Part II: Biomechanical assessment for a footprint-restoring transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique

被引:295
|
作者
Park, Maxwell C.
Tibone, James E.
ElAttrache, Neal S.
Ahmad, Christopher S.
Jun, Bong-Jae
Lee, Thay Q.
机构
[1] Kerlan Jobe Orthopaed Clin, Los Angeles, CA USA
[2] Columbia Univ, Med Ctr, Dept Orthopaed Surg, New York, NY USA
[3] VA Long Beach Healthcare Syst, Orthopaed Biomech Lab, Long Beach, CA USA
[4] Univ Calif Irvine, Irvine, CA USA
关键词
D O I
10.1016/j.jse.2006.09.011
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We hypothesized that a transosseous-equivalent repair would demonstrate improved tensile strength and gap formation between the tendon and tuberosity when compared with a double-row technique. In 6 fresh-frozen human shoulders, a transosseous-equivalent rotator cuff repair was performed: a suture limb from each of two medial anchors was bridged over the tendon and fixed laterally with an interference screw. In 6 contralateral matched-pair specimens, a double-row repair was performed. For all repairs, a materials testing machine was used to load each repair cyclically from 10 N to 180 N for 30 cycles; each repair underwent tensile testing to measure failure loads at a deformation rate of I mm/sec. Gap formation between the tendon edge and insertion was measured with a video digitizing system. The mean ultimate load to failure was significantly greater for the transosseous-equivalent technique (443.0 +/- 87.8 N) compared with the double-row technique (299.2 +/- 52.5 N) (P = .043). Gap formation during cyclic loading was not significantly different between the transosseous-equivalent and double-row techniques, with mean values of 3.74 +/- 1.51 mm and 3.79 +/- 0.68 mm, respectively (P = .95). Stiffness for oil cycles was not statistically different between the two constructs (P > .40). The transosseous-equivalent rotator cuff repair technique improves ultimate failure loads when compared with a double-row technique. Gap formation is similar for both techniques. A transosseous-equivalent repair helps restore footprint dimensions and provides a stronger repair than the double-row technique, which may help optimize healing biology.
引用
收藏
页码:469 / 476
页数:8
相关论文
共 50 条
  • [21] A Biomechanical Analysis of Point of Failure During Lateral-Row Tensioning in Transosseous-Equivalent Rotator Cuff Repair
    Dierckman, Brian D.
    Goldstein, Jordan L.
    Hammond, Kyle E.
    Karas, Spero G.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2012, 28 (01): : 52 - 58
  • [22] Influence of Rotator Cuff Tear Size and Repair Technique on the Creation and Management of Dog Ear Deformities in a Transosseous-Equivalent Rotator Cuff Repair Model
    Redler, Lauren H.
    Byram, Ian R.
    Luchetti, Timothy J.
    Tsui, Ying Lai
    Moen, Todd C.
    Gardner, Thomas R.
    Ahmad, Christopher S.
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2014, 2 (04):
  • [23] Tripod Technique to Augment Transosseous Equivalent Rotator Cuff Repair
    Gaukroger, A.
    Arnander, M.
    Pearse, Y.
    Tennent, D.
    ARTHROSCOPY TECHNIQUES, 2022, 11 (07): : E1203 - E1208
  • [24] Biomechanical comparison of a single-row versus double-row suture anchor technique for rotator cuff repair
    Kim, DH
    ElAttrachet, NS
    Tibone, JE
    Jun, BJ
    DeLaMora, SN
    Kvitnet, RS
    Lee, TQ
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2006, 34 (03): : 407 - 414
  • [25] Simple Double-Row Rotator Cuff Repair Technique for Large and Massive Cuff Tears
    Funk, Lennard
    Auplish, Sunil
    TECHNIQUES IN SHOULDER AND ELBOW SURGERY, 2009, 10 (01): : 39 - 42
  • [26] Biomechanical Performance of Medial Row Suture Placement Relative to the Musculotendinous Junction in Transosseous Equivalent Suture Bridge Double-Row Rotator Cuff Repair
    Virk, Mandeep S.
    Bruce, Benjamin
    Hussey, Kristen E.
    Thomas, Jacqueline M.
    Luthringer, Tyler A.
    Shewman, Elizabeth F.
    Wang, Vincent M.
    Verma, Nikhil N.
    Romeo, Anthony A.
    Cole, Brian J.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2017, 33 (02): : 242 - 250
  • [27] Does transosseous-equivalent rotator cuff repair biomechanically provide a "self-reinforcement'' effect compared with single-row repair?
    Park, Maxwell C.
    McGarry, Michelle H.
    Gunzenhauser, Robert C.
    Benefiel, Michael K.
    Park, Chong J.
    Lee, Thay Q.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2014, 23 (12) : 1813 - 1821
  • [28] Arthroscopic Double-Row Rotator Cuff Repair Using a Knotless, Interconnected Technique
    Warth, Ryan J.
    Greenspoon, Joshua A.
    Bhatia, Sanjeev
    Millett, Peter J.
    OPERATIVE TECHNIQUES IN ORTHOPAEDICS, 2015, 25 (01) : 43 - 48
  • [29] Double-row arthroscopic rotator cuff repair: Re-establishing the footprint of the rotator cuff
    Lo, IKY
    Burkhart, SS
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2003, 19 (09): : 1035 - 1042
  • [30] Comparison of Passive Stiffness Changes in the Supraspinatus Muscle After Double-Row and Knotless Transosseous-Equivalent Rotator Cuff Repair Techniques: A Cadaveric Study
    Hatta, Taku
    Giambini, Hugo
    Hooke, Alexander W.
    Zhao, Chunfeng
    Sperling, John W.
    Steinmann, Scott P.
    Yamamoto, Nobuyuki
    Itoi, Eiji
    An, Kai-Nan
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2016, 32 (10): : 1973 - 1981