Part II: Biomechanical assessment for a footprint-restoring transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique

被引:295
|
作者
Park, Maxwell C.
Tibone, James E.
ElAttrache, Neal S.
Ahmad, Christopher S.
Jun, Bong-Jae
Lee, Thay Q.
机构
[1] Kerlan Jobe Orthopaed Clin, Los Angeles, CA USA
[2] Columbia Univ, Med Ctr, Dept Orthopaed Surg, New York, NY USA
[3] VA Long Beach Healthcare Syst, Orthopaed Biomech Lab, Long Beach, CA USA
[4] Univ Calif Irvine, Irvine, CA USA
关键词
D O I
10.1016/j.jse.2006.09.011
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We hypothesized that a transosseous-equivalent repair would demonstrate improved tensile strength and gap formation between the tendon and tuberosity when compared with a double-row technique. In 6 fresh-frozen human shoulders, a transosseous-equivalent rotator cuff repair was performed: a suture limb from each of two medial anchors was bridged over the tendon and fixed laterally with an interference screw. In 6 contralateral matched-pair specimens, a double-row repair was performed. For all repairs, a materials testing machine was used to load each repair cyclically from 10 N to 180 N for 30 cycles; each repair underwent tensile testing to measure failure loads at a deformation rate of I mm/sec. Gap formation between the tendon edge and insertion was measured with a video digitizing system. The mean ultimate load to failure was significantly greater for the transosseous-equivalent technique (443.0 +/- 87.8 N) compared with the double-row technique (299.2 +/- 52.5 N) (P = .043). Gap formation during cyclic loading was not significantly different between the transosseous-equivalent and double-row techniques, with mean values of 3.74 +/- 1.51 mm and 3.79 +/- 0.68 mm, respectively (P = .95). Stiffness for oil cycles was not statistically different between the two constructs (P > .40). The transosseous-equivalent rotator cuff repair technique improves ultimate failure loads when compared with a double-row technique. Gap formation is similar for both techniques. A transosseous-equivalent repair helps restore footprint dimensions and provides a stronger repair than the double-row technique, which may help optimize healing biology.
引用
收藏
页码:469 / 476
页数:8
相关论文
共 50 条
  • [31] The Optimum Tension for Bridging Sutures in Transosseous-Equivalent Rotator Cuff Repair: A Cadaveric Biomechanical Study
    Park, Ji Soon
    McGarry, Michelle H.
    Campbell, Sean T.
    Seo, Hyuk Jun
    Lee, Yeon Soo
    Kim, Sae Hoon
    Lee, Thay Q.
    Oh, Joo Han
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2015, 43 (09): : 2118 - 2125
  • [32] Healing Rates and Functional Outcomes After Triple-Loaded Single-Row Versus Transosseous-Equivalent Double-Row Rotator Cuff Tendon Repair
    Tashjian, Robert Z.
    Granger, Erin K.
    Chalmers, Peter N.
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2018, 6 (11):
  • [33] The Importance of Tear Edge Fixation in Modified Transosseous-Equivalent Rotator Cuff Repair A Biomechanical Study
    Roghani, Reza
    Snir, Nimrod
    Wolfson, Theodore S.
    Rokito, Andrew S.
    BULLETIN OF THE HOSPITAL FOR JOINT DISEASES, 2015, 73 (01): : 10 - 17
  • [34] A Laboratory Comparison of a New Arthroscopic Transosseous Rotator Cuff Repair to a Double Row Transosseous Equivalent Rotator Cuff Repair Using Suture Anchors
    Kummer, Frederick J.
    Hahn, Michael
    Day, Michael
    Meislin, Robert J.
    Jazrawi, Laith M.
    BULLETIN OF THE HOSPITAL FOR JOINT DISEASES, 2013, 71 (02): : 128 - 131
  • [35] Footprint Contact Area and Interface Pressure Comparison Between the Knotless and Knot-Tying Transosseous-Equivalent Technique for Rotator Cuff Repair
    Kim, Sung-Jae
    Kim, Sung-Hwan
    Moon, Hyun-Soo
    Chun, Yong-Min
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2016, 32 (01): : 7 - 12
  • [36] Clinical comparison between double-row and transosseous-equivalent repairs for medium to large size rotator cuff tears
    Jin-Young Park
    Sang-Yoon Lee
    Seok Won Chung
    Hassan Zulkifli
    Jung-Hyun Cho
    Kyung-Soo Oh
    Archives of Orthopaedic and Trauma Surgery, 2013, 133 : 1727 - 1734
  • [37] Biomechanical comparison of knotless wide suture double-row SutureBridge rotator cuff repair to double-row standard suture repair
    Liu, Victor K.
    Bouwmeester, Theresia M.
    Smith, Geoffrey C. S.
    Lam, Patrick H.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2020, 29 (08) : 1621 - 1626
  • [38] Serial MRI evaluation following arthroscopic rotator cuff repair in double-row technique
    Stahnke, Katharina
    Nikulka, Constanze
    Diederichs, Gerd
    Haneveld, Hendrik
    Scheibel, Markus
    Gerhardt, Christian
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2016, 136 (05) : 665 - 672
  • [39] Clinical comparison between double-row and transosseous-equivalent repairs for medium to large size rotator cuff tears
    Park, Jin-Young
    Lee, Sang-Yoon
    Chung, Seok Won
    Zulkifli, Hassan
    Cho, Jung-Hyun
    Oh, Kyung-Soo
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2013, 133 (12) : 1727 - 1734
  • [40] Serial MRI evaluation following arthroscopic rotator cuff repair in double-row technique
    Katharina Stahnke
    Constanze Nikulka
    Gerd Diederichs
    Hendrik Haneveld
    Markus Scheibel
    Christian Gerhardt
    Archives of Orthopaedic and Trauma Surgery, 2016, 136 : 665 - 672