Wear analysis in anatomical and reversed shoulder prostheses

被引:8
|
作者
Ribeiro, N. S. [1 ]
Folgado, J. [1 ]
Fernandes, P. R. [1 ]
Monteiro, J. [2 ]
机构
[1] Univ Tecn Lisboa, IDMEC IST, P-1049001 Lisbon, Portugal
[2] Univ Lisbon, Sch Med, P-1649028 Lisbon, Portugal
关键词
total shoulder prostheses; polyethylene wear; shoulder joint; finite element models; POLYETHYLENE WEAR; GLENOID COMPONENT; BONE; ARTHROPLASTY; COMPLICATIONS; OSTEOLYSIS; STRENGTH; BEHAVIOR; GEOMETRY; CONTACT;
D O I
10.1080/10255842.2010.499868
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
This paper describes the development of a computational model to calculate wear rates in total shoulder prostheses, for a 5-150 degrees arm abduction. Anatomical keeled and pegged prosthesis as well as reversed prosthesis were the studied implants. The bone models were built based on computed tomography (CT) images and using a computer aided design-based modelling pipeline. The finite element method was used to solve the contact problem between the surface of the polyethylene (PE) components and the corresponding articular component. The aim of this work was to determine linear and volumetric PE wear, for several radial mismatches, in conditions of pathological (rheumatoid arthritis) and non-pathological bone. Results showed that contact pressures and linear wear developed in anatomical prosthesis were higher than those visualised in reversed prosthesis. However, anatomical prosthesis exhibited a better volumetric wear performance. Moreover, our findings indicated higher values of volumetric wear in higher congruent models and on pathological bone conditions.
引用
收藏
页码:883 / 892
页数:10
相关论文
共 50 条
  • [31] REPLACEMENT PROSTHESES IN SHOULDER INJURIES
    GILFILLAN, C
    AMERICAN JOURNAL OF SURGERY, 1956, 91 (06): : 900 - 905
  • [32] Geometrical analysis of stemless shoulder arthroplasty: a radiological study of seventy TESS total shoulder prostheses
    Bakir Kadum
    Hamid Hassany
    Mats Wadsten
    Arkan Sayed-Noor
    Göran Sjödén
    International Orthopaedics, 2016, 40 : 751 - 758
  • [33] Geometrical analysis of stemless shoulder arthroplasty: a radiological study of seventy TESS total shoulder prostheses
    Kadum, Bakir
    Hassany, Hamid
    Wadsten, Mats
    Sayed-Noor, Arkan
    Sjoden, Goran
    INTERNATIONAL ORTHOPAEDICS, 2016, 40 (04) : 751 - 758
  • [34] WEAR ANALYSIS OF RETRIEVED ALUMINA HEADS AND SOCKETS OF HIP PROSTHESES
    DORLOT, JM
    CHRISTEL, P
    MEUNIER, A
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH-APPLIED BIOMATERIALS, 1989, 23 (A3): : 299 - 310
  • [35] WALKING ACTIVITIES AND WEAR OF PROSTHESES
    SEEDHOM, BB
    WALLBRIDGE, NC
    ANNALS OF THE RHEUMATIC DISEASES, 1985, 44 (12) : 838 - 843
  • [36] Fixation of the reversed shoulder prosthesis
    Hopkins, Andrew R.
    Hansen, Ulrich N.
    Bull, Anthony M. J.
    Emery, Roger
    Amis, Andrew A.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2008, 17 (06) : 974 - 980
  • [37] Wear of bipolar hip prostheses
    Kusaba, A
    Kuroki, Y
    JOURNAL OF ARTHROPLASTY, 1998, 13 (06): : 668 - 673
  • [38] Wear-induced loss of mass in reversed total shoulder arthroplasty with conventional and inverted bearing materials
    Kohut, Georges
    Dallmann, Frank
    Irlenbusch, Ulrich
    JOURNAL OF BIOMECHANICS, 2012, 45 (03) : 469 - 473
  • [39] Options and limits of stemless shoulder prostheses
    Ambacher, T.
    ORTHOPADE, 2013, 42 (07): : 495 - 500
  • [40] Total prostheses in degenerative shoulder pathology
    Augereau, B.
    E-MEMOIRES DE L ACADEMIE NATIONALE DE CHIRURGIE, 2010, 9 (02): : 69 - 75