Concentration of Enteric Viruses in Large Volumes of Water Using a Cartridge-Type Mixed Cellulose Ester Membrane

被引:27
|
作者
Hata, Akihiko [1 ]
Matsumori, Katsuhito [2 ]
Kitajima, Masaaki [3 ]
Katayama, Hiroyuki [2 ]
机构
[1] Kyoto Univ, Res Ctr Environm Qual Management, Otsu, Shiga 5200811, Japan
[2] Univ Tokyo, Grad Sch Engn, Dept Urban Engn, Bunkyo Ku, Tokyo 1138656, Japan
[3] Singapore MIT Alliance Res & Technol, Ctr Environm Sensing & Modeling, Singapore 138602, Singapore
关键词
Virus detection; Poliovirus; Murine norovirus; Environmental water samples; Virus concentration; COMBINED SEWER OVERFLOWS; HEPATITIS-A VIRUS; TAP WATER; ELECTROPOSITIVE FILTER; NORWALK VIRUS; ENTEROVIRUS; NOROVIRUSES; OUTBREAK; PCR; GASTROENTERITIS;
D O I
10.1007/s12560-014-9169-x
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A viral adsorption-elution method using a flat/disk-type electronegative membrane (diameter of 47-90 mm) has been widely utilized to concentrate viruses in relatively small volumes of water (up to 10 L) due to limited filtration area. In the present study, we aimed to develop a virus concentration method that is based on the same principle and yet allows concentration of large volumes of water using a cartridge-type electronegative membrane. We modified two electronegative membrane-based methods for this purpose (i.e., Mg2+ method and Al3+ method) and determined recovery efficiencies of poliovirus and murine norovirus inoculated in water samples. The virus recovery efficiency of the Al3+ method substantially decreased as the volume of water sample increased. In contrast, Mg2+ method showed stable virus recovery efficiencies (10-54 %) even when 40 to 1,000 L of river and tap water samples were processed. The volume of the concentrate (400 mL) can be further reduced to 1.5 mL by a Centricon plus-70 centrifugal ultrafiltration device with overall recovery efficiencies of 8.8-16 %. Our results demonstrated that the newly developed virus concentration method enables detection of as low as 10(1) copies/L of viruses in water samples.
引用
收藏
页码:7 / 13
页数:7
相关论文
共 27 条
  • [21] Highly efficient and sensitive membrane-based concentration process allows quantification, surveillance, and sequencing of viruses in large volumes of wastewater
    El Soufi, G.
    Di Jorio, L.
    Gerber, Z.
    Cluzel, N.
    Van Assche, J.
    Delafoy, D.
    Olaso, R.
    Daviaud, C.
    Loustau, T.
    Schwartz, C.
    Trebouet, D.
    Hernalsteens, O.
    Marechal, V
    Raffestin, S.
    Rousset, D.
    Van Lint, C.
    Deleuze, Jf
    Boni, M.
    Consortium, Obepine
    Rohr, O.
    Villain-Gambier, M.
    Wallet, C.
    WATER RESEARCH, 2024, 249
  • [22] CONCENTRATION OF VIRUSES FROM WATER BY USING CELLULOSE FILTERS MODIFIED BY INSITU PRECIPITATION OF FERRIC AND ALUMINUM HYDROXIDES
    FARRAH, SR
    PRESTON, DR
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1985, 50 (06) : 1502 - 1504
  • [23] Enumeration of faecal indicator bacteria in large water volumes using on site membrane filtration to assess water treatment efficiency
    Hijnen, WAM
    Van Veenendaal, DA
    Van der Speld, WMH
    Visser, A
    Hoogenboezem, W
    Van der Kooij, D
    WATER RESEARCH, 2000, 34 (05) : 1659 - 1665
  • [24] A comparative study on environmental surveillance of enterovirus: Using a two-phase separation method and a filtration method with a mixed cellulose ester (MCE) membrane
    Fang Ling
    Chen Meizhong
    Zhu Shuangli
    Zhang Wei
    Yan Dongmei
    Li Xiaolei
    Huang Shufen
    Li Caixia
    Guo Xue
    Zeng Hanri
    Ke Bixia
    Li Hui
    Xu Wenbo
    Ke Changwen
    Deng Xiaoling
    Zhang Yong
    Zheng Huanying
    生物安全与健康(英文), 2023, 05 (03)
  • [25] A comparative study on environmental surveillance of enterovirus: Using a two-phase separation method and a filtration method with a mixed cellulose ester (MCE) membrane
    Fang, Ling
    Chen, Meizhong
    Zhu, Shuangli
    Zhang, Wei
    Yan, Dongmei
    Li, Xiaolei
    Huang, Shufen
    Li, Caixia
    Guo, Xue
    Zeng, Hanri
    Ke, Bixia
    Li, Hui
    Xu, Wenbo
    Ke, Changwen
    Deng, Xiaoling
    Zhang, Yong
    Zheng, Huanying
    BIOSAFETY AND HEALTH, 2023, 5 (03) : 174 - 180
  • [26] Ultra-Trace Determination of Lead(II) in Water Using Electrothermal Atomic Absorption Spectrometry after Preconcentration by Solid-Phase Extraction to a Small Piece of Cellulose Acetate Type Membrane Filter
    Hitoshi Mizuguchi
    Mirai Ishida
    Tomohiro Takahashi
    Atsushi Sasaki
    Junichi Shida
    Analytical Sciences, 2011, 27 : 85 - 89
  • [27] Ultra-Trace Determination of Lead(II) in Water Using Electrothermal Atomic Absorption Spectrometry after Preconcentration by Solid-Phase Extraction to a Small Piece of Cellulose Acetate Type Membrane Filter
    Mizuguchi, Hitoshi
    Ishida, Mirai
    Takahashi, Tomohiro
    Sasaki, Atsushi
    Shida, Junichi
    ANALYTICAL SCIENCES, 2011, 27 (01) : 85 - 89