Routine follow-up after pacemaker implantation: frequency, pacemaker programming and professionals in charge

被引:21
|
作者
van Eck, Jacob W. M. [1 ]
van Hemel, Norbert M. [2 ]
de Voogt, Willem G. [3 ]
Meeder, Joan G. [4 ]
Spierenburg, Hans A. [5 ]
Crommentuyn, Har [4 ]
Keijzer, Rens [5 ]
Grobbee, Diederick E. [1 ]
Moons, Karel G. M. [1 ]
机构
[1] Univ Med Ctr Utrecht, Julius Ctr Hlth Sci & Primary Care, NL-3584 CJ Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Dept Cardiol, NL-3584 CJ Utrecht, Netherlands
[3] Sint Lucas Andreas Hosp, Dept Cardiol, Amsterdam, Netherlands
[4] VieCuri Med Ctr, Dept Cardiol, Venlo, Netherlands
[5] Vlietland Hosp, Dept Cardiol, Schiedam, Netherlands
来源
EUROPACE | 2008年 / 10卷 / 07期
关键词
pacemaker; follow-up; device monitoring;
D O I
10.1093/europace/eun093
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims To describe current evidence of the frequency, contents, and involved professionals of the routine follow-up visits in patients who have received a pacemaker (PM). Methods and results The multicentre FOLLOWPACE study prospectively collected data during implantation and follow-up of 1526 patients who received a PM for the first time. A total of 4914 follow-up visits were studied. Mean follow-up was 394 days with a mean of 3.2 visits per patient. At all follow-up visits, the battery condition was tested in > 93%, the stimulation threshold in > 91%, and sensing in > 87%. The pacemaker parameters as stimulation and sensing thresholds, lead impedances, and percentages of pacing remained stable over time, but these values did depend on the lead location, lead fixation, and pulse duration. The majority of PM (re-)programming was performed during implantation and/or shortly before hospital discharge (50%). PM re-programming during follow-up was most frequently performed by the PM technician alone (95%). Conclusion Crucial PM parameters are regularly checked. Re-programming of PM parameters declined during the first year after PM implantation. The majority of PM checks were carried out by the PM technician, indicating the major influence of the allied professional on the quality and safety of the pacing therapy.
引用
收藏
页码:832 / 837
页数:6
相关论文
共 50 条
  • [41] Pacemaker follow-up: needs techniques and effectiveness
    Whitlock, R
    VI ASIAN-PACIFIC SYMPOSIUM ON CARDIAC PACING AND ELECTROPHYSIOLOGY, 1997, : 31 - 36
  • [42] BIRTH AFTER IMPLANTATION OF PACEMAKER WITH FIXED FREQUENCY
    SZINNYAI, M
    VARGA, J
    ZENTRALBLATT FUR GYNAKOLOGIE, 1974, 96 (45): : 1417 - 1421
  • [43] NURSE OPERATED PACEMAKER FOLLOW-UP CLINIC
    SCOTT, SM
    MILLER, JA
    MCINNIS, JC
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1979, 2 (05): : A111 - A111
  • [44] Organizing a pacemaker clinic and follow-up programme
    Song, S
    VI ASIAN-PACIFIC SYMPOSIUM ON CARDIAC PACING AND ELECTROPHYSIOLOGY, 1997, : 13 - 16
  • [45] PACEMAKER FOLLOW-UP WITH RESPECT TO ELECTRODE TYPE
    HANSEN, W
    KAFKA, W
    RUDOLPH, W
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1981, 4 (03): : A49 - A49
  • [46] PACECARE - A COMPUTERIZED DATABASE FOR PACEMAKER FOLLOW-UP
    STRATHMORE, N
    MOND, H
    HUNT, D
    GRAHAM, D
    COWLING, R
    HALE, G
    PATE, B
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1990, 13 (12): : 1787 - 1791
  • [47] FOLLOW-UP OF PATIENT WITH AN IMPLANTED CARDIAC PACEMAKER
    ESCHER, DJW
    MODERN CONCEPTS OF CARDIOVASCULAR DISEASE, 1974, 43 (03) : 77 - 80
  • [48] CARDIAC-PACEMAKER TRANSTELEPHONE FOLLOW-UP
    HURZELER, P
    IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1984, 3 (02): : 19 - 23
  • [49] PACEMAKER FOLLOW-UP AND ADEQUACY OF MEDICARE GUIDELINES
    VALLARIO, LE
    LEMAN, RB
    GILLETTE, PC
    KRATZ, JM
    AMERICAN HEART JOURNAL, 1988, 116 (01) : 11 - 15
  • [50] FOLLOW-UP OF A RESPIRATORY RATE MODULATED PACEMAKER
    SANTOMAURO, M
    FAZIO, S
    FERRARO, S
    MADDALENA, G
    PAPACCIOLI, G
    PAPPONE, C
    SACCA, L
    CHIARIELLO, M
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (01): : 17 - 21