Impact of a time-to-effect-guided ablation protocol in cryoballoon ablation on the durability of pulmonary vein isolation

被引:3
|
作者
Rexha, Enida [1 ]
Heeger, Christian-Hendrik [2 ]
Maack, Sabrina [1 ]
Rottner, Laura [3 ]
Wohlmuth, Peter [1 ]
Lemes, Christine [2 ]
Maurer, Tilman [1 ]
Reissmann, Bruno [3 ]
Rillig, Andreas [3 ]
Mathew, Shibu [4 ]
Sohns, Christian [5 ]
Ouyang, Feifan [3 ]
Kuck, Karl-Heinz [2 ]
Metzner, Andreas [3 ]
机构
[1] Asklepios Klin St Georg, Dept Cardiol, Lohmuhlenstr 5, D-20099 Hamburg, Germany
[2] Univ Hosp Schleswig Holstein, Univ Heart Ctr Lubeck, Dept Cardiol Angiol & Intens Care Med, Med Clin 2, Lubeck, Germany
[3] Univ Heart Ctr Hamburg, Dept Cardiol, Hamburg, Germany
[4] Univ Clin Giessen, Dept Cardiol, Giessen, Germany
[5] Ruhr Univ Bochum, Herz & Diabeteszentrum NRW, Clin Electrophysiol, Bad Oeynhausen, Germany
关键词
atrial fibrillation; cryoballoon ablation; pulmonary vein reconduction rate; recurrence of atrial tachyarrhythmia; time to isolation; 2ND-GENERATION CRYOBALLOON; RADIOFREQUENCY ABLATION; ATRIAL-FIBRILLATION; ESOPHAGEAL LESIONS; BONUS-FREEZE;
D O I
10.1111/jce.15453
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Cryoballoon (CB)-based pulmonary vein isolation (PVI) has proven to be as effective as radiofrequency-based ablation. Different ablation protocols took the individual time-to-isolation (TTI) into account aiming at shorter but equally or even more effective freeze cycles. The current study sought to assess the impact of the TTI on PVI durability in patients undergoing a repeat procedure for recurrence of atrial tachyarrhythmia (ATA). Methods and Results In 205 patients with ATA recurrence after previous CB-based PVI, a total of 806 pulmonary veins (PVs) were identified. A total of 126 out of 806 PVs (16%) were previously treated with a TTI-guided ablation (Protocol #1; TTI + 120 s), in 92/806 (11%) PVs TTI was only monitored (m) but fixed freeze cycles were applied (Protocol #2; mTTI) and in 588/806 (73%) a fixed freeze cycle was applied without mTTI. There was no difference in the PV-reconduction rate between the groups (p = .23). The right inferior pulmonary vein (RIPV) showed overall significantly higher reconduction rates compared to the other PVs (RIPV-left inferior PV p < .003, -left superior PV p < .001, -right superior PV p < .013). Twenty-one patients (10%) were demonstrated to have only electrical reconduction of the RIPV, while all other PVs were still electrically isolated. Conclusions The TTI-based CB ablation protocol did not show significant differences regarding PV-reconduction rates compared to the other ablation protocols.
