    Smith, WM
    Ideker, RE
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (02) : 82122 - 82122
  • [35] Value of implantable cardioverter-defibrillators in managing atrial fibrillation
    Frisch, Daniel R.
    HEART RHYTHM, 2009, 6 (01) : 9 - 10
  • [36] New generations of implantable pacemaker defibrillators for ventricular and atrial tachyarrhythmias
    Saksena, S
    Prakash, A
    Madan, N
    Giorgberidze, I
    Munsif, AN
    Mathew, P
    Kaushik, R
    Krol, RB
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1996, 89 : 149 - 154
  • [37] Radiofrequency catheter ablation and implantable atrial defibrillators in supraventricular tachycardias
    Jung, W
    Schumacher, B
    Luderitz, B
    MEDIZINISCHE KLINIK, 1997, 92 (04) : 202 - 207
  • [38] Atrial Tachyarrhythmia Prevalence in Patients with Implantable Cardiac Resynchronization Defibrillators
    Gillett, Shane
    Reyes, Chris
    Martin, David
    Lip, Gregory
    JOURNAL OF CARDIAC FAILURE, 2018, 24 (08) : S57 - S57
  • [39] Predictors and outcomes of atrial tachyarrhythmia among patients with implantable defibrillators
    Younis, Arwa
    Heist, E. Kevin
    McNitt, Scott
    Aktas, Mehmet K.
    Rosero, Spencer
    Goldenberg, Ilan
    Kutyifa, Valentina
    HEART RHYTHM, 2020, 17 (04) : 553 - 559
  • [40] Frequency and duration of recurrent asymptomatic and symptomatic episodes of atrial fibrillation in patients with implantable atrial defibrillators
    Jung, W
    Herwig, S
    Spehi, S
    Esmallzadeh, B
    Schneider, C
    Kirchhoff, PG
    Luderitz, B
    CIRCULATION, 1998, 98 (17) : 712 - 712