General thermodynamic performance of irreversible absorption heat pump

被引:15
|
作者
Zhao Xiling [1 ]
Fu Lin [1 ]
Zhang Shigang [1 ]
机构
[1] Tsinghua Univ, Dept Bldg Sci, Beijing 100084, Peoples R China
关键词
Absorption heat pump; Irreversible; General performance; Thermodynamics; REFRIGERATORS; SYSTEMS;
D O I
10.1016/j.enconman.2010.07.023
中图分类号
O414.1 [热力学];
学科分类号
摘要
The absorption heat pump (AHP) was studied with thermodynamics. A four reservoirs model of absorption heat pump was established considering the heat resistance, heat leak and the internal irreversibility. The reasonable working regions, the performance effects of irreversibility, heat leak and the correlation of four components were studied. When studying the effects of internal irreversibility, two internal irreversibility parameters (I(he) for generator-absorber assembly and I(re) for evaporator-condenser assembly) were introduced to distinguish the different effects. When studying the heat transfer relations of four components, a universal relationship between the main parameters were deduced. The results which have more realized meaning show that, the reduction of the friction, heat loss, and internal dissipations of the evaporator-condenser assembly are more important than its reduction of generator-absorber assembly, and lessening the heat leak of generator are more important than its reduction of other components to improve the AHP performance. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:494 / 499
页数:6
相关论文
共 50 条
  • [21] Performance evaluation of irreversible Stirling and Ericsson heat pump cycles
    Kaushik, SC
    Tyagi, SK
    Bose, SK
    Singhal, MK
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2002, 41 (02) : 193 - 200
  • [22] Performance evaluation of irreversible cascaded refrigeration and heat pump cycles
    Kaushik, SC
    Kumar, P
    Jain, S
    ENERGY CONVERSION AND MANAGEMENT, 2002, 43 (17) : 2405 - 2424
  • [23] General performance of an irreversible three heat source refrigerator
    Bautista, O
    Méndez, F
    ENERGY CONVERSION AND MANAGEMENT, 2005, 46 (03) : 433 - 449
  • [24] Effect of heat transfer law on the performance of a generalized irreversible Carnot heat pump
    Ni, N
    Chen, L
    Sun, F
    Wu, C
    JOURNAL OF THE INSTITUTE OF ENERGY, 1999, 72 (491): : 64 - 68
  • [25] Effect of heat transfer law on the performance of a generalized irreversible Carnot heat pump
    Ni, N.
    Chen, L.
    Sun, F.
    Wu, C.
    Journal of the Institute of Energy, 72 (491): : 64 - 68
  • [26] THERMODYNAMIC CRITERIA FOR OPTIMAL ABSORPTION HEAT-PUMP MEDIA
    NARODOSLAWSKY, M
    OTTER, G
    MOSER, F
    HEAT RECOVERY SYSTEMS & CHP, 1988, 8 (03): : 221 - 233
  • [27] ON THE PERFORMANCE OF ABSORPTION HEAT PUMP-TRANSFORMERS
    TUFANO, V
    HEAT RECOVERY SYSTEMS & CHP, 1995, 15 (04): : 327 - 332
  • [28] Optimal performance of irreversible absorption refrigerator with four heat sources
    Li, Z. J.
    Zhu, W. F.
    Chen, J. P.
    Wang, F.
    Bai, T.
    Han, Z. W.
    Kong, F. H.
    Zheng, M. Y.
    JOURNAL OF THE ENERGY INSTITUTE, 2010, 83 (01) : 56 - 62
  • [29] Performance analysis of irreversible energy selective electron (ESE) heat pump with heat leakage
    Ding, Z. M.
    Chen, L. G.
    Sun, F. R.
    JOURNAL OF THE ENERGY INSTITUTE, 2012, 85 (04) : 227 - 235
  • [30] Optimum performance of a generalized irreversible carnot heat pump with a generalized heat transfer law
    Zhu, XQ
    Chen, LG
    Sun, FR
    Wu, C
    PHYSICA SCRIPTA, 2001, 64 (06) : 584 - 587