A New DSTATCOM Topology Using Hybrid Renewable Energy Based DC-Link VSI for Power Quality Applications

被引:0
|
作者
Gawande, S. P. [1 ]
Debre, P. D. [2 ]
Ramteke, M. R. [3 ]
机构
[1] Yeshwantrao Chavan Coll Engn, Dept Elect Engn, Nagpur, Maharashtra, India
[2] Rajiv Gandhi Coll Engn & Res, Dept Elect Engn, Nagpur, Maharashtra, India
[3] Visvesvaraya Natl Inst Technol, Dept Elect Engn, Nagpur, Maharashtra, India
关键词
DSTATCOM; photovoltaic array; MPPT perturb and observe; power quality; wind turbine; GENERATORS;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this paper, Distribution Static Compensator (DSTATCOM) is proposed for load compensation using photovoltaic (PV) array and Permanent Magnet Synchronous Generator (PMSG) based wind turbine for dc generation; forming hybrid renewable energy sources based dc-link voltage source inverter (VSI). PV is installed along with Perturb and Observe (P & O) maximum power point tracking (MPPT) method applied to dc-dc boost converter, in desire to generate the required dc voltage for one of the split dc capacitor. For the lower dc-link capacitor, required dc voltage is generated using PMSG based wind energy system which extracts maximum power from wind through switch mode rectifier, using simplified output maximization control. The effective combination of PV and wind along with their MPPT controls, eliminate the need of battery, pre-charge capacitor circuitry and dc-link voltage regulation control. It is observed that the DSTATCOM operates effectively providing balanced and sinusoidal source currents with unity power factor (UPF), in the presence of unbalanced and non-linear load. The reference currents for shunt controller are extracted using instantaneous symmetrical component theory (ISCT), however, the switching sequence for VSI is generated using hysteresis current control technique. The proposed scheme is found to be advantageous in terms of providing uninterruptable reparations. The effective system performance is demonstrated and validated through extensive digital simulations using MATLAB environment.
引用
收藏
页码:2880 / 2885
页数:6
相关论文
共 50 条
  • [41] Power Quality Improvement of a Hybrid Renewable Energy Sources Based Standalone System Using Neuro-Fuzzy Controllers
    Deepak K.
    Kumar Mandal R.
    Verma V.
    Distributed Generation and Alternative Energy Journal, 2023, 38 (06): : 1815 - 1838
  • [42] Double power MOSFETs high-gain DC–DC topology using two-winding coupled inductor for renewable energy usage
    Abbasian, Sohrab
    Zakerian, Ali
    Farsijani, Mohammad
    Nikbakht, Masoud
    Roinila, Tomi
    IET Power Electronics, 2024, 17 (16) : 2785 - 2795
  • [43] A simple fuzzy logic based DC link energy management system for hybrid industrial power supply
    Mbende, Ernest Titi
    Muluh, Fombu Andrew
    Pesdjock, Mathieu Jean Pierre
    Kenne, Godpromesse
    Dagang, Clotaire Thierry Sanjong
    Sonfack, Lionel Leroy
    ENERGY REPORTS, 2023, 10 : 3619 - 3628
  • [44] Energy Management and Power Quality Improvement of Hybrid Renewable Energy Generation System Using Coordinated Control Scheme
    Kanagaraj, N.
    Vijayakumar, M.
    Ramasamy, M.
    Aldosari, Obaid
    IEEE ACCESS, 2023, 11 : 93254 - 93267
  • [45] An Improved Interleaved DC-DC SEPIC Converter Based on SiC-Cascode Power Devices for Renewable Energy Applications
    Alharbi, Salah S.
    Alharbi, Saleh S.
    Matin, Mohammad
    2018 IEEE INTERNATIONAL CONFERENCE ON ELECTRO/INFORMATION TECHNOLOGY (EIT), 2018, : 487 - 492
  • [46] Electrical machines based DC/AC energy conversion schemes for the improvement of power quality and resiliency in renewable energy microgrids
    Kumar, Y. V. Pavan
    Bhimasingu, Ravikumar
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2017, 90 : 10 - 26
  • [47] Analysis of DC-Link Operation Voltage of a Hybrid Railway Power Quality Conditioner and Its PQ Compensation Capability in High-Speed Cophase Traction Power Supply
    Lao, Keng-Weng
    Wong, Man-Chung
    Dai, Ning Yi
    Wong, Chi-Kong
    Lam, Chi-Seng
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2016, 31 (02) : 1643 - 1656
  • [48] Reduction of DC-link Current Harmonics over Wide Power-Factor Range for Three-Phase VSI using Single-Carrier-Comparison Continuous PWM
    Nishizawa, Koroku
    Itoh, Jun-ichi
    Fujita, Satoru
    Odaka, Akihiro
    Toba, Akio
    Umida, Hidetoshi
    2018 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2018, : 6772 - 6779
  • [49] Power Quality Enhancement of Grid-Tied 7L-PUC Inverter-Based PV System Using a Novel DC-Link Controller
    Abdelouahad May
    Fateh Krim
    Hamza Feroura
    Abdesslam Belaout
    Arabian Journal for Science and Engineering, 2023, 48 : 15305 - 15319
  • [50] Power Quality Enhancement of Grid-Tied 7L-PUC Inverter-Based PV System Using a Novel DC-Link Controller
    May, Abdelouahad
    Krim, Fateh
    Feroura, Hamza
    Belaout, Abdesslam
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2023, 48 (11) : 15305 - 15319