Comparison of touch-up ablation rate and pulmonary vein isolation durability between hot balloon and cryoballoon

被引:11
|
作者
Hojo, Rintaro [1 ]
Fukamizu, Seiji [1 ]
Tokioka, Sayuri [1 ]
Inagaki, Dai [1 ]
Miyazawa, Satoshi [1 ]
Kawamura, Iwanari [1 ]
Kitamura, Takeshi [1 ]
Sakurada, Harumizu [2 ]
Hiraoka, Masayasu [3 ]
机构
[1] Tokyo Metropolitan Hiroo Gen Hosp, Dept Cardiol, Tokyo, Japan
[2] Ohkubo Hosp, Tokyo Metropolitan Hlth & Med Treatment Corp, Tokyo, Japan
[3] Tokyo Med & Dent Univ, Tokyo, Japan
关键词
cryoballoon ablation; hot balloon ablation; paroxysmal atrial fibrillation; pulmonary vein isolation; touch-up ablation; 2ND-GENERATION CRYOBALLOON; CATHETER;
D O I
10.1111/jce.14485
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction This study aimed to compare touch-up ablation (TUA) rates and pulmonary vein isolation (PVI) durability of hot balloon ablation (HBA) and cryoballoon ablation (CBA) in paroxysmal atrial fibrillation (PAF) patients. Methods In total, 137 PAF patients were enrolled in the study. Among them, 59 underwent two HBA procedures at 6-month intervals and 78 patients underwent two CBA sessions, both regardless of atrial fibrillation recurrence. Propensity score matching was performed to estimate similar patient characteristics between the HBA and CBA groups. Results Each group comprised of 46 matched patients for comparison. The TUA rate at the first session was higher for HBA (49 of 184 PVs) than for CBA (20 PVs) (P = .01), with the highest incidence at the left superior pulmonary vein (LSPV). The rates of PVI durability at the second session performed 7 months later were similar between HBA (168 of 184 PVs) and CBA (162 PVs) groups. The PVI durability rate at the TUA sites of the first session was higher for HBA than for CBA (41 of 49 PVs vs 10 PVs, respectively; P = .01). Fifty percent of the patients underwent HBA at 73 degrees C for the LSPV. HBA performed at 73 degrees C yielded a lower TUA rate than that at 70 degrees C (16 of 23 PVs vs 7 of 23 PVs; P = .008). Conclusions While PVI durability was similar between HBA and CBA, the TUA rate was higher for HBA than for CBA, especially on the LSPV. For LSPV, HBA at a balloon temperature of 73 degrees C may reduce the TUA rate.
引用
收藏
页码:1298 / 1306
页数:9
相关论文
共 50 条
  • [1] Electrophysiologic and anatomic factors predictive of a need for touch-up radiofrequency application for complete pulmonary vein isolation: Comparison between hot balloon- and cryoballoon-based ablation
    Wakamatsu, Yuji
    Nagashima, Koichi
    Nakahara, Shiro
    Iso, Kazuki
    Watanabe, Ryuta
    Arai, Masaru
    Otsuka, Naoto
    Yagyu, Seina
    Kurokawa, Sayaka
    Ohkubo, Kimie
    Nakai, Toshiko
    Okumura, Yasuo
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (08) : 1261 - 1269
  • [2] Comparison of pulsed field ablation and cryoballoon ablation for pulmonary vein isolation
    Schipper, Jan-Hendrik
    Steven, Daniel
    Lueker, Jakob
    Woermann, Jonas
    van den Bruck, Jan-Hendrik
    Filipovic, Karlo
    Dittrich, Sebastian
    Scheurlen, Cornelia
    Erlhoefer, Susanne
    Pavel, Friederike
    Sultan, Arian
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (10) : 2019 - 2026
  • [3] Cryoballoon ablation for pulmonary vein isolation
    Andrade, Jason G.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (08) : 2128 - 2135
  • [4] A PRACTICAL MODEL OF BALLOON/TISSUE CONTACT IN PULMONARY VEIN ISOLATION WITH CRYOBALLOON ABLATION
    Smith, David J.
    Murthy, Sam
    Liao, Yu
    PROCEEDINGS OF THE 2024 DESIGN OF MEDICAL DEVICES CONFERENCE, DMD2024, 2024,
  • [5] Time to isolation guided hot balloon ablation for pulmonary vein isolation
    Chikata, A.
    Kato, T.
    Usuda, K.
    Fujita, S.
    Maruyama, M.
    Otowa, K.
    Takashima, S.
    Murai, H.
    Usui, S.
    Furusho, H.
    Kaneko, S.
    Takamura, M.
    EUROPEAN HEART JOURNAL, 2019, 40 : 1793 - 1793
  • [6] Impact of a time-to-effect-guided ablation protocol in cryoballoon ablation on the durability of pulmonary vein isolation
    Rexha, Enida
    Heeger, Christian-Hendrik
    Maack, Sabrina
    Rottner, Laura
    Wohlmuth, Peter
    Lemes, Christine
    Maurer, Tilman
    Reissmann, Bruno
    Rillig, Andreas
    Mathew, Shibu
    Sohns, Christian
    Ouyang, Feifan
    Kuck, Karl-Heinz
    Metzner, Andreas
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (06) : 1096 - 1103
  • [7] Pericardial effusion in atrial fibrillation ablation: a comparison between cryoballoon and radiofrequency pulmonary vein isolation
    Chierchia, Gian Battista
    Capulzini, Lucio
    Droogmans, Steven
    Sorgente, Antonio
    Sarkozy, Andrea
    Muller-Burri, Andreas
    Paparella, Gaetano
    Carlo, de Asmundis
    Yazaki, Yoshinao
    Kerkhove, Dirk
    Van Camp, Guy
    Brugada, Pedro
    EUROPACE, 2010, 12 (03): : 337 - 341
  • [8] Pulmonary Vein Isolation in Atrial Fibrillation: A Comparison between Cryoballoon- and Radiofrequency- Ablation
    Stuehlinger, M.
    Kinz, V.
    Kirchmeyr, F.
    Suessenbacher, A.
    Pachinger, O.
    Hintringer, F.
    WIENER KLINISCHE WOCHENSCHRIFT, 2013, 125 : S82 - S82
  • [9] Efficacy of pulmonary vein isolation with a novel hot balloon ablation catheter
    Evonich, Rudolph F.
    Nori, David M.
    Haines, David E.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2012, 34 (01) : 29 - 36
  • [10] Efficacy of pulmonary vein isolation with a novel hot balloon ablation catheter
    Rudolph F. Evonich
    David M. Nori
    David E. Haines
    Journal of Interventional Cardiac Electrophysiology, 2012, 34 : 29 - 36