Soft X-Ray Spectrometer Using 100-Pixel STJ Detectors for Synchrotron Radiation

被引:14
|
作者
Shiki, Shigetomo [1 ]
Zen, Nobuyuki [1 ]
Ukibe, Masahiro [1 ]
Ohkubo, Masataka [1 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, Tsukuba, Ibaraki 3058568, Japan
来源
关键词
synchrotron radiation; superconducting tunnel junction detector; x-ray absorption fine structure (XAFS);
D O I
10.1063/1.3292365
中图分类号
O59 [应用物理学];
学科分类号
摘要
Fluorescent X-ray absorption fine structure (XAFS) is an important tool for material analysis, especially for the measurement of chemical states or local structures of elements. Semiconductor detectors are usually used for separating the fluorescent of elements in question from background fluorescence. However, the semiconductor detectors cannot always discriminate K-lines of light elements and L-lines of various elements as different X-ray peaks at an energy range below about 3 keV. Superconducting tunnel junction (STJ) detectors are promising device for the soft Xray at synchrotron radiation beam lines because of excellent energy resolution, high detection efficiency, and high counting rate. We are constructing a fluorescent X-ray spectrometer having 100-pixel array of STJs with 200 mu m square. The array detector is mounted on a liquid cryogen-free He-3 cryostat. The sensitive area is the largest among the superconducting X-ray spectrometers operating at synchrotron beam lines. Each pixel is connected to a room temperature readout circuit that consists of a charge sensitive amplifier and a pulse height analyzer. The spectrometer will achieve a total solid angle of similar to 0.01 sr and a maximum counting rate of more than 1M count per second. The present status of developments of our fluorescent X-ray spectrometer was reported.
引用
收藏
页码:409 / 412
页数:4
相关论文
共 50 条
  • [21] Response of the Killed Electrode in STJ X-ray Detectors
    Andrianov, V. A.
    Gorkov, V. P.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2012, 167 (3-4) : 410 - 415
  • [22] Evaluation of soft x-ray multilayer optics using synchrotron radiation
    Hatano, Tadashi
    Seimitsu Kogaku Kaishi/Journal of the Japan Society for Precision Engineering, 2014, 80 (06): : 524 - 527
  • [23] A SPECTROMETER FOR X-RAY ENERGY-DISPERSIVE DIFFRACTION USING SYNCHROTRON RADIATION
    OLSEN, JS
    BURAS, B
    GERWARD, L
    STEENSTRUP, S
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1981, 14 (10): : 1154 - 1158
  • [24] Response of the Killed Electrode in STJ X-ray Detectors
    V. A. Andrianov
    V. P. Gorkov
    Journal of Low Temperature Physics, 2012, 167 : 410 - 415
  • [25] Actinide science with soft x-ray synchrotron radiation
    Shuh, DK
    PLUTONIUM FUTURES-THE SCIENCE, 2000, 532 : 67 - 68
  • [26] Calibration of soft X-ray detection with synchrotron radiation
    Sun, KX
    Yi, RQ
    Jiang, SE
    Yang, JM
    Huang, TX
    Cui, YL
    Yang, GH
    Ding, YK
    Liu, SY
    Zhang, BH
    Wang, HB
    Wen, SH
    Zheng, ZJ
    Jiang, WM
    Zhao, YK
    Cui, MQ
    Zhu, PP
    Zhao, YD
    Li, G
    Zhu, J
    Zheng, L
    Tang, ES
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2004, 28 (02): : 205 - 209
  • [27] A FAST X-RAY ABSORPTION SPECTROMETER FOR USE WITH SYNCHROTRON RADIATION
    MATSUSHITA, T
    PHIZACKERLEY, RP
    JAPANESE JOURNAL OF APPLIED PHYSICS, 1981, 20 (11) : 2223 - 2228
  • [28] Soft x-ray emission spectrometer for undulator radiation
    Rev Sci Instrum, 2 pt 2 (1584):
  • [29] Recent developments in X-ray detectors for synchrotron radiation experiments
    Hall, C.
    Lewis, R.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1994, 348 (2-3): : 627 - 630
  • [30] Calibration and characterization of semiconductor X-ray detectors with synchrotron radiation
    Krumrey, M.
    Gerlach, M.
    Scholze, F.
    Ulm, G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 568 (01): : 364 - 368