Management of multiple brain metastases via dual-isocenter VMAT stereotactic radiosurgery

被引:4
|
作者
Palmiero, Allison N. [1 ]
Fabian, Denise [1 ]
St Clair, William [1 ]
Randall, Marcus [1 ]
Pokhrel, Damodar [1 ]
机构
[1] Univ Kentucky, Dept Radiat Med, Med Phys Grad Program, 800 Rose St, Lexington, KY 40536 USA
关键词
Dual-isocenter; VMAT-SRS; Set up uncertainties; Multiple brain metastases; Dose bridging and brain toxicity; SINGLE-ISOCENTER; FRAMELESS; TARGETS;
D O I
10.1016/j.meddos.2021.01.002
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Single-isocenter volumetric modulated arc therapy (VMAT) stereotactic radiosurgery (SRS) techniques to treat multiple brain metastases simultaneously can significantly improve treatment delivery efficiency, patient compliance, and clinic workflow. However, due to large number of brain metastases sharing the same MLC pair causing island blocking, there is higher low-and intermediate-dose spillage to the normal brain and higher dose to organs-at-risk (OAR). To minimize this problem and improve plan quality, this study proposes a dual-isocenter planning strategy that groups lesions based on hemisphere location (left vs right sided) in the brain parenchyma, providing less island blocking reducing the MLC travel distance. This technique offers simplified planning while also increasing patient comfort and compliance by allowing for large number of brain metastases to be treated in 2 groups. Seven complex patients with 5 to 16 metastases (64 total) were planned with a single-isocenter VMAT-SRS technique using a 10MV-FFF beam with a prescription of 20 Gy to each lesion. The isocenter was placed at the approximate geometric center of the targets. Each patient was replanned using the dual-isocenter approach, generating 2 plans and placing each isocenter at the approximate geometric center of the combined targets of each side with corresponding non-coplanar partial arcs. Compared to single-isocenter VMAT, dual-isocenter VMAT plans provided similar target coverage and dose conformity with less spread of intermediate dose to normal brain with reduction of dose to OAR. Reduction in total monitor units and beam on time was observed, but due to the second isocenter setup and verification, overall treatment time was increased. Dual-isocenter VMAT-SRS planning for multiple brain metastases is a simplified approach that provides superior treatment options for patient compliance who may not tolerate longer traditional treatment times as with individual isocenters to each target. This planning technique significantly reduces the amount of low-and intermediate-dose spillage, further sparing OAR and normal brain, potentially improving target accuracy though localization of left vs right-sided tumors for each isocenter set up. (c) 2021 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:240 / 246
页数:7
相关论文
共 50 条
  • [21] Stereotactic Radiosurgery for the Management of Brain Metastases
    Suh, John H.
    NEW ENGLAND JOURNAL OF MEDICINE, 2010, 362 (12): : 1119 - 1127
  • [22] Stereotactic Radiosurgery for the Management of Brain Metastases
    Rockoff, Mark A.
    NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (06): : 592 - 592
  • [23] Dosimetric verification of single isocenter VMAT for multiple brain metastases
    Decabooter, E.
    Swinnen, A.
    Canters, R.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S935 - S936
  • [24] Radiosurgery of Multiple Brain Metastases with Single-Isocenter VMAT: Optimizing Treatment Geometry to Reduce Normal Brain Dose
    Wu, Q.
    Snyder, K.
    Liu, C.
    Huang, Y.
    Li, H.
    Chetty, I.
    Wen, N.
    MEDICAL PHYSICS, 2015, 42 (06) : 3576 - 3576
  • [25] Heuristic knowledge-based planning for single-isocenter stereotactic radiosurgery to multiple brain metastases
    Ziemer, Benjamin P.
    Sanghvi, Parag
    Hattangadi-Gluth, Jona
    Moore, Kevin L.
    MEDICAL PHYSICS, 2017, 44 (10) : 5001 - 5009
  • [26] Problem of Single Isocenter Radiosurgery for Patients with multiple Brain Metastases
    Izaguirre, V
    Sieker, F.
    Kornhuber, C.
    Vordermark, D.
    Gerlach, R.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 : 76 - 77
  • [27] Dosimetric Impact of Setup Errors in Single-Isocenter VMAT Radiosurgery for Brain Metastases
    Faccenda, V.
    Panizza, D.
    Trivellato, S.
    Daniotti, M. C.
    Pisoni, V.
    Lucchini, R.
    Arcangeli, S.
    De Ponti, E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : E102 - E103
  • [28] Dosimetric impact of setup errors in single-isocenter VMAT radiosurgery for brain metastases
    Panizza, D.
    Faccenda, V.
    Trivellato, S.
    Caricato, P.
    Pisoni, V.
    Lucchini, R.
    De Ponti, E.
    Arcangeli, S.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S253 - S253
  • [29] Stereotactic radiotherapy with single-isocenter in multiple brain metastases
    Matteucci, P.
    Silipigni, S.
    Rinaldi, C. G.
    Ridolfi, I.
    Falco, P.
    Fiore, M.
    Ippolito, E.
    Ramella, S.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S866 - S867
  • [30] Single isocenter treatment planning techniques for stereotactic radiosurgery of multiple cranial metastases
    Velten, Christian
    Kabarriti, Rafi
    Garg, Madhur
    Tome, Wolfgang A.
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2021, 17 : 47 - 52