Comprehensive quality assurance for the delivery of intensity modulated radiotherapy with a multileaf collimator used in the dynamic mode

被引:148
|
作者
LoSasso, T [1 ]
Chui, CS [1 ]
Ling, CC [1 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10021 USA
关键词
multileaf collimation; intensity modulation; dosimetry; quality assurance;
D O I
10.1118/1.1410123
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The delivery of intensity modulated radiation therapy (IMRT) using dynamic multileaf collimation (DMLC) accounts for about 40% of all treatments on eight multileaf collimator (MLC)-equipped linacs currently at the central and satellite facilities of the Memorial Sloan Kettering Cancer Center (MSKCC). These numbers have been steadily growing for the past 6 years. Treatment with IMRT has been used for a variety of cancers, including tumors of the prostate, head and neck, breast, paraspinal regions, and brain. To ensure that patients are treated in an accurate, efficient, and safe manner, we have developed a comprehensive QA program including mechanical quality assurance, which monitors known potential weaknesses in the MLC device itself, and verification of patient-specific treatments, to confirm the reliability of new software and to identify errors introduced through human interaction with individual patient's plans. This paper presents the reasoning, methodology, and results for mechanical, dosimetric, and electronic tests that are conducted at MSKCC. (C) 2001 American Association of Physicists in Medicine.
引用
收藏
页码:2209 / 2219
页数:11
相关论文
共 50 条
  • [41] Intensity-modulated radiation therapy using a multileaf collimator
    Webb, S
    RADIATION RESEARCH, VOL 2, CONGRESS PROCEEDINGS, 2000, : 660 - 663
  • [42] Impact of the number of control points has on isodose distributions in a dynamic multileaf collimator intensity-modulated radiation therapy delivery
    Goraj, Andrew
    de Boer, Steven F.
    MEDICAL DOSIMETRY, 2012, 37 (04) : 412 - 416
  • [43] Dosimetric effects of multileaf collimator leaf width on intensity-modulated radiotherapy for head and neck cancer
    Ju, S. G.
    Hong, C. S.
    Kim, M. K.
    Kim, J. I.
    Suh, T. S.
    Han, Y. I.
    Ahn, Y. C.
    Choi, D. H.
    Nam, H. R.
    Park, H. C.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S156 - S157
  • [44] Quality assurance of the multileaf collimator with helical tomotherapy: Design and implementation
    Sarkar, Vikren
    Lin, Lan
    Shi, Chengyu
    Papanikolaou, Niko
    MEDICAL PHYSICS, 2007, 34 (07) : 2949 - 2956
  • [45] Delivery of intensity-modulated radiation therapy with a multileaf collimator: Comparison of step-and-shoot and dynamic leaf motion methods
    Chui, CS
    Chan, MF
    Ling, CC
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 460 - 462
  • [46] Impact of the width of multileaf collimator on simultaneous integrated boost intensity-modulated radiotherapy for prostate cancer
    Abe, E.
    Mizowaki, T.
    Norihisa, Y.
    Narita, Y.
    Matsuo, Y.
    Narabayashi, M.
    Nagata, Y.
    Hiraoka, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S577 - S577
  • [47] Dosimetric effects of multileaf collimator leaf width on intensity-modulated radiotherapy for head and neck cancer
    Hong, Chae-Seon
    Ju, Sang Gyu
    Kim, Minkyu
    Kim, Jung-in
    Kim, Jin Man
    Suh, Tae-Suk
    Han, Youngyih
    Ahn, Yong Chan
    Choi, Doo Ho
    Nam, Heerim
    Park, Hee Chul
    MEDICAL PHYSICS, 2014, 41 (02)
  • [48] Commissioning and quality assurance of Euromechanics add-on multileaf collimator
    Rohani, Seyed Aliasghar
    Mahdavi, Seied Rabi
    Mostaar, Ahmad
    Rahimi, Shaghayegh
    Mohammadi, Reza
    Geraily, Ghazale
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2021, 7 (01):
  • [49] The effects of intra-fraction organ motion on the delivery of intensity-modulated field with a multileaf collimator
    Chui, CS
    Yorke, E
    Hong, L
    MEDICAL PHYSICS, 2003, 30 (07) : 1736 - 1746
  • [50] Intensity modulated radiotherapy with dynamic multileaf collimators. Technology and clinical potential
    De Neve, W
    Claus, F
    De Wagter, C
    EUROPEAN JOURNAL OF CANCER, 1999, 35 : S221 - S221