A time-based flow injection cold vapor atomic absorption spectrometry system with on-line microwave sample pre-treatment for the determination of inorganic and total mercury in urine

被引:55
|
作者
Gallignani, M [1 ]
Bahsas, H [1 ]
Brunetto, MR [1 ]
Burguera, M [1 ]
Burguera, JL [1 ]
de Peña, YP [1 ]
机构
[1] Univ Los Andes, IVAIQUIM Venezuelan Andean Inst Chem Res, Fac Sci, Merida 5101A, Venezuela
关键词
urine; mercury; on-line microwave digestion; flow injection;
D O I
10.1016/S0003-2670(98)00217-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A time based injection system used in conjunction with cold vapor generation atomic absorption spectrometry and microwave-aided heating oxidation with potassium persulfate has been developed for the determination of total and inorganic mercury in urine samples. Inorganic mercury is determined after reduction with SnCl2 while total mercury is determined after an on-line oxidation step with persulfate prior to the reduction step to elemental mercury with SnCl2. The difference between total and inorganic mercury determines the organomercury content in samples. Experimental parameters were optimized by the univariate optimization method. A linear calibration graph was obtained in the range 0.2-20 mu g l(-1) of Hg2+ by using injection times from 0 to 12 s of a solution of 20 mu g l(-1) of either inorganic or organic mercury. The detection limit based on 3 sigma of the blank signal was 0.1 mu g Hg l(-1) regardless of the mercury species under evaluation. The relative standard deviations for five independent measurements were 1.5% and 1.0% for total and inorganic mercury. The recoveries of different amounts of inorganic and organic mercury added to urine samples ranged from 98.5% to 102.2% and from 97.0% to 103%, respectively. Good agreement with certified values of the total mercury containing urine reference materials were also obtained. With the proposed procedure, 20 urine samples of unexposed subjects from Merida city were measured; and the values lay in the range between 1.8 and 6.7 mu g l(-1). In addition, the use of a mercury standard solution as the carrier converts the flow injection manifold used in this work to an on-line standard addition system which permits a rapid and simple test for monitoring the mercury levels in these samples. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:57 / 67
页数:11
相关论文
共 50 条
  • [41] Determination of mercury in fish by cold vapor atomic absorption spectrophotometry using a multicommuted flow injection analysis system
    Silva, M. Fatima
    Toth, Ildiko V.
    Rangel, Antonio O. S. S.
    ANALYTICAL SCIENCES, 2006, 22 (06) : 861 - 864
  • [42] Determination of Mercury in Fish by Cold Vapor Atomic Absorption Spectrophotometry Using a Multicommuted Flow Injection Analysis System
    M. Fátima Silva
    Ildikó V. Tóth
    António O. S. S. Rangel
    Analytical Sciences, 2006, 22 : 861 - 864
  • [43] On-line focused microwave digestion hydride generation of inorganic and organic selenium: Total determination and inorganic selenium speciation by atomic absorption spectrometry
    LaFuente, JMG
    Sanchez, MLF
    MarchanteGayon, JM
    Uria, JES
    SanzMedel, A
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1996, 51 (14) : 1849 - 1857
  • [44] COMPARISON OF OPEN AND CLOSED FOCUSED MICROWAVE DIGESTIONS IN VIEW OF TOTAL MERCURY DETERMINATION BY COLD VAPOR ATOMIC-ABSORPTION SPECTROMETRY
    SCHNITZER, G
    SOUBELET, A
    TESTU, C
    CHAFEY, C
    MIKROCHIMICA ACTA, 1995, 119 (3-4) : 199 - 209
  • [45] Determination of As(III) and total inorganic As in water samples using an on-line solid phase extraction and flow injection hydride generation atomic absorption spectrometry
    Sigrist, Mirna
    Albertengo, Antonela
    Beldomenico, Horacio
    Tudino, Mabel
    JOURNAL OF HAZARDOUS MATERIALS, 2011, 188 (1-3) : 311 - 318
  • [46] Determination of mercury in cosmetics by flow injection-cold vapour generation-atomic fluorescence spectrometry with on-line preconcentration
    Gámiz-Gracia, L
    de Castro, MDL
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (10) : 1615 - 1617
  • [47] An automated on-line flow system for the pre-concentration and determination of lead by flame atomic absorption spectrometry
    Ferreira, SLC
    Lemos, VA
    Santelli, RE
    Ganzarolli, E
    Curtius, AJ
    MICROCHEMICAL JOURNAL, 2001, 68 (01) : 41 - 46
  • [48] Flow injection-liquid chromatography-cold vapour atomic absorption spectrometry for rapid determination of methyl and inorganic mercury
    Qvarnström, J
    Tu, Q
    Frech, W
    Lüdke, C
    ANALYST, 2000, 125 (06) : 1193 - 1197
  • [49] Determination of mercury in size fractionated road dust samples by flow injection-cold vapor-atomic absorption spectrometry
    Londonio, Agustin
    Fujiwara, Fabian
    Jimenez Rebagliati, Raul
    Gomez, Dario
    Smichowski, Patricia
    MICROCHEMICAL JOURNAL, 2012, 105 : 77 - 82
  • [50] INTERFERENCE BY VOLATILE NITROGEN-OXIDES IN THE DETERMINATION OF MERCURY BY FLOW-INJECTION COLD VAPOR ATOMIC-ABSORPTION SPECTROMETRY
    ROKKJAER, I
    HOYER, B
    JENSEN, N
    TALANTA, 1993, 40 (05) : 729 - 735