Near-Infrared Fiber Imager for the VLTI

被引:1
|
作者
Neuhaeuser, Ralph [1 ,7 ]
Tuennermann, Andreas [2 ]
Hempel, Marc [1 ,7 ]
Stecklum, Bringfried [3 ]
Ruske, Jena-Peter [4 ]
Guenther, Eike [3 ]
Hatzes, Artie [3 ]
Chini, Rolf [5 ]
Lemke, Roland [5 ]
Wuchterl, Guenther [1 ,7 ]
von der Luehe, Oskar [6 ]
机构
[1] Inst Astrophys, Schillergasschen 2, D-07745 Jena, Germany
[2] Univ Jena, Inst Appl Phys, D-07745 Jena, Germany
[3] Thuringer Landessternwarte Tautenburg, D-07778 Tautenburg, Germany
[4] GC Tec, D-07745 Jena, Germany
[5] Ruhr Univ Bochum, Astron Inst, D-44780 Bochum, Germany
[6] Kiepenheuer Inst Sonnenphys, D-79104 Freiberg, Germany
[7] Univ Sternwarte, D-07745 Jena, Germany
关键词
D O I
10.1007/978-3-540-74256-2_49
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
For detection of massive close-in exo-planets around other stars, a contrast of similar to 0.3% is sufficient and can be achieved with state-of-the-art single-mode fibers as spatial filter. For lower-mass planets, much higher accuracy is neccessary. Apart from the atmosphere, there are several sources of noise which degrade the phase stability of interferometers based on bulk optics by changes in the optical path. For direct detection of low-mass exo-planets and for direct observation of convection on giant stars, our two main science goals, as well as for secondary science goals such as lower-mass faint circumstellar disks around both nearby low-mass stars as well as more distant high-mass stars and for the direct detection of close spectroscopic binary (T Tauri) stars and to follow their orbits for direct dynamical mass determination, we need more than two apertures to fill the uv-plane, again very complicated with bulk-optics. Integrated optics allows to solve these problems and to minimize the components. We have experiences in the development and fabrication of integrated-optical circuits and modulators in various wavelength ranges, i.e. from visible to the telecommunication band, as well as integrated-optical sensor systems like interferometers. Starting from two channel interferometers for the J-band at 1.55 mu m based on Lithiumniobat, we will develop multi-channel-interferometer systems for longer wavelengths. Such systems with new materials and fibers for the near- and thermal infrared can then be used, e.g., for 2nd Gen VLTI instrumentation.
引用
收藏
页码:419 / 429
页数:11
相关论文
共 50 条
  • [31] Near-infrared interferometric observation of the Herbig Ae star HD 144432 with VLTI/AMBER
    Chen, L.
    Kreplin, A.
    Wang, Y.
    Weigelt, G.
    Hofmann, K. -H.
    Kraus, S.
    Schertl, D.
    Lagarde, S.
    Natta, A.
    Petrov, R.
    Robbe-Dubois, S.
    Tatulli, E.
    ASTRONOMY & ASTROPHYSICS, 2012, 541
  • [32] FIBER OPTIC LASERS AND AMPLIFIERS FOR THE NEAR-INFRARED
    MINISCALCO, WJ
    ANDREWS, LJ
    HALIDE GLASSES V, 1988, 32 : 501 - 510
  • [33] CALIBRATION IN THE FIBER OPTIC REGION OF THE NEAR-INFRARED
    TENGE, B
    BUCHANAN, BR
    HONIGS, DE
    APPLIED SPECTROSCOPY, 1987, 41 (05) : 779 - 785
  • [34] AMBER, the near-infrared spectro-interferometric three-telescope VLTI instrument
    Petrov, R. G.
    Malbet, F.
    Weigelt, G.
    Antonelli, P.
    Beckmann, U.
    Bresson, Y.
    Chelli, A.
    Dugue, M.
    Duvert, G.
    Gennari, S.
    Gluck, L.
    Kern, P.
    Lagarde, S.
    Le Coarer, E.
    Lisi, F.
    Millour, F.
    Perraut, K.
    Puget, P.
    Rantakyro, F.
    Robbe-Dubois, S.
    Roussel, A.
    Salinari, P.
    Tatulli, E.
    Zins, G.
    Accardo, M.
    Acke, B.
    Agabi, K.
    Altariba, E.
    Arezki, B.
    Aristidi, E.
    Baffa, C.
    Behrend, J.
    Bloecker, T.
    Bonhomme, S.
    Busoni, S.
    Cassaing, F.
    Clausse, J. -M.
    Colin, J.
    Connot, C.
    Delboulbe, A.
    de Souza, A. Domiciano
    Driebe, T.
    Feautrier, P.
    Ferruzzi, D.
    Forveille, T.
    Fossat, E.
    Foy, R.
    Fraix-Burnet, D.
    Gallardo, A.
    Giani, E.
    ASTRONOMY & ASTROPHYSICS, 2007, 464 (01) : 1 - 12
  • [35] NEAR-INFRARED OXIMETRY AND NEAR-INFRARED SPECTROSCOPY
    OWENREECE, H
    ELWELL, CE
    FALLON, P
    GOLDSTONE, J
    SMITH, M
    ANAESTHESIA, 1994, 49 (12) : 1102 - 1103
  • [36] Installation and Commissioning of the LINC-NIRVANA Near-Infrared MCAO Imager on LBT
    Herbst, T. M.
    Bertram, Thomas
    Arcidiacono, Carmelo
    Bergomi, Maria
    Berwein, Juergen
    Bizenberger, Peter
    Briegel, Florian
    Farinato, Jacopo
    Klettke, Micah
    Marafatto, Luca
    Mathar, Richard
    McGurk, Rosalie
    Ragazzoni, Roberto
    Santhakumari, Kalyan K. R.
    Viotto, Valentina
    GROUND-BASED AND AIRBORNE INSTRUMENTATION FOR ASTRONOMY VII, 2018, 10702
  • [37] A near-infrared colloidal quantum dot imager with monolithically integrated readout circuitry
    Jing Liu
    Peilin Liu
    Dengyang Chen
    Tailong Shi
    Xixi Qu
    Long Chen
    Tong Wu
    Jiangping Ke
    Kao Xiong
    Mingyu Li
    Haisheng Song
    Wei Wei
    Junkai Cao
    Jianbing Zhang
    Liang Gao
    Jiang Tang
    Nature Electronics, 2022, 5 : 443 - 451
  • [38] MOSFIRIE: a multi-object near-infrared spectrograph and imager for the Keck Observatory
    McLean, Ian S.
    Steidel, Charles C.
    Matthews, Keith
    Epps, Harland
    Adkins, Sean M.
    GROUND-BASED AND AIRBORNE INSTRUMENTATION FOR ASTRONOMY II, PTS 1-4, 2008, 7014
  • [39] Real time functional near-infrared imager and imaging of human brain activity
    Luo, QM
    Zeng, SQ
    Gong, H
    Chen, WG
    Zhang, Z
    Chance, B
    OPTICAL AND IMAGING TECHNIQUES FOR BIOMONITORING IV, PROCEEDINGS OF, 1999, 3567 : 65 - 69
  • [40] Experimental evaluation of a hyperspectral imager for near-infrared fluorescent contrast agent studies
    Luthman, A. Siri
    Bohndiek, Sarah E.
    OPTICAL BIOPSY XIII: TOWARD REAL-TIME SPECTROSCOPIC IMAGING AND DIAGNOSIS, 2015, 9318