Dosimetric comparison of RapidPlan and manually optimized plans in volumetric modulated arc therapy for prostate cancer

被引:75
|
作者
Kubo, Kazuki [1 ,2 ]
Monzen, Hajime [1 ]
Ishii, Kentaro [2 ]
Tamura, Mikoto [1 ]
Kawamorita, Ryu [2 ]
Sumida, Iori [3 ]
Mizuno, Hirokazu [3 ]
Nishimura, Yasumasa [4 ]
机构
[1] Kindai Univ, Grad Sch Med Sci, Dept Med Phys, 377-2 Ohno Higashi, Osaka 5898511, Japan
[2] Tane Gen Hosp, Dept Radiat Oncol, Nishi Ku, 1-12-21 Kujo Minami, Osaka 5500025, Japan
[3] Osaka Univ, Grad Sch Med, Dept Radiat Oncol, 2-2 Yamada Oka, Suita, Osaka 5650871, Japan
[4] Kindai Univ, Fac Med, Dept Radiat Oncol, 377-2 Ohno Higashi, Osaka 5898511, Japan
基金
日本学术振兴会;
关键词
Knowledge-based planning; RapidPlan; VMAT; Prostate cancer; QUALITY-ASSURANCE; IMRT; VALIDATION; VMAT; RADIOTHERAPY; IMPACT; MODEL;
D O I
10.1016/j.ejmp.2017.06.026
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study evaluated whether RapidPlan based plans (RP plans) created by a single optimization, are usable in volumetric modulated arc therapy (VMAT) for patients with prostate cancer. Methods: We used 51 previously administered VMAT plans to train a RP model. Thirty RP plans were created by a single optimization without planner intervention during optimization. Differences between RP plans and clinical manual optimization (CMO) plans created by an experienced planner for the same patients were analyzed (Wilcoxon tests) in terms of homogeneity index (HI), conformation number (CN), D-95%, and D-2% to planning target volume (PTV), mean dose, V-50Gy, V-70Gy, V-75Gy, and V-78Gy to rectum and bladder, monitor unit (MU), and multi-leaf collimator (MLC) sequence complexity. Results: RP and CMO values for PTV D-95%, PTV D-2%, HI, and CN were significantly similar (p < 0.05 for all). RP mean dose, V-50Gy, and V-70Gy to rectum were superior or comparable to CMO values; RP V-75Gy and V-78Gy were higher than in CMO plans (p < 0.05). RP bladder dose-volume parameter values (except V-78Gy) were lower than in CMO plans (p < 0.05). MU values were RP: 730 +/- 55 MU and CMO: 580 +/- 37 MU (p < 0.05); and MLC sequence complexity scores were RP: 0.25 +/- 0.02 and CMO: 0.35 +/- 0.03 (p < 0.05). Conclusions: RP plans created by a single optimization were clinically acceptable in VMAT for patient with prostate cancer. Our simple model could reduce optimization time, independently of planner's skill and knowledge. (C) 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:199 / 204
页数:6
相关论文
共 50 条
  • [1] Dosimetric comparison of RapidPlan and manually optimised volumetric modulated arc therapy plans in prostate cancer
    Chua, Loyce M. H.
    Pang, Eric P. P.
    Master, Zubin
    Sultana, Rehena
    Tuan, Jeffrey K. L.
    Bragg, Christopher M.
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2021, 20 (03) : 257 - 264
  • [2] Dosimetric Comparison of RapidPlan and Manually Optimized Plans in IMRT for Postoperative Left Breast Cancer
    Sun, T.
    Lin, X.
    Yin, Y.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E291 - E291
  • [3] Dosimetry Comparison Between In-House RapidPlan, Varian Supplied Model and Manually Optimized Plans in Volumetric Arc Radiotherapy of Prostate Cancer
    Ozer, M.
    Reynolds, T.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E208 - E208
  • [4] A dosimetric comparison of volumetric modulated arc therapy with step-and-shoot intensity modulated radiation therapy for prostate cancer
    Mellon, Eric A.
    Javedan, Khosrow
    Strom, Tobin J.
    Moros, Eduardo G.
    Biagioli, Matthew C.
    Fernandez, Daniel C.
    Wasserman, Stu G.
    Wilder, Richard B.
    [J]. PRACTICAL RADIATION ONCOLOGY, 2015, 5 (01) : 11 - 15
  • [5] Dosimetric comparison of volumetric modulated arc therapy and intensity modulated radiation therapy for anal cancer
    Chiang, Bing-Hao
    Hibbitts, Kerry
    Ortega, Heather
    Herman, Terence
    Ahmad, Salahuddin
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2020, 19 (02) : 190 - 192
  • [6] Validation of RapidPlan knowledge-based model for volumetric-modulated arc therapy in prostate cancer
    Ayuthaya, Isra Israngkul Na
    Suriyapee, Sivalee
    Sanghangthum, Taweap
    [J]. JOURNAL OF MEDICAL PHYSICS, 2022, 47 (03) : 250 - 255
  • [7] Dosimetric comparison of intensity modulated and volumetric arc radiation therapy for gastric cancer
    Li, Zhiping
    Zeng, Jianshuang
    Wang, Zi
    Zhu, Hong
    Wei, Yuquan
    [J]. ONCOLOGY LETTERS, 2014, 8 (04) : 1427 - 1434
  • [8] Dosimetric effect of body contour changes for prostate and head and neck volumetric modulated arc therapy plans
    Sun, Lingyue
    Kirkby, Charles
    Smith, Wendy
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (04): : 115 - 124
  • [9] Assessment of Robustly Optimized Intensity Modulated Proton Therapy and Volumetric Modulated Arc Therapy for Prostate Cancer
    Brovold, N.
    King, A.
    Xu, Y.
    Diwanji, T.
    Pollack, A.
    Dogan, N.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E625 - E625
  • [10] Volumetric modulated arc therapy for prostate cancer
    Afghan, M. K. N.
    Cao, D.
    Mehta, V.
    Wong, T.
    Ye, J.
    Shepard, D.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S665 - S666