Performance evaluation of irreversible Stirling and Ericsson heat pump cycles

被引:24
|
作者
Kaushik, SC
Tyagi, SK
Bose, SK
Singhal, MK
机构
[1] Indian Inst Technol, Ctr Energy Studies, New Delhi 110016, India
[2] SSV PG Coll, Dept Phys, Ghaziabad, Uttar Pradesh, India
关键词
internal and external irreversibilities; Stirling and Ericsson heat pumps; optimum performance; heating load; power input; Lagrangian multiplier;
D O I
10.1016/S1290-0729(01)01297-2
中图分类号
O414.1 [热力学];
学科分类号
摘要
This communication presents the performance evaluation of irreversible Stirling and Ericsson Heat Pumps Cycles including external and internal irreversibilities along with finite heat capacities of external reservoirs. The external irreversibility is due to finite temperature difference between working fluid and external (source/sink) reservoirs fluid while the internal irreversibilities are due to regenerative heat loss and other entropy generation in the cycle. The heating load is maximized for the given power input. The heating coefficient of performance, the heat transfers to and from the heat pumps and the working fluid temperatures at these conditions have been evaluated. The effect of different parameters (reservoirs temperature, the various effectivenesses and irreversibility parameter), on the performance of these cycles have been studied. It is found that the effect of internal irreversibility parameter is more pronounced than that of other external irreversibility parameters. (C) 2002 Editions scientifiques et medicales Elsevier SAS. All rights reserved.
引用
收藏
页码:193 / 200
页数:8
相关论文
共 50 条
  • [32] Application of the Direct Method to irreversible Stirling cycles with finite speed
    Petrescu, S
    Costea, M
    Harman, C
    Florea, T
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2002, 26 (07) : 589 - 609
  • [33] Irreversible absorption heat-pump and its optimal performance
    Chen, LG
    Qin, XY
    Sun, FR
    Wu, C
    APPLIED ENERGY, 2005, 81 (01) : 55 - 71
  • [34] Dynamics of an oscillating Stirling heat pump
    Barreno, I.
    Costa, S. C.
    Cordon, M.
    Urrutibeascoa, I.
    Gomez, X.
    Mateos, M.
    APPLIED ENERGY, 2014, 136 : 704 - 711
  • [35] Effect of heat transfer law on the performance of a generalized irreversible Carnot heat pump
    Ni, N
    Chen, L
    Sun, F
    Wu, C
    JOURNAL OF THE INSTITUTE OF ENERGY, 1999, 72 (491): : 64 - 68
  • [36] Effect of heat transfer law on the performance of a generalized irreversible Carnot heat pump
    Ni, N.
    Chen, L.
    Sun, F.
    Wu, C.
    Journal of the Institute of Energy, 72 (491): : 64 - 68
  • [37] Performance optimization for an irreversible quantum Stirling cooler
    Zhuming Huang
    Feng Wu
    Lingen Chen
    Chih Wu
    Fangzhong Guo
    Journal of Thermal Science, 2002, 11 : 193 - 197
  • [38] Performance Optimization for an Irreversible Quantum Stirling Cooler
    Huang, Zhuming
    Wu, Feng
    Chen, Lingen
    Wu, Chih
    Guo, Fangzhong
    JOURNAL OF THERMAL SCIENCE, 2002, 11 (03) : 193 - 197
  • [39] Performance Optimization for an Irreversible Quantum Stirling Cooler
    Zhuming Huang Feng Wu Lingen Chen Chih Wu Fangzhong GuoDepartment of Physics and Heat Engineering
    E-mail: wufeng@mail.whict.edu.cn Faculty 306
    Journal of Thermal Science, 2002, (03) : 193 - 197
  • [40] Optimal performance analysis of irreversible cycles used as heat pumps and refrigerators
    Chen, JC
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1997, 30 (04) : 582 - 587