Performance evaluation of irreversible Stirling and Ericsson heat pump cycles

被引:24
|
作者
Kaushik, SC
Tyagi, SK
Bose, SK
Singhal, MK
机构
[1] Indian Inst Technol, Ctr Energy Studies, New Delhi 110016, India
[2] SSV PG Coll, Dept Phys, Ghaziabad, Uttar Pradesh, India
关键词
internal and external irreversibilities; Stirling and Ericsson heat pumps; optimum performance; heating load; power input; Lagrangian multiplier;
D O I
10.1016/S1290-0729(01)01297-2
中图分类号
O414.1 [热力学];
学科分类号
摘要
This communication presents the performance evaluation of irreversible Stirling and Ericsson Heat Pumps Cycles including external and internal irreversibilities along with finite heat capacities of external reservoirs. The external irreversibility is due to finite temperature difference between working fluid and external (source/sink) reservoirs fluid while the internal irreversibilities are due to regenerative heat loss and other entropy generation in the cycle. The heating load is maximized for the given power input. The heating coefficient of performance, the heat transfers to and from the heat pumps and the working fluid temperatures at these conditions have been evaluated. The effect of different parameters (reservoirs temperature, the various effectivenesses and irreversibility parameter), on the performance of these cycles have been studied. It is found that the effect of internal irreversibility parameter is more pronounced than that of other external irreversibility parameters. (C) 2002 Editions scientifiques et medicales Elsevier SAS. All rights reserved.
引用
收藏
页码:193 / 200
页数:8
相关论文
共 50 条
  • [1] Ecological optimization and performance study of irreversible Stirling and Ericsson heat engines
    Tyagi, SK
    Kaushik, SC
    Salhotra, R
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2002, 35 (20) : 2668 - 2675
  • [2] Finite time thermodynamic evaluation of irreversible Ericsson and Stirling heat engines
    Kaushik, SC
    Kumar, S
    ENERGY CONVERSION AND MANAGEMENT, 2001, 42 (03) : 295 - 312
  • [3] Parametric study of irreversible Stirling and Ericsson cryogenic refrigeration cycles
    Tyagi, SK
    Kaushik, SC
    Singhal, MK
    ENERGY CONVERSION AND MANAGEMENT, 2002, 43 (17) : 2297 - 2309
  • [4] Performance evaluation of irreversible cascaded refrigeration and heat pump cycles
    Kaushik, SC
    Kumar, P
    Jain, S
    ENERGY CONVERSION AND MANAGEMENT, 2002, 43 (17) : 2405 - 2424
  • [5] On the performance of irreversible combined heat pump cycles
    Chen, JC
    Yan, ZJ
    Chen, LX
    Andresen, B
    OCOS 2000: FROM THERMO-ECONOMICS TO SUSTAINABILITY, PTS 1-4, 2000, : 269 - 277
  • [6] The performance of irreversible combined heat-pump cycles
    Goktun, S
    Yavuz, H
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1997, 30 (20) : 2848 - 2852
  • [7] Performance characteristics and parametric optimization of an irreversible magnetic Ericsson heat-pump
    Wei, Fang
    Lin, Guoxing
    Chen, Jincan
    Bruck, Ekkes
    PHYSICA B-CONDENSED MATTER, 2011, 406 (03) : 633 - 639
  • [8] Performance evaluation of an irreversible Stirling heat engine cycle
    Kaushik, S.C., 1600, Ambient Press Ltd (24):
  • [9] Ecological optimization and parametric study of irreversible Stirling and Ericsson heat pumps
    Tyagi, SK
    Kaushik, SC
    Salohtra, R
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2002, 35 (16) : 2058 - 2065
  • [10] Thermoeconomic analysis of an irreversible Stirling heat pump cycle
    U. Lucia
    G. Gervino
    The European Physical Journal B - Condensed Matter and Complex Systems, 2006, 50 : 367 - 369