Internal atrial defibrillation and implantable atrial defibrillators

被引:0
|
作者
Reuter, DG [1 ]
Ayers, GM [1 ]
机构
[1] InControl Inc, Redmond, WA USA
来源
HEARTWEB | 1999年 / 4卷 / 05期
关键词
atrial fibrillation; implantable atrial defibrillator;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Previous studies have shown that internal atrial defibrillation has been effective for the termination of individual episodes of atrial fibrillation (AF). However, no data exist as to whether repeated internal defibrillation from an implantable atrial defibrillator (IAD) would be safe and effective in maintaining sinus rhythm (NSR) in patients. The IAD philosophy, both in design and from a clinical use perspective is very different as compared to a ventricular ICD, namely, AF is not a life threatening arrhythmia. Therefore, issues such as patient tolerance of therapy versus patient perceived benefit of arrhythmia control become critical for acceptance and use of this therapy. Additionally, for both patient acceptance and safety, an IAD must favor safe and appropriate defibrillation therapy over a very high sensitivity for the arrhythmia. The only single chamber IAD available for clinical use and its 3-leads system (right atrial and coronary sinus defibrillation leads and a right ventricular bipolar lead) has been implanted in the pectoral region in over 180 patients with symptomatic, drug refractory AF. In general, these patients were without significant structural heart disease with an ejection fraction of greater than 40%. Initially, all patients received atrial defibrillation therapy under the observation of the physician. Since completion of the initial clinical trial, patients have had the ability to receive atrial defibrillation therapy in the ambulatory setting. Over 7500 shocks have been delivered from the IAD, more than 350 in the ambulatory setting, without ventricular proarrhythmia. Shock efficacy for spontaneous AF has exceeded 95%. The IAD has been shown to exhibit a high degree of specificity (100%) while maintaining a high sensitivity to AF. Conclusion: The IAD has been operating as intended in these patients. Early clinical results with the IAD have been promising in that the majority of the patients have had multiple AF episodes that have been terminated using the device and have thereby been able to remain in sinus rhythm. Conclusion: The IAD has been operating as intended in these patients. Early clinical results with the IAD have been promising in that the majority of the patients have had multiple AF episodes that have been terminated using the device and have thereby been able to remain in sinus rhythm.
引用
收藏
页码:E41 / E48
页数:8
相关论文
共 50 条
  • [21] Internal atrial defibrillation - a new treatment of postoperative atrial fibrillation
    Liebold, A
    Haisch, G
    Rosada, B
    Kleine, P
    THORACIC AND CARDIOVASCULAR SURGEON, 1998, 46 (06): : 323 - 326
  • [22] Internal cardioversion of atrial fibrillation using standard ventricular implantable cardioverter-defibrillators
    Chung, MK
    Niebauer, MJ
    Wilkoff, BL
    Jaeger, FJ
    Kidwell, GA
    Morant, VA
    Tchou, PJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 38A - 38A
  • [23] Current clinical perspectives on implantable devices for atrial defibrillation
    Boriani, G
    Biffi, M
    Martignani, C
    Luceri, R
    Bartolini, P
    Branzi, A
    CURRENT OPINION IN CARDIOLOGY, 2002, 17 (01) : 82 - 89
  • [24] Managing atrial tachyarrhythmias in patients with implantable cardioverter defibrillators
    Schaumann, A
    AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (5B): : 214D - 217D
  • [25] Clinical experience with implantable atrial and combined atrioventricular defibrillators
    Jung, W
    Wolpert, C
    Esmailzadeh, B
    Spehl, S
    Herwig, S
    Schumacher, B
    Lewalter, T
    Omran, H
    Schimpf, R
    Vahlhaus, C
    Welz, A
    Lüderitz, B
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2000, 4 (Suppl 1) : 185 - 195
  • [26] Clinical Experience with Implantable Atrial and Combined Atrioventricular Defibrillators
    Werner Jung
    Christian Wolpert
    Bahman Esmailzadeh
    Susanne Spehl
    Susanne Herwig
    Burghard Schumacher
    Thorsten Lewalter
    Heyder Omran
    Rainer Schimpf
    Christian Vahlhaus
    Arnim Welz
    Berndt Lüderitz
    Journal of Interventional Cardiac Electrophysiology, 2000, 4 : 185 - 195
  • [27] Reproducibility of internal atrial defibrillation threshold in paroxysmal and persistent atrial fibrillation
    Villani, GQ
    Piepoli, MF
    Capucci, A
    EUROPACE, 2004, 6 (04): : 267 - 272
  • [28] External vs internal atrial defibrillation. Influence on atrial function
    Rigo, F
    Raviele, A
    PACEMAKER LEADS 1997, 1997, : 581 - 587
  • [29] Internal atrial defibrillation and detection: clinical results
    Malinowski, K
    Revishvili, AS
    Bieberle, T
    Strobel, JP
    Bolz, A
    Schaldach, M
    EUROPACE '97 - THE OFFICIAL MEETING OF THE WORKING GROUPS ON CARDIAC PACING AND ARRHYTHMIAS OF THE EUROPEAN SOCIETY OF CARDIOLOGY, 1997, : 923 - 928
  • [30] Predictors of atrial defibrillation threshold in internal cardioversion
    Boriani, G
    Biffi, M
    Camanini, C
    Bacchi, L
    Zannoli, R
    Luceri, R
    Branzi, A
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (11): : 1898 - 1901