Cerebral blood flow sensitivity to CO2 measured with steady-state and Read's rebreathing methods

被引:28
|
作者
Pandit, JJ
Mohan, RM
Paterson, ND
Poulin, MJ [1 ]
机构
[1] Univ Calgary, Dept Physiol & Biophys, Calgary, AB T2N 4N1, Canada
[2] Univ Oxford, Physiol Lab, Oxford OX1 3PT, England
[3] John Radcliffe Hosp, Nuffield Dept Anaesthet, Oxford OX3 9DU, England
关键词
blood flow; cerebral CO2; carbon dioxide; ventilatory response; cerebral blood flow; control of breathing; ventilatory response to CO2; mammals; humans; methods; rebreathing; steady state CO2 response;
D O I
10.1016/S1569-9048(03)00089-2
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The ventilatory response to carbon dioxide (CO2) measured by the steady-state method is lower than that measured by Read's rebreathing method. A change in end-tidal P-CO2 (PETCO2) results in a lower increment change in brain tissue P-CO2 (Pt-CO2) in the steady-state than with rebreathing: since Pt-CO2 determines the ventilatory response to CO2, the response is lower in the steady-state. If cerebral blood flow (CBF) responds to Pt-CO2, the CBF-CO2 response should be lower in the steady-state than with rebreathing. Six subjects undertook two protocols, (a) steady-state: PETCO2 was held at 1.5 mmHg above normal (isocapnia) for 10 min, then raised to three levels of hypercapnia, (8 min each; 6.5, 11.5 and 16.5 mmHg above normal, separated by 4 min isocapnia). End-tidal Pot was held at 300 mmHg; (b) rebreathing: subjects rebreathed via a 6 L bag filled with 6.5% CO2 in O-2. Transcranial Doppler-derived CBF yielded a higher CBF-CO2 sensitivity in the steady-state than with rebreathing, suggesting that CBF does not respond to Pt-CO2. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 50 条
  • [21] THE REQUIREMENT FOR CONSTANT ARTERIAL RADIOACTIVITY IN THE (CO2)-O-15 STEADY-STATE BLOOD-FLOW MODEL
    MEYER, E
    YAMAMOTO, YL
    JOURNAL OF NUCLEAR MEDICINE, 1984, 25 (04) : 455 - 460
  • [22] The effect of steady-state CO2 on regional brain blood flow responses to increases in blood pressure via the cold pressor test
    Herrington, Brittney A.
    Thrall, Scott F.
    Mann, Leah M.
    Tymko, Michael M.
    Day, Trevor A.
    AUTONOMIC NEUROSCIENCE-BASIC & CLINICAL, 2019, 222
  • [23] COMPARISON BETWEEN IMPEDANCE CARDIOGRAPHY AND CO2 REBREATHING TECHNIQUES IN MEASUREMENT OF STROKE VOLUME DURING PROLONGED STEADY-STATE EXERCISE
    PISARELLO, J
    OTOOLE, ML
    HILLER, WDB
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1985, 17 (02): : 202 - 202
  • [24] REBREATHING METHODS OF DETERMINING BLOOD CO2 TENSION IN CONGENITAL HEART DISEASE
    OSBORN, JJ
    MACEY, MB
    JOURNAL OF APPLIED PHYSIOLOGY, 1960, 15 (06) : 1159 - 1162
  • [25] STEADY-STATE AND NON-STEADY-STATE CARBONATE SILICATE CONTROLS ON ATMOSPHERIC CO2
    SUNDQUIST, ET
    QUATERNARY SCIENCE REVIEWS, 1991, 10 (2-3) : 283 - 296
  • [26] Bedside pulmonary blood flow measurement via partial CO2 rebreathing
    de Abreu, MG
    Albrecht, DM
    ANASTHESIOLOGIE INTENSIVMEDIZIN NOTFALLMEDIZIN SCHMERZTHERAPIE, 1998, 33 : S22 - S23
  • [27] Steady-state tilt has no effect on cerebrovascular CO2 reactivity in anterior and posterior cerebral circulations
    Tymko, Michael M.
    Skow, Rachel J.
    MacKay, Christina M.
    Day, Trevor A.
    EXPERIMENTAL PHYSIOLOGY, 2015, 100 (07) : 839 - 851
  • [28] STEADY-STATE AND REBREATHING CO2-RESPONSE CURVES COMPARED DURING MORPHINE (MS) ADMINISTRATION
    WARLEY, A
    BOURKE, DL
    FEDERATION PROCEEDINGS, 1985, 44 (03) : 832 - 832
  • [29] Bidirectional CO2 desorption in steady-state CO oxidation on Rh(110)
    Rzeznicka, II
    Matsushima, T
    JOURNAL OF PHYSICAL CHEMISTRY B, 2003, 107 (33): : 8479 - 8483
  • [30] 3 SUCCESSIVE STEADY-STATE CO2-RESPONSE CURVES - NO CHANGE OF SENSITIVITY OF THE VENTILATORY CONTROLLING SYSTEM FOR CO2
    HULSBOSCH, MAM
    BINKHORST, RA
    FOLGERING, HT
    PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1978, 378 (01): : 85 - 86