引用
收藏
页码:1096 / 1103
页数:8
相关论文
共 50 条
  • [21] CHARACTERIZATION OF ATRIAL FLUTTER AFTER PULMONARY VEIN ISOLATION BY CRYOBALLOON ABLATION
    Baman, Jayson
    Kaplan, Rachel
    Diaz, Celso
    Peigh, Graham
    Bavishi, Aakash
    Trivedi, Amar
    Shen, Mark
    Sattayaprasert, Prasongchai
    Wasserlauf, Jeremiah
    Chicos, Alexandru
    Arora, Rishi
    Kim, Susan
    Lin, Albert
    Verma, Nishant
    Knight, Bradley
    Passman, Rod
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 327 - 327
  • [22] Cryoballoon ablation for pulmonary vein isolation in patients with paroxysmal atrial fibrillation
    Kuehne, Michael
    Schaer, Beat
    Ammann, Peter
    Suter, Yves
    Osswald, Stefan
    Sticherling, Christian
    SWISS MEDICAL WEEKLY, 2010, 140 (15-16) : 214 - 221
  • [23] Impact of atrial rhythm on pulmonary vein signals in cryoballoon ablation - Sinus rhythm predicts real-time observation of pulmonary vein isolation
    Pott, Alexander
    Baumhardt, Michael
    Weinmann, Karolina
    Rattka, Manuel
    Stephan, Tilman
    Kessler, Mirjam
    Bothner, Carlo
    Petscher, Kerstin
    Rottbauer, Wolfgang
    Dahme, Tillman
    IJC HEART & VASCULATURE, 2019, 23
  • [24] Comparison of advanced generation cryoballoon ablation and ablation index-guided pulmonary vein isolation with non-pulmonary vein trigger induction test and additional ablation in paroxysmal atrial fibrillation
    Egami, Yasuyuki
    Nishino, Masami
    Nohara, Hiroaki
    Kawanami, Shodai
    Sugae, Hiroki
    Ukita, Kohei
    Kawamura, Akito
    Nakamura, Hitoshi
    Yasumoto, Koji
    Tsuda, Masaki
    Okamoto, Naotaka
    Matsunaga-Lee, Yasuharu
    Yano, Masamichi
    Tanouchi, Jun
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2023, 66 (07) : 1571 - 1580
  • [25] Effect of Myocardial Injury and Inflammation on Recurrence After Pulmonary Vein Isolation is Differentbetween Radiofrequency Catheter Ablation and Cryoballoon Ablation
    Yano, Masamichi
    Nishino, Masami
    Nohara, Hiroaki
    Toyoshima, Taku
    Higashino, Naoko
    Ukita, Kohei
    Kawamura, Akito
    Yanagawa, Kyosuke
    Nakamura, Hitoshi
    Matsuhiro, Yutaka
    Yasumoto, Koji
    Okamoto, Naotaka
    Tanaka, Akihiro
    Nakamura, Daisuke
    Matsunaga, Yasuharu
    Yamato, Masaki
    Egami, Yasuyuki
    Shutta, Ryu
    Tanouchi, Jun
    CIRCULATION, 2019, 140
  • [26] Comparison of touch-up ablation rate and pulmonary vein isolation durability between hot balloon and cryoballoon
    Hojo, Rintaro
    Fukamizu, Seiji
    Tokioka, Sayuri
    Inagaki, Dai
    Miyazawa, Satoshi
    Kawamura, Iwanari
    Kitamura, Takeshi
    Sakurada, Harumizu
    Hiraoka, Masayasu
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (06) : 1298 - 1306
  • [27] Comparison of advanced generation cryoballoon ablation and ablation index-guided pulmonary vein isolation with non-pulmonary vein trigger induction test and additional ablation in paroxysmal atrial fibrillation
    Yasuyuki Egami
    Masami Nishino
    Hiroaki Nohara
    Shodai Kawanami
    Hiroki Sugae
    Kohei Ukita
    Akito Kawamura
    Hitoshi Nakamura
    Koji Yasumoto
    Masaki Tsuda
    Naotaka Okamoto
    Yasuharu Matsunaga-Lee
    Masamichi Yano
    Jun Tanouchi
    Journal of Interventional Cardiac Electrophysiology, 2023, 66 : 1571 - 1580
  • [28] Durability of pulmonary vein isolation by various kind of ablation catheter
    Kobori, A.
    Sasaki, Y.
    Matsumoto, Y.
    Ishizu, K.
    Nakashima, M.
    Ishibashi, K.
    Murai, R.
    Oota, M.
    Kim, K.
    Yamane, T.
    Ehara, N.
    Kinoshita, M.
    Kaji, S.
    Furukawa, Y.
    EUROPEAN HEART JOURNAL, 2016, 37 : 632 - 632
  • [29] Durability of Pulmonary Vein Isolation with Cryoballoon Ablation: Results from the Sustained PV Isolation with Arctic Front Advance (SUPIR) Study
    Reddy, Vivek Y.
    Sediva, Lucie
    Petru, Jan
    Skoda, Jan
    Chovanec, Milan
    Chitovova, Zita
    Di Stefano, Paola
    Rubin, Ethel
    Dukkipati, Srinivas
    Neuzil, Petr
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2015, 26 (05) : 493 - 500
  • [30] Bailout cryoballoon ablation after failed pulmonary vein isolation with radiofrequency ablation: Acute success and safety
    Contractor, Tahmeed
    Bhardwaj, Rahul
    Mandapati, Ravi
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (09) : 1751 - 1751