Cerebral blood flow sensitivity to CO2 measured with steady-state and Read's rebreathing methods

被引:28
|
作者
Pandit, JJ
Mohan, RM
Paterson, ND
Poulin, MJ [1 ]
机构
[1] Univ Calgary, Dept Physiol & Biophys, Calgary, AB T2N 4N1, Canada
[2] Univ Oxford, Physiol Lab, Oxford OX1 3PT, England
[3] John Radcliffe Hosp, Nuffield Dept Anaesthet, Oxford OX3 9DU, England
关键词
blood flow; cerebral CO2; carbon dioxide; ventilatory response; cerebral blood flow; control of breathing; ventilatory response to CO2; mammals; humans; methods; rebreathing; steady state CO2 response;
D O I
10.1016/S1569-9048(03)00089-2
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The ventilatory response to carbon dioxide (CO2) measured by the steady-state method is lower than that measured by Read's rebreathing method. A change in end-tidal P-CO2 (PETCO2) results in a lower increment change in brain tissue P-CO2 (Pt-CO2) in the steady-state than with rebreathing: since Pt-CO2 determines the ventilatory response to CO2, the response is lower in the steady-state. If cerebral blood flow (CBF) responds to Pt-CO2, the CBF-CO2 response should be lower in the steady-state than with rebreathing. Six subjects undertook two protocols, (a) steady-state: PETCO2 was held at 1.5 mmHg above normal (isocapnia) for 10 min, then raised to three levels of hypercapnia, (8 min each; 6.5, 11.5 and 16.5 mmHg above normal, separated by 4 min isocapnia). End-tidal Pot was held at 300 mmHg; (b) rebreathing: subjects rebreathed via a 6 L bag filled with 6.5% CO2 in O-2. Transcranial Doppler-derived CBF yielded a higher CBF-CO2 sensitivity in the steady-state than with rebreathing, suggesting that CBF does not respond to Pt-CO2. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 50 条
  • [41] Steady-state design of CO2 pipeline networks for minimal cost per tonne of CO2 avoided
    Weihs, G. A. Fimbres
    Wiley, D. E.
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2012, 8 : 150 - 168
  • [42] END-TIDAL CO2 CONCENTRATION IN STEADY-STATE EXERCISE IN MAN
    MCLOUGHLIN, P
    MCCAFFREY, N
    OREGAN, RG
    IRISH JOURNAL OF MEDICAL SCIENCE, 1986, 155 (09) : 320 - 320
  • [43] ROLE OF METABOLIC CO2 PRODUCTION IN VENTILATORY RESPONSE TO STEADY-STATE EXERCISE
    PHILLIPSON, EA
    BOWES, G
    TOWNSEND, ER
    DUFFIN, J
    COOPER, JD
    JOURNAL OF CLINICAL INVESTIGATION, 1981, 68 (03): : 768 - 774
  • [44] STEADY-STATE VENTILATORY RESPONSE TO CO2 AND BREATHING PATTERNS IN TERM INFANTS
    ZARINETCHI, F
    MACKINNON, BL
    WAGGENER, TB
    PEDIATRIC RESEARCH, 1989, 25 (04) : A333 - A333
  • [45] MODEL OF STEADY-STATE BREATHING AT REST AND RESPONSES TO LOW CO2 LEVELS
    YAMAMOTO, WS
    FEDERATION PROCEEDINGS, 1979, 38 (03) : 990 - 990
  • [46] PULSED AND STEADY-STATE INFRARED EMISSION STUDIES OF CO2 LASER SYSTEMS
    WEBER, MJ
    DEUTSCH, TF
    IEEE JOURNAL OF QUANTUM ELECTRONICS, 1966, QE 2 (09) : 369 - &
  • [47] The stability of cerebrovascular CO2 reactivity following attainment of physiological steady-state
    Carr, Jay M. J. R.
    Caldwell, Hannah G.
    Carter, Howard
    Smith, Kurt
    Tymko, Michael M.
    Green, Daniel J.
    Ainslie, Philip N.
    Hoiland, Ryan L.
    EXPERIMENTAL PHYSIOLOGY, 2021, 106 (12) : 2542 - 2555
  • [48] PULSED AND STEADY-STATE INFRARED EMISSION STUDIES OF CO2 LASER SYSTEMS
    DEUTSCH, TF
    WEBER, MJ
    IEEE JOURNAL OF QUANTUM ELECTRONICS, 1966, QE 2 (04) : R24 - +
  • [49] THE VARIABILITY OF THE VENTILATORY RESPONSE TO STEADY-STATE INHALATION OF CO2 IN PRETERM INFANTS
    ALVAREZ, JE
    ALVARO, RE
    KWIATKOWSKI, K
    CATES, DB
    RIGATTO, H
    PEDIATRIC RESEARCH, 1991, 29 (04) : A307 - A307
  • [50] Steady-state simulation of an automotive air conditioning system running on CO2
    Morais Filho, Pedro P.
    Parise, Jose Alberto R.
    Marques da Silva, Rui P.
    FEDSM 2007: PROCEEDINGS OF THE 5TH JOINT ASME/JSME FLUIDS ENGINEERING SUMMER CONFERENCE, VOL 2, PTS A AND B, 2007, : 1199 - 1204