Routine follow-up after pacemaker implantation: frequency, pacemaker programming and professionals in charge

被引:21
|
作者
van Eck, Jacob W. M. [1 ]
van Hemel, Norbert M. [2 ]
de Voogt, Willem G. [3 ]
Meeder, Joan G. [4 ]
Spierenburg, Hans A. [5 ]
Crommentuyn, Har [4 ]
Keijzer, Rens [5 ]
Grobbee, Diederick E. [1 ]
Moons, Karel G. M. [1 ]
机构
[1] Univ Med Ctr Utrecht, Julius Ctr Hlth Sci & Primary Care, NL-3584 CJ Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Dept Cardiol, NL-3584 CJ Utrecht, Netherlands
[3] Sint Lucas Andreas Hosp, Dept Cardiol, Amsterdam, Netherlands
[4] VieCuri Med Ctr, Dept Cardiol, Venlo, Netherlands
[5] Vlietland Hosp, Dept Cardiol, Schiedam, Netherlands
来源
EUROPACE | 2008年 / 10卷 / 07期
关键词
pacemaker; follow-up; device monitoring;
D O I
10.1093/europace/eun093
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims To describe current evidence of the frequency, contents, and involved professionals of the routine follow-up visits in patients who have received a pacemaker (PM). Methods and results The multicentre FOLLOWPACE study prospectively collected data during implantation and follow-up of 1526 patients who received a PM for the first time. A total of 4914 follow-up visits were studied. Mean follow-up was 394 days with a mean of 3.2 visits per patient. At all follow-up visits, the battery condition was tested in > 93%, the stimulation threshold in > 91%, and sensing in > 87%. The pacemaker parameters as stimulation and sensing thresholds, lead impedances, and percentages of pacing remained stable over time, but these values did depend on the lead location, lead fixation, and pulse duration. The majority of PM (re-)programming was performed during implantation and/or shortly before hospital discharge (50%). PM re-programming during follow-up was most frequently performed by the PM technician alone (95%). Conclusion Crucial PM parameters are regularly checked. Re-programming of PM parameters declined during the first year after PM implantation. The majority of PM checks were carried out by the PM technician, indicating the major influence of the allied professional on the quality and safety of the pacing therapy.
引用
收藏
页码:832 / 837
页数:6
相关论文
共 50 条
  • [31] Pacemaker dependency at 2-month follow-up after permanent pacemaker implantation caused by transcatheter aortic valve implantation-induced conduction disturbances
    van Mourik, Martijn
    Kooistra, Nynke
    Kooiman, Kirsten
    Vendrik, Jeroen
    Stella, Pieter
    Baan, Jan
    Henriques, Jose P. S.
    Vis, Marije
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (13) : B190 - B191
  • [32] FOLLOW-UP OF PATIENTS UNDERGOING POST-EXTRACTION LEADLESS PACEMAKER IMPLANTATION
    Ferrieri, A.
    Dentico, A.
    Altieri, T.
    Carretta, F.
    Agostino, C. D'
    Carretta, D.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2023, 25
  • [33] FOLLOW-UP FREQUENCY MODULATED BY PACEMAKER PERFORMANCE IN A COMPUTERIZED SURVEILLANCE CENTER
    FLETCHER, RD
    MCMANUS, C
    CREWS, J
    DELNEGRO, AA
    CIRCULATION, 1985, 72 (04) : 174 - 174
  • [34] Clinical application of remote monitoring in post-pacemaker implantation follow-up
    Wang, Rui
    Huang, He
    Liu, Yu
    Kong, Bin
    BIOMEDICAL RESEARCH-INDIA, 2017, 28 (13): : 5733 - 5738
  • [35] Follow-up of patients with permanent pacemaker implantation after transcatheter aortic valve implantation. Is there still need for pacing?
    Reinsch, N.
    Patsalis, P. C.
    Al-Rashid, F.
    Eggebrecht, H.
    Neumann, T.
    Konorza, T.
    Wendt, D.
    Thielmann, M.
    Jakob, H. -G.
    Erbel, R.
    Kahlert, P.
    MEDIZINISCHE KLINIK-INTENSIVMEDIZIN UND NOTFALLMEDIZIN, 2012, 107 (04) : 328 - 329
  • [36] The importance of frequent follow-up in the first year after pacemaker implantation upon detection of atrial tachyarrhythmia
    Nowek, Anna
    Chudzik, Michal
    Wranicz, Jerzy K.
    MEDICAL STUDIES-STUDIA MEDYCZNE, 2016, 32 (03) : 184 - 188
  • [37] PACEMAKER FOLLOW-UP - ITS ROLE IN THE DETECTION AND CORRECTION OF PACEMAKER SYSTEM MALFUNCTION
    GRIFFIN, JC
    SCHUENEMEYER, TD
    HESS, KR
    GLAESER, D
    ANDERSON, BJ
    ROMANS, E
    JENKINS, MA
    NIELSEN, AP
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1986, 9 (03): : 387 - 391
  • [38] TIMING MARKERS SHOWING PACEMAKER BEHAVIOR TO AID IN THE FOLLOW-UP OF A PHYSIOLOGICAL PACEMAKER
    KRUSE, IB
    MARKOWITZ, T
    RYDEN, L
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1983, 6 (04): : 801 - 805
  • [39] ELEMENTS OF ELECTROCARDIOGRAPHIC FOLLOW-UP FOR AN IMPLANTED PACEMAKER
    VALERE, PE
    TRICOT, R
    LAFFAY, N
    COEUR ET MEDECINE INTERNE, 1972, 11 (02): : 309 - &
  • [40] THE CLINICAL UTILITY OF PACEMAKER FOLLOW-UP VISITS
    MUGICA, J
    HENRY, L
    ROLLET, M
    PODEUR, H
    HAQUIN, G
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1986, 9 (06): : 1249 - 1252