Characterization of PET Data Acquisition System with Compressed Sensing Detectors

被引:0
|
作者
Chang, Chen-Ming [1 ]
Olcott, Peter D. [1 ]
Hong, Key Jo [1 ]
Grant, Alexander M. [1 ]
Lee, Brian J. [1 ]
Kim, Ealgoo [1 ]
Levin, Craig S.
机构
[1] Stanford Univ MIPS, Dept Radiol, Stanford, CA 94305 USA
基金
新加坡国家研究基金会;
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We evaluated the timing performance of our data acquisition system (DAQ) with compressed sensing detectors we used in a PET insert for simultaneous PET/MR brain imaging. Compressed sensing is a promising multiplexing method that can achieve high multiplexing ratio while resolving simultaneous hits on multiple pixels without serious degradation of timing and energy resolution for positron emission tomography (PET) scanners. In our compressed sensing detector, each of the 128 silicon photomultiplier (SiPM) pixels produces a unique pattern on the 16 read out channels (the multiplexing ratio is 8: 1), which are digitized and recorded at the DAQ system. The unique decoding pattern for each SiPM is used to recover the crystal indexes. In this study, we used a 10 mu Ci Na-22 radioactive point source to evaluate the coincidence timing resolution across the two lutetium-yttrium orthosilicate (LYSO) based block detectors. We also measured the timing integral non-linearity of the DAQ system by using a pulser to trigger both detectors with the triggering pulses for one detector offset by sequential similar to 2 ns steps. The integral non-linearity of the DAQ system is similar to 0.3 ns across the entire ADC sampling period, which is below the timing resolution for the measurements using a pulser as input (similar to 1.0 ns FWHM). The coincidence timing resolution measured with a 22Na source over the entire 128 crystal block is 5.98 +/- 0.09 ns. Possible factors that are limiting the current timing performance are also presented.
引用
收藏
页数:3
相关论文
共 50 条
  • [41] Design of a data acquisition system for depth-of-interaction detectors
    Lewellen, Tom
    Miyaoka, Robert
    Hauck, Scott
    Otis, Brian
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [42] A prototype of wireless power and data acquisition system for large detectors
    De Lurgio, P.
    Djurcic, Z.
    Drake, G.
    Hashemian, R.
    Kreps, A.
    Oberling, M.
    Pearson, T.
    Sahoo, H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 785 : 99 - 104
  • [43] A Signal-agnostic Compressed Sensing Acquisition System for Wireless and Implantable Sensors
    Chen, Fred
    Chandrakasan, Anantha P.
    Stojanovic, Vladimir
    IEEE CUSTOM INTEGRATED CIRCUITS CONFERENCE 2010, 2010,
  • [44] DESIGN AND IMPLEMENTATION OF A FULLY INTEGRATED COMPRESSED-SENSING SIGNAL ACQUISITION SYSTEM
    Yoo, Juhwan
    Becker, Stephen
    Monge, Manuel
    Loh, Matthew
    Candes, Emmanuel
    Emami-Neyestanak, Azita
    2012 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2012, : 5325 - 5328
  • [45] Compressed sensing for kinetic parameter estimation of sparsely sampled dynamic PET data
    Wong, Koon-Pong
    Huang, Sung-Cheng
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [46] Evaluation of Penalizing Functions in Compressed Sensing to Recover Undersampled Data in PET Imaging
    Valiollahzadeh, S.
    Clark, J.
    Mawlawi, O.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [47] The rrimage pet data acquisition system: initial results
    Sportelli G.
    Ahmad S.
    Belcari N.
    Bisogni M.G.
    Camarlinghi N.
    Di Pasquale A.
    Dussoni S.
    Fleury J.
    Morrocchi M.
    Zaccaro E.
    Del Guerra A.
    1600, Institute of Electrical and Electronics Engineers Inc. (01): : 168 - 177
  • [48] Time over Threshold Data Acquisition System for PET
    Sanchez-Tembleque, V.
    Fraile, L. M.
    Udias, J. M.
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [49] CT acquisition using PET detectors and electronics
    Bérard, P
    Pepin, CM
    Rouleau, D
    Cadorette, J
    Lecomte, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (03) : 634 - 637
  • [50] CT acquisition using PET detectors and electronics
    Bérard, P
    Pepin, CM
    Rouleau, D
    Cadorette, J
    Lecomte, R
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2192 - 2195