Restoration of PSD from chord length distribution data using the method of projections onto convex sets

被引:71
|
作者
Worlitschek, J
Hocker, T
Mazzotti, M
机构
[1] Mettler Toledo GmbH, Autochem, CH-8603 Schwerzenbach, Switzerland
[2] Zuricher Hsch Winterthur, Ctr Computat Phys, CH-8401 Winterthur, Switzerland
关键词
chord length distribution (CLD); focused beam reflectance measurement (FBRM); ill-posed problem; particle size distribution (PSD); projections onto convex sets (POCS);
D O I
10.1002/ppsc.200400872
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The interpretation of chord length distributions (CLDs) is essential in many fields and has been discussed by various authors. Here, the technique of the Focused Beam Reflectance Measurement (FBRM) is considered as on-line and in-situ measurement device of the CLD of particle dispersions and emulsions. Though useful in general, this measurement cannot be converted directly into a particle size distribution (PSD), unless the physics of the measurement method is described and accounted for. In this work we present a new tool to carry out such a conversion once the particle shape is known a priori and can be fixed, which is based on a two step procedure: (1) the computation of a matrix that converts the PSD of a population of particles with given shape into the corresponding CLD using a 3-dimensional geometric model; (2) the calculation of the PSD from the resulting linear matrix equation for the measured CLD. Here, the method of Projections onto Convex Sets (POCS) is applied to solve the PSD restoration problem, which is a mathematically ill-posed inverse problem. We study the effect of particle shape and matrix dimension on the ill-posed character of the inverse problem. A detailed error analysis of the CLD allows for a predictive description of a posteriori constraints in the POCS framework. We discuss the application of this method to the characterization of simulated test cases and experimentally obtained data.
引用
收藏
页码:81 / 98
页数:18
相关论文
共 50 条
  • [31] Missing microarray data estimation based on projection onto convex sets method
    Gan, XC
    Liew, AWC
    Yan, H
    PROCEEDINGS OF THE 17TH INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION, VOL 3, 2004, : 782 - 785
  • [32] An Improved Weighted Projection Onto Convex Sets Method for Seismic Data Interpolation and Denoising
    Wang, Benfeng
    Chen, Xiaohong
    Li, Jingye
    Cao, Jingjie
    IEEE JOURNAL OF SELECTED TOPICS IN APPLIED EARTH OBSERVATIONS AND REMOTE SENSING, 2016, 9 (01) : 228 - 235
  • [33] Estimation of Chlamydomonas reinhardtii biomass concentration from chord length distribution data
    Lopez-Exposito, Patricio
    Blanco Suarez, Angeles
    Negro, Carlos
    JOURNAL OF APPLIED PHYCOLOGY, 2016, 28 (04) : 2315 - 2322
  • [34] Estimation of Chlamydomonas reinhardtii biomass concentration from chord length distribution data
    Patricio Lopez-Exposito
    Angeles Blanco Suarez
    Carlos Negro
    Journal of Applied Phycology, 2016, 28 : 2315 - 2322
  • [35] General method for the transformation of chord-length data to a local bubble-size distribution
    West Virginia Univ, Morgantown, United States
    AIChE J, 10 (2713-2720):
  • [36] General method for the transformation of chord-length data to a local bubble-size distribution
    Liu, WD
    Clark, NN
    Karamavruc, AI
    AICHE JOURNAL, 1996, 42 (10) : 2713 - 2720
  • [37] Simultaneous interpolation, edge padding and denoising method for gravity data based on the projection onto convex sets
    Zeng X.
    Li X.
    Hou W.
    Liu J.
    Shiyou Diqiu Wuli Kantan/Oil Geophysical Prospecting, 2020, 55 (01): : 197 - 205
  • [38] Tomographic image reconstruction from incomplete projection data by the method of convex projections
    Kudo, Hiroyuki
    Saito, Tsuneo
    Systems and Computers in Japan, 1991, 22 (02) : 66 - 75
  • [39] Fast spectroscopic imaging using online optimal sparse k-space acquisition and projections onto convex sets reconstruction
    Gao, Yun
    Strakowski, Stephen M.
    Reeves, Stanley J.
    Hetherington, Hoby P.
    Chu, Wen-Jang
    Lee, Jing-Huei
    MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (06) : 1265 - 1271
  • [40] Optimization of intensity modulated beams with volume constraints using two methods: Cost function minimization and projections onto convex sets
    Cho, PS
    Lee, S
    Marks, RJ
    Oh, SH
    Sutlief, SG
    Phillips, MH
    MEDICAL PHYSICS, 1998, 25 (04) : 435 - 443