Routine follow-up after pacemaker implantation: frequency, pacemaker programming and professionals in charge

被引:21
|
作者
van Eck, Jacob W. M. [1 ]
van Hemel, Norbert M. [2 ]
de Voogt, Willem G. [3 ]
Meeder, Joan G. [4 ]
Spierenburg, Hans A. [5 ]
Crommentuyn, Har [4 ]
Keijzer, Rens [5 ]
Grobbee, Diederick E. [1 ]
Moons, Karel G. M. [1 ]
机构
[1] Univ Med Ctr Utrecht, Julius Ctr Hlth Sci & Primary Care, NL-3584 CJ Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Dept Cardiol, NL-3584 CJ Utrecht, Netherlands
[3] Sint Lucas Andreas Hosp, Dept Cardiol, Amsterdam, Netherlands
[4] VieCuri Med Ctr, Dept Cardiol, Venlo, Netherlands
[5] Vlietland Hosp, Dept Cardiol, Schiedam, Netherlands
来源
EUROPACE | 2008年 / 10卷 / 07期
关键词
pacemaker; follow-up; device monitoring;
D O I
10.1093/europace/eun093
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims To describe current evidence of the frequency, contents, and involved professionals of the routine follow-up visits in patients who have received a pacemaker (PM). Methods and results The multicentre FOLLOWPACE study prospectively collected data during implantation and follow-up of 1526 patients who received a PM for the first time. A total of 4914 follow-up visits were studied. Mean follow-up was 394 days with a mean of 3.2 visits per patient. At all follow-up visits, the battery condition was tested in > 93%, the stimulation threshold in > 91%, and sensing in > 87%. The pacemaker parameters as stimulation and sensing thresholds, lead impedances, and percentages of pacing remained stable over time, but these values did depend on the lead location, lead fixation, and pulse duration. The majority of PM (re-)programming was performed during implantation and/or shortly before hospital discharge (50%). PM re-programming during follow-up was most frequently performed by the PM technician alone (95%). Conclusion Crucial PM parameters are regularly checked. Re-programming of PM parameters declined during the first year after PM implantation. The majority of PM checks were carried out by the PM technician, indicating the major influence of the allied professional on the quality and safety of the pacing therapy.
引用
收藏
页码:832 / 837
页数:6
相关论文
共 50 条
  • [1] HYPERSENSITIVITY OF THE CAROTIS SINUS - FOLLOW-UP AFTER PACEMAKER-IMPLANTATION
    WALDECKER, B
    BRACHMANN, J
    FREES, U
    THORSPECKEN, R
    KUBLER, W
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1986, 9 (02): : 293 - 293
  • [2] Pacemaker follow-up after device replacement
    Ucar, F. M.
    HERZ, 2019, 44 (01) : 82 - 82
  • [3] Results of follow-up of patients with sick sinus syndrome after implantation of a pacemaker
    Iskenderov, BG
    Latyshev, DS
    TERAPEVTICHESKII ARKHIV, 2000, 72 (11) : 54 - 56
  • [4] Long-term follow-up after pacemaker implantation in neonates and infants
    Aellig, Natalie C.
    Balmer, Christian
    Dodge-Khatami, Ali
    Rahn, Mariette
    Pretre, Rene
    Bauersfeld, Urs
    ANNALS OF THORACIC SURGERY, 2007, 83 (04): : 1420 - 1424
  • [5] Long-term follow-up after pacemaker implantation in neonates and infants
    Chen, Peng-Sheng
    HEART RHYTHM, 2007, 4 (07) : 987 - 987
  • [6] Permanent Pacemaker Implantation Early After Cardiac Surgery: A Descriptive Study of Pacemaker Utility After One Year of Follow-Up
    Patel, Ajay M.
    Verma, Dhruv
    Jiang, Sheng-Fang
    Lau, Kimberly Y.
    Arrellano, Jerry L.
    Cain, Brian S.
    Zaroff, Jonathan G.
    JOURNAL OF CARDIAC SURGERY, 2016, 31 (03) : 132 - 138
  • [7] UTILITY OF RATE HISTOGRAMS IN PROGRAMMING AND FOLLOW-UP OF A DDDR PACEMAKER
    HAYES, DL
    HIGANO, ST
    EISINGER, G
    MAYO CLINIC PROCEEDINGS, 1989, 64 (05) : 495 - 502
  • [8] FOLLOW-UP OF PACEMAKER DEVICES
    MARKEWITZ, A
    HEMMER, W
    BERNHEIM, C
    KEMKES, BM
    HERZ KREISLAUF, 1985, 17 (11): : 598 - 604
  • [9] Contralateral pneumothorax in the subacute phase after pacemaker implantation: lead retention and follow-up
    Chen, Xiao-Dong
    Xu, Xu
    Ji, Jia-Wen
    Liu, Hai-Lei
    Shen, Jian-Ping
    JOURNAL OF GERIATRIC CARDIOLOGY, 2018, 15 (12) : 744 - 746
  • [10] Procedural safety and long-term follow-up after pacemaker implantation in nonagenarians
    Loirat, A.
    Feneon, D.
    Behaghel, A.
    Behar, N.
    Le Helloco, A.
    Mabo, P.
    Daubert, J. C.
    Leclercq, C.
    Martins, R. P.
    EUROPEAN HEART JOURNAL, 2015, 36 : 398 - 399