Fast spectroscopic imaging using online optimal sparse k-space acquisition and projections onto convex sets reconstruction

被引:8
|
作者
Gao, Yun
Strakowski, Stephen M.
Reeves, Stanley J.
Hetherington, Hoby P.
Chu, Wen-Jang
Lee, Jing-Huei
机构
[1] Univ Cincinnati, Ctr Imaging Res, Coll Med, Cincinnati, OH 45267 USA
[2] Univ Cincinnati, Coll Med, Dept Psychiat, Cincinnati, OH USA
[3] Univ Cincinnati, Coll Med, Dept Biochem Engn, Cincinnati, OH USA
[4] Auburn Univ, Dept Elect Engn, Auburn, AL 36849 USA
[5] Albert Einstein Coll Med, Dept Radiol, Bronx, NY 10467 USA
[6] Albert Einstein Coll Med, Dept Physiol, Bronx, NY 10467 USA
[7] Albert Einstein Coll Med, Dept Biophys, Bronx, NY 10467 USA
关键词
fast spectroscopic imaging; sequential forward array selection; projections onto convex sets reconstruction; partial k-space sampling; region of support;
D O I
10.1002/mrm.20905
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Long acquisition times, low resolution, and voxel contamination are major difficulties in the application of magnetic resonance spectroscopic imaging (MRSI). To overcome these difficulties, an online-optimized acquisition of k-space, termed sequential forward array selection (SFAS), was developed to reduce acquisition time without sacrificing spatial resolution. A 2D proton MRSI region of interest (ROI) was defined from a scout image and used to create a region of support (ROS) image. The ROS was then used to optimize and obtain a subset of k-space (i.e., a subset of nonuniform phase encodings) and hence reduce the acquisition time for MRSI. Reconstruction and processing software was developed in-house to process and reconstruct MRSI using the projections onto convex sets method. Phantom and in vivo studies showed that good-quality MRS images are obtainable with an approximately 80% reduction of data acquisition time. The reduction of the acquisition time depends on the area ratio of ROS to FOV (i.e., the smaller the ratio, the greater the time reduction). It is also possible to obtain higher-resolution MRS images within a reasonable time using this approach. MRSI with a resolution of 64 x 64 is possible with the acquisition time of the same as 24 x 24 using the traditional full k-space method.
引用
收藏
页码:1265 / 1271
页数:7
相关论文
共 50 条
  • [1] Parallel Spectroscopic Imaging Reconstruction with Arbitrary Trajectories Using k-Space Sparse Matrices
    Gu, Meng
    Liu, Chunlei
    Spielman, Daniel M.
    MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (02) : 267 - 272
  • [2] FAST PROTON SPECTROSCOPIC IMAGING USING THE SLICED K-SPACE METHOD
    NORRIS, DG
    DREHER, W
    MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (05) : 641 - 645
  • [3] Fast keyhole MR imaging using optimized k-space data acquisition
    Sersa, I
    Medic, J
    Beravs, K
    Demsar, F
    ELECTRO- AND MAGNETOBIOLOGY, 1998, 17 (02): : 307 - 321
  • [4] The design of stable, sparse wavefield extrapolators using projections onto convex sets
    Mousa, Wail A.
    GEOPHYSICS, 2013, 78 (01) : T11 - T20
  • [5] Parallel imaging reconstruction for arbitrary trajectories using k-space sparse matrices (kSPA)
    Liu, Chunlei
    Bammer, Roland
    Moseley, Michael E.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (06) : 1171 - 1181
  • [6] Learning Optimal K-space Acquisition and Reconstruction using Physics-Informed Neural Networks
    Peng, Wei
    Feng, Li
    Zhao, Guoying
    Liu, Fang
    2022 IEEE/CVF CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR 2022), 2022, : 20762 - 20771
  • [7] MR image reconstruction of sparsely sampled 3D k-space data by projection-onto-convex sets
    Peng, Haidong
    Sabati, Mohammad
    Lauzon, Louis
    Frayne, Richard
    MAGNETIC RESONANCE IMAGING, 2006, 24 (06) : 761 - 773
  • [8] Impact of Reduced k-Space Acquisition on Pathologic Detectability for Volumetric MR Spectroscopic Imaging
    Sabati, Mohammad
    Zhan, Jiping
    Govind, Varan
    Arheart, Kristopher L.
    Maudsley, Andrew A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (01) : 224 - 234
  • [9] Auto-Calibrated Parallel Imaging Reconstruction for Arbitrary Trajectories Using k-Space Sparse Matrices (kSPA)
    Liu, Chunlei
    Zhang, Jian
    Moseley, Michael E.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (03) : 950 - 959
  • [10] Fast MR Image Reconstruction for Partially Parallel Imaging With Arbitrary k-Space Trajectories
    Ye, Xiaojing
    Chen, Yunmei
    Lin, Wei
    Huang, Feng
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (03) : 575 - 585