Near-Infrared Fiber Imager for the VLTI

被引:1
|
作者
Neuhaeuser, Ralph [1 ,7 ]
Tuennermann, Andreas [2 ]
Hempel, Marc [1 ,7 ]
Stecklum, Bringfried [3 ]
Ruske, Jena-Peter [4 ]
Guenther, Eike [3 ]
Hatzes, Artie [3 ]
Chini, Rolf [5 ]
Lemke, Roland [5 ]
Wuchterl, Guenther [1 ,7 ]
von der Luehe, Oskar [6 ]
机构
[1] Inst Astrophys, Schillergasschen 2, D-07745 Jena, Germany
[2] Univ Jena, Inst Appl Phys, D-07745 Jena, Germany
[3] Thuringer Landessternwarte Tautenburg, D-07778 Tautenburg, Germany
[4] GC Tec, D-07745 Jena, Germany
[5] Ruhr Univ Bochum, Astron Inst, D-44780 Bochum, Germany
[6] Kiepenheuer Inst Sonnenphys, D-79104 Freiberg, Germany
[7] Univ Sternwarte, D-07745 Jena, Germany
关键词
D O I
10.1007/978-3-540-74256-2_49
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
For detection of massive close-in exo-planets around other stars, a contrast of similar to 0.3% is sufficient and can be achieved with state-of-the-art single-mode fibers as spatial filter. For lower-mass planets, much higher accuracy is neccessary. Apart from the atmosphere, there are several sources of noise which degrade the phase stability of interferometers based on bulk optics by changes in the optical path. For direct detection of low-mass exo-planets and for direct observation of convection on giant stars, our two main science goals, as well as for secondary science goals such as lower-mass faint circumstellar disks around both nearby low-mass stars as well as more distant high-mass stars and for the direct detection of close spectroscopic binary (T Tauri) stars and to follow their orbits for direct dynamical mass determination, we need more than two apertures to fill the uv-plane, again very complicated with bulk-optics. Integrated optics allows to solve these problems and to minimize the components. We have experiences in the development and fabrication of integrated-optical circuits and modulators in various wavelength ranges, i.e. from visible to the telecommunication band, as well as integrated-optical sensor systems like interferometers. Starting from two channel interferometers for the J-band at 1.55 mu m based on Lithiumniobat, we will develop multi-channel-interferometer systems for longer wavelengths. Such systems with new materials and fibers for the near- and thermal infrared can then be used, e.g., for 2nd Gen VLTI instrumentation.
引用
收藏
页码:419 / 429
页数:11
相关论文
共 50 条
  • [21] Interferometric observations of the Mira star o Ceti with the VLTI/VINCI instrument in the near-infrared
    Driebe, T.
    Woodruff, H. C.
    Eberhardt, M.
    Hofmann, K. -H.
    Ohnaka, K.
    Richichi, A.
    Schertl, D.
    Schoeller, M.
    Scholz, M.
    Weigelt, G.
    Wittkowski, M.
    Wood, P. R.
    POWER OF OPTICAL/IR INTERFEROMETRY: RECENT SCIENTIFIC RESULTS AND 2ND GENERATION INSTRUMENTATION, 2008, : 503 - +
  • [22] Interferometric observations of the mira star O ceti with the VLTI/VINCI instrument in the near-infrared
    Hofmann, KH
    Eberhardt, M
    Driebe, T
    Schertl, D
    Scholz, M
    Schoeller, M
    Weigelt, G
    Wittkowski, M
    Woodruff, HC
    PROCEEDINGS OF THE 13TH CAMBRIDGE WORKSHOP ON COOL STARS, STELLAR SYSTEMS AND THE SUN - PROCEEDINGS, VOLS 1 AND 2, 2005, 560 : 651 - 655
  • [23] Interferometric observations of the Mira star o Ceti with the VLTI/VINCI instrument in the near-infrared
    Woodruff, HC
    Eberhardt, M
    Driebe, T
    Hofmann, KH
    Ohnaka, K
    Richichi, A
    Schertl, D
    Schöller, M
    Scholz, M
    Weigelt, S
    Wittkowski, M
    Wood, PR
    NEW FRONTIERS IN STELLAR INTERFEROMETRY, PTS 1-3, 2004, 5491 : 1707 - 1713
  • [24] Optical aspects of Near-Infrared Imager Spectrometer and Polarimeter instrument (NISP)
    Rai, Archita
    Ganesh, Shashikiran
    Paul, Sukamal
    Kasarla, Prashanth K.
    Prajapati, Prachi, V
    Sarkar, Deekshya R.
    Singh, Alka
    Patwal, Pitambar S.
    Adalja, Hitesh K. L.
    Mathur, Satya N.
    Naik, Sachindra
    Shah, Amish B.
    Baliyan, Kiran S.
    GROUND-BASED AND AIRBORNE INSTRUMENTATION FOR ASTRONOMY VIII, 2020, 11447
  • [25] Interferometric observations of the Mira star o Ceti with the VLTI/VINCI instrument in the near-infrared
    Max-Planck-Inst. F. Radioastronomie, Auf dem Hügel 69, D-53321 Bonn, Germany
    不详
    不详
    不详
    不详
    不详
    SPIE - The International Society for Optical Engineering, 1600, 1707-1713 (2004):
  • [26] Development and Phantom study on Near-Infrared Diffuse Optical Tomographic Imager
    Sathya, A.
    Deepan, T.
    Elliot, Jim C.
    Jeeva, J. B.
    MATERIALS TODAY-PROCEEDINGS, 2019, 15 : 309 - 315
  • [27] Interferometric observations of the Mira star o Ceti with the VLTI/VINCI instrument in the near-infrared
    Woodruff, HC
    Eberhardt, M
    Driebe, T
    Hofmann, KH
    Ohnaka, K
    Richichi, A
    Schertl, D
    Schöller, M
    Scholz, M
    Weigelt, G
    Wittkowski, M
    Wood, PR
    ASTRONOMY & ASTROPHYSICS, 2004, 421 (02) : 703 - 714
  • [28] Near-infrared coronagraph imager on the Subaru 8m telescope
    Murakawa, K
    Suto, H
    Tamura, M
    Takami, H
    Takato, N
    Hayashi, SS
    Doi, Y
    Kaifu, N
    Hayano, Y
    Gaessler, W
    Kamata, Y
    INSTRUMENT DESIGN AND PERFORMANCE FOR OPTICAL/INFRARED GROUND-BASED TELESCOPES, PTS 1-3, 2003, 4841 : 881 - 888
  • [29] Portable near-infrared diffusive light imager for breast cancer detection
    Chen, NG
    Huang, MM
    Xia, HJ
    Piao, DQ
    Cronin, E
    Zhu, Q
    JOURNAL OF BIOMEDICAL OPTICS, 2004, 9 (03) : 504 - 510
  • [30] Mimir: A near-infrared wide-field imager, spectrometer, and polarimeter
    Clemens, D. P.
    Sarcia, D.
    Grabau, A.
    Tollestrup, E. V.
    Buie, M. W.
    Dunham, E.
    Taylor, B.
    PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF THE PACIFIC, 2007, 119 (862) : 1385 - 1402