Part II: Biomechanical assessment for a footprint-restoring transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique

被引:295
|
作者
Park, Maxwell C.
Tibone, James E.
ElAttrache, Neal S.
Ahmad, Christopher S.
Jun, Bong-Jae
Lee, Thay Q.
机构
[1] Kerlan Jobe Orthopaed Clin, Los Angeles, CA USA
[2] Columbia Univ, Med Ctr, Dept Orthopaed Surg, New York, NY USA
[3] VA Long Beach Healthcare Syst, Orthopaed Biomech Lab, Long Beach, CA USA
[4] Univ Calif Irvine, Irvine, CA USA
关键词
D O I
10.1016/j.jse.2006.09.011
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We hypothesized that a transosseous-equivalent repair would demonstrate improved tensile strength and gap formation between the tendon and tuberosity when compared with a double-row technique. In 6 fresh-frozen human shoulders, a transosseous-equivalent rotator cuff repair was performed: a suture limb from each of two medial anchors was bridged over the tendon and fixed laterally with an interference screw. In 6 contralateral matched-pair specimens, a double-row repair was performed. For all repairs, a materials testing machine was used to load each repair cyclically from 10 N to 180 N for 30 cycles; each repair underwent tensile testing to measure failure loads at a deformation rate of I mm/sec. Gap formation between the tendon edge and insertion was measured with a video digitizing system. The mean ultimate load to failure was significantly greater for the transosseous-equivalent technique (443.0 +/- 87.8 N) compared with the double-row technique (299.2 +/- 52.5 N) (P = .043). Gap formation during cyclic loading was not significantly different between the transosseous-equivalent and double-row techniques, with mean values of 3.74 +/- 1.51 mm and 3.79 +/- 0.68 mm, respectively (P = .95). Stiffness for oil cycles was not statistically different between the two constructs (P > .40). The transosseous-equivalent rotator cuff repair technique improves ultimate failure loads when compared with a double-row technique. Gap formation is similar for both techniques. A transosseous-equivalent repair helps restore footprint dimensions and provides a stronger repair than the double-row technique, which may help optimize healing biology.
引用
收藏
页码:469 / 476
页数:8
相关论文
共 50 条
  • [1] Part I: Footprint contact characteristics for a transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique
    Park, Maxwell C.
    ElAttrache, Neal S.
    Tibone, James E.
    Ahmad, Christopher S.
    Jun, Bong-Jae
    Lee, Thay Q.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2007, 16 (04) : 461 - 468
  • [2] Transosseous-equivalent rotator cuff repair technique
    Park, Maxwell C.
    ElAttrache, Neal S.
    Ahmad, Christopher S.
    Tibone, James E.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2006, 22 (12): : 1360.e1 - 1360.e5
  • [3] Arthroscopic Rotator Cuff Repair: Double-Row Transosseous Equivalent Suture Bridge Technique
    Abdelshahed, Mina
    Mahure, Siddharth A.
    Kaplan, Daniel J.
    Mollon, Brent
    Zuckerman, Joseph D.
    Kwon, Young W.
    Rokito, Andrew S.
    ARTHROSCOPY TECHNIQUES, 2016, 5 (06): : E1297 - E1304
  • [4] Comparison of the clinical and radiological outcomes of arthroscopic transosseous and transosseous-equivalent double-row rotator cuff repair techniques
    Firat, Ahmet
    Aydin, Mustafa
    Tecimel, Osman
    Ocguder, Ali
    Sanisoglu, Yavuz
    Ugurlu, Mahmut
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2020, 54 (02) : 178 - 185
  • [5] Early Structural and Functional Outcomes for Arthroscopic Double-Row Transosseous-Equivalent Rotator Cuff Repair
    Toussaint, Bruno
    Schnaser, Erik
    Bosley, Jacob
    Lefebvre, Yves
    Gobezie, Reuben
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2011, 39 (06): : 1217 - 1225
  • [6] Does Medial-Row Fixation Technique Affect the Retear Rate and Functional Outcomes After Double-Row Transosseous-Equivalent Rotator Cuff Repair?
    Elbuluk, Ameer M.
    Coxe, Francesca R.
    Fabricant, Peter D.
    Ramos, Nicholas L.
    Alaia, Michael J.
    Jones, Kristofer J.
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2019, 7 (05)
  • [7] Biomechanical comparison of single-row, double-row, and transosseous-equivalent repair techniques after healing in an animal rotator cuff tear model
    Quigley, Ryan J.
    Gupta, Akash
    Oh, Joo-Han
    Chung, Kyung-Chil
    McGarry, Michelle H.
    Gupta, Ranjan
    Tibone, James E.
    Lee, Thay Q.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2013, 31 (08) : 1254 - 1260
  • [8] Transosseous-Equivalent Rotator Cuff Repair: A Systematic Review on the Biomechanical Importance of Tying the Medial Row
    Mall, Nathan A.
    Lee, Andrew S.
    Chahal, Jaskarndip
    Van Thiel, Geoffrey S.
    Romeo, Anthony A.
    Verma, Nikhil N.
    Cole, Brian J.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2013, 29 (02): : 377 - 386
  • [9] Minimum 10-Year Outcomes of Primary Arthroscopic Transosseous-Equivalent Double-Row Rotator Cuff Repair
    Johannsen, Adam M.
    Arner, Justin W.
    Elrick, Bryant P.
    Nolte, Philip-C.
    Rakowski, Dylan R.
    Horan, Marilee P.
    Millett, Peter J.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2021, 49 (08): : 2035 - 2041
  • [10] Double row equivalent for rotator cuff repair: A biomechanical analysis of a new technique
    Robinson, Sean
    Krigbaum, Henry
    Kramer, Jon
    Purviance, Connor
    Parrish, Robin
    Donahue, Joseph
    JOURNAL OF ORTHOPAEDICS, 2018, 15 (02) : 426 - 